Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Diagnostics, MDPI AG, Vol. 13, No. 7 ( 2023-03-25), p. 1237-
    Abstract: Background: The aim of this study was to assess the phenotype of multifocal motor neuropathy (MMN) and amyotrophic lateral sclerosis (ALS) in quantitative MR neurography. Methods: In this prospective study, 22 patients with ALS, 8 patients with MMN, and 10 healthy volunteers were examined with 3T MR neurography, using a high-resolution fat-saturated T2-weighted sequence, diffusion-tensor imaging (DTI), and a multi-echo T2-relaxometry sequence. The quantitative biomarkers fractional anisotropy (FA), radial and axial diffusivity (RD, AD), mean diffusivity (MD), cross-sectional area (CSA), T2-relaxation time, and proton spin density (PSD) were measured in the tibial nerve at the thigh and calf, and in the median, radial, and ulnar nerves at the mid-upper arm. Results: MMN showed a characteristic imaging pattern of decreased FA (p = 0.018), increased RD (p = 0.014), increased CSA (p 〈 0.001), increased T2-relaxation time (p 〈 0.001), and increased PSD (p = 0.025) in the upper arm nerves compared to ALS and controls. ALS patients did not differ from controls in any imaging marker, nor were there any group differences in the tibial nerve (p 〉 0.05). Conclusions: MMN shows a characteristic pattern of quantitative DTI and T2-relaxometry parameters in the upper-arm nerves, primarily indicating demyelination. Peripheral nerve changes in ALS seem to be below the detection level of current state-of-the-art quantitative MR neurography.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: Diagnostics, MDPI AG, Vol. 12, No. 4 ( 2022-03-23), p. 780-
    Abstract: Purpose To examine the spatial distribution and long-term alterations of peripheral nerve lesions in patients with schwannomatosis by in vivo high-resolution magnetic resonance neurography (MRN). Methods In this prospective study, the lumbosacral plexus as well as the right sciatic, tibial, and peroneal nerves were examined in 15 patients diagnosed with schwannomatosis by a standardized MRN protocol at 3 Tesla. Micro-, intermediate- and macrolesions were assessed according to their number, diameter and spatial distribution. Moreover, in nine patients, peripheral nerve lesions were compared to follow-up examinations after 39 to 71 months. Results In comparison to intermediate and macrolesions, microlesions were the predominant lesion entity at the level of the proximal (p 〈 0.001), mid- (p 〈 0.001), and distal thigh (p 〈 0.01). Compared to the proximal calf level, the lesion number was increased at the proximal (p 〈 0.05), mid- (p 〈 0.01), and distal thigh level (p 〈 0.01), while between the different thigh levels, no differences in lesion numbers were found. In the follow-up examinations, the lesion number was unchanged for micro-, intermediate and macrolesions. The diameter of lesions in the follow-up examination was decreased for microlesions (p 〈 0.01), not different for intermediate lesions, and increased for macrolesions (p 〈 0.01). Conclusion Microlesions represent the predominant type of peripheral nerve lesion in schwannomatosis and show a rather consistent distribution pattern in long-term follow-up. In contrast to the accumulation of nerve lesions, primarily in the distal nerve segments in NF2, the lesion numbers in schwannomatosis peak at the mid-thigh level. Towards more distal portions, the lesion number markedly decreases, which is considered as a general feature of other types of small fiber neuropathy.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    In: Journal of Clinical Medicine, MDPI AG, Vol. 10, No. 23 ( 2021-11-26), p. 5546-
    Abstract: This study aimed to investigate the geometric reproducibility of three-dimensional (3D) implant planning based on magnetic resonance imaging (MRI) and cone-beam computed tomography (CBCT). Four raters used a backward-planning approach based on CBCT imaging and standard software to position 41 implants in 27 patients. Implant planning was repeated, and the first and second plans were analyzed for geometric differences regarding implant tip, entry-level, and axis. The procedure was then repeated for MRI data of the same patients. Thus, 656 implant plans were available for analysis of intra-rater reproducibility. For both imaging modalities, the second-round 3D implant plans were re-evaluated regarding inter-rater reproducibility. Differences between the modalities were analyzed using paired t-tests. Intra- and inter-rater reproducibility were higher for CBCT than for MRI. Regarding intra-rater deviations, mean values for MRI were 1.7 ± 1.1 mm/1.5 ± 1.1 mm/5.5 ± 4.2° at implant tip/entry-level/axis. For CBCT, corresponding values were 1.3 ± 0.8 mm/1 ± 0.6 mm/4.5 ± 3.1°. Inter-rater comparisons revealed mean values of 2.2 ± 1.3 mm/1.7 ± 1 mm/7.5 ± 4.9° for MRI, and 1.7 ± 1 mm/1.2 ± 0.7 mm/6 ± 3.7° for CBCT. CBCT-based implant planning was more reproducible than MRI. Nevertheless, more research is needed to increase planning reproducibility—for both modalities—thereby standardizing 3D implant planning.
    Type of Medium: Online Resource
    ISSN: 2077-0383
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2662592-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    In: Cancers, MDPI AG, Vol. 15, No. 3 ( 2023-02-02), p. 965-
    Abstract: Purpose: This study investigates the impact of different intensity normalization (IN) methods on the overall survival (OS) radiomics models’ performance of MR sequences in primary (pHGG) and recurrent high-grade glioma (rHGG). Methods: MR scans acquired before radiotherapy were retrieved from two independent cohorts (rHGG C1: 197, pHGG C2: 141) from multiple scanners (15, 14). The sequences are T1 weighted (w), contrast-enhanced T1w (T1wce), T2w, and T2w-FLAIR. Sequence-specific significant features (SF) associated with OS, extracted from the tumour volume, were derived after applying 15 different IN methods. Survival analyses were conducted using Cox proportional hazard (CPH) and Poisson regression (POI) models. A ranking score was assigned based on the 10-fold cross-validated (CV) concordance index (C-I), mean square error (MSE), and the Akaike information criterion (AICs), to evaluate the methods’ performance. Results: Scatter plots of the 10-CV C-I and MSE against the AIC showed an impact on the survival predictions between the IN methods and MR sequences (C1/C2 C-I range: 0.62–0.71/0.61–0.72, MSE range: 0.20–0.42/0.13–0.22). White stripe showed stable results for T1wce (C1/C2 C-I: 0.71/0.65, MSE: 0.21/0.14). Combat (0.68/0.62, 0.22/0.15) and histogram matching (HM, 0.67/0.64, 0.22/0.15) showed consistent prediction results for T2w models. They were also the top-performing methods for T1w in C2 (Combat: 0.67, 0.13; HM: 0.67, 0.13); however, only HM achieved high predictions in C1 (0.66, 0.22). After eliminating IN impacted SF using Spearman’s rank-order correlation coefficient, a mean decrease in the C-I and MSE of 0.05 and 0.03 was observed in all four sequences. Conclusion: The IN method impacted the predictive power of survival models; thus, performance is sequence-dependent.
    Type of Medium: Online Resource
    ISSN: 2072-6694
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2527080-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    In: Cancers, MDPI AG, Vol. 15, No. 6 ( 2023-03-17), p. 1820-
    Abstract: Background: MR image classification in datasets collected from multiple sources is complicated by inconsistent and missing DICOM metadata. Therefore, we aimed to establish a method for the efficient automatic classification of MR brain sequences. Methods: Deep convolutional neural networks (DCNN) were trained as one-vs-all classifiers to differentiate between six classes: T1 weighted (w), contrast-enhanced T1w, T2w, T2w-FLAIR, ADC, and SWI. Each classifier yields a probability, allowing threshold-based and relative probability assignment while excluding images with low probability (label: unknown, open-set recognition problem). Data from three high-grade glioma (HGG) cohorts was assessed; C1 (320 patients, 20,101 MRI images) was used for training, while C2 (197, 11,333) and C3 (256, 3522) were for testing. Two raters manually checked images through an interactive labeling tool. Finally, MR-Class’ added value was evaluated via radiomics model performance for progression-free survival (PFS) prediction in C2, utilizing the concordance index (C-I). Results: Approximately 10% of annotation errors were observed in each cohort between the DICOM series descriptions and the derived labels. MR-Class accuracy was 96.7% [95% Cl: 95.8, 97.3] for C2 and 94.4% [93.6, 96.1] for C3. A total of 620 images were misclassified; manual assessment of those frequently showed motion artifacts or alterations of anatomy by large tumors. Implementation of MR-Class increased the PFS model C-I by 14.6% on average, compared to a model trained without MR-Class. Conclusions: We provide a DCNN-based method for the sequence classification of brain MR images and demonstrate its usability in two independent HGG datasets.
    Type of Medium: Online Resource
    ISSN: 2072-6694
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2527080-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    In: Diagnostics, MDPI AG, Vol. 10, No. 12 ( 2020-11-30), p. 1027-
    Abstract: The purpose of this study is to examine alterations of the peripheral nervous system (PNS) in oligo-symptomatic patients carrying the Fabry related GLA-gene variant p.A143T by Magnetic Resonance Neurography (MRN) and skin biopsy. This prospective study assessed dorsal root ganglia (DRG) volume L3 to S2, vascular permeability of the DRG L5, S1, and the spinal nerve L5 in five patients carrying p.A143T in comparison to patients with classical Fabry mutations and healthy controls. Moreover, skin punch biopsies above the lateral malleolus of the right foot were obtained in four patients and intraepidermal nerve fiber density (IENFD) was counted individually. Compared to controls, DRG volumes of p.A143T patients were enlarged by 30% (L3, p 〈 0.05), 35% (L4, p 〈 0.05), 29% (L5, p = 0.15), 36% (S1, p 〈 0.01), and 18% (S2, p 〈 0.05), but less pronounced compared to patients carrying a classical Fabry mutation. Compared to healthy controls, vascular permeability was decreased by 40% (L5 right), 49% (L5 left), 48% (S1 right), and 49% (S1) (p 〈 0.01–p 〈 0.001), but non-significant less than patients carrying a classical Fabry mutation. Compared to sex-matched 5% lower normative reference values per decade, IENFD was decreased in three of four patients. MRN and determination of IENFD is able to detect early alteration of the PNS segment in oligo-symptomatic patients with the disease-modifying GLA-variant p.A143T on an individual basis. This procedure might also help in further GLA-variants of uncertain significance for early identification of patients with single major organ manifestation.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2020
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    In: Diagnostics, MDPI AG, Vol. 12, No. 7 ( 2022-06-28), p. 1570-
    Abstract: Background: Dorsal root ganglia (DRG) volume assessment by MR-Neurography (MRN) has evolved to an important imaging marker in the diagnostic workup of various peripheral neuropathies and pain syndromes. The aim of this study was (1) to assess normal values of DRG volume and correlations with demographic determinants and (2) to quantify the inter-reader and inter-method reliability of three different methods of DRG volumetry. Methods: Sixty healthy subjects (mean age: 59.1, range 23–79) were examined using a 3D T2-weighted MRN of the lumbosacral plexus at 3 Tesla. Normal values of DRG L3 to S2 were obtained after exact volumetry based on manual 3D segmentation and correlations with demographic variables were assessed. For the assessment of inter-reader and inter-method reliability, DRG volumes in a subset of 25 participants were measured by two independent readers, each applying (1) exact volumetry based on 3D segmentation, (2) axis-corrected, and (3) non-axis-corrected volume estimation. Intraclass correlation coefficients were reported and the Bland–Altman analysis was conducted. Results: Mean DRG volumes ranged from 124.8 mm3 for L3 to 323.3 mm3 for S1 and did not differ between right and left DRG. DRG volume (mean of L3 to S1) correlated with body height (r = 0.42; p = 0.0008) and weight (r = 0.34; p = 0.0087). DRG of men were larger than of women (p = 0.0002); however, no difference remained after correction for body height. Inter-reader reliability was high for all three methods but best for exact volumetry (ICC = 0.99). While axis-corrected estimation was not associated with a relevant bias, non-axis-corrected estimation systematically overestimated DRG volume by on average of 15.55 mm3 (reader 1) or 18.00 mm3 (reader 2) when compared with exact volumetry. Conclusion: The here presented normal values of lumbosacral DRG volume and the correlations with height and weight may be considered in future disease specific studies and possible clinical applications. Exact volumetry was most reliable and should be considered the gold standard. However, the reliability of axis-corrected and non-axis-corrected volume estimation was also high and might still be sufficient, depending on the degree of the required measurement accuracy.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages