Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Journal of Imaging, MDPI AG, Vol. 9, No. 3 ( 2023-03-09), p. 65-
    Abstract: We compared the image quality and quantification parameters through bayesian penalized likelihood reconstruction algorithm (Q.Clear) and ordered subset expectation maximization (OSEM) algorithm for 2-[18F]FDG-PET/CT scans performed for response monitoring in patients with metastatic breast cancer in prospective setting. We included 37 metastatic breast cancer patients diagnosed and monitored with 2-[18F] FDG-PET/CT at Odense University Hospital (Denmark). A total of 100 scans were analyzed blinded toward Q.Clear and OSEM reconstruction algorithms regarding image quality parameters (noise, sharpness, contrast, diagnostic confidence, artefacts, and blotchy appearance) using a five-point scale. The hottest lesion was selected in scans with measurable disease, considering the same volume of interest in both reconstruction methods. SULpeak (g/mL) and SUVmax (g/mL) were compared for the same hottest lesion. There was no significant difference regarding noise, diagnostic confidence, and artefacts within reconstruction methods; Q.Clear had significantly better sharpness (p 〈 0.001) and contrast (p = 0.001) than the OSEM reconstruction, while the OSEM reconstruction had significantly less blotchy appearance compared with Q.Clear reconstruction (p 〈 0.001). Quantitative analysis on 75/100 scans indicated that Q.Clear reconstruction had significantly higher SULpeak (5.33 ± 2.8 vs. 4.85 ± 2.5, p 〈 0.001) and SUVmax (8.27 ± 4.8 vs. 6.90 ± 3.8, p 〈 0.001) compared with OSEM reconstruction. In conclusion, Q.Clear reconstruction revealed better sharpness, better contrast, higher SUVmax, and higher SULpeak, while OSEM reconstruction had less blotchy appearance.
    Type of Medium: Online Resource
    ISSN: 2313-433X
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2824270-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: Cancers, MDPI AG, Vol. 13, No. 16 ( 2021-08-13), p. 4080-
    Abstract: We compared response categories and impacts on treatment decisions for metastatic breast cancer (MBC) patients that are response-monitored with contrast-enhanced computed-tomography (CE-CT) or fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT). A comparative diagnostic study was performed on MBC patients undergoing response monitoring by CE-CT (n = 34) or FDG-PET/CT (n = 31) at the Odense University Hospital (Denmark). The responses were assessed visually and allocated into categories of complete response (CR/CMR), partial response (PR/PMR), stable disease (SD/SMD), and progressive disease (PD/PMD). Response categories, clinical impact, and positive predictive values (PPV) were compared for follow-up scans. A total of 286 CE-CT and 189 FDG-PET/CT response monitoring scans were performed. Response categories were distributed into CR (3.8%), PR (8.4%), SD (70.6%), PD (15%), and others (2.1%) by CE-CT and into CMR (22.2%), PMR (23.8%), SMD (31.2%), PMD (18.5%), and others (4.4%) by FDG-PET/CT, revealing a significant difference between the groups (P 〈 0.001). PD and PMD caused changes of treatment in 79.1% and 60%, respectively (P = 0.083). PPV for CE-CT and FDG-PET/CT was 0.85 (95% CI: 0.72–0.97) and 0.70 (95% CI: 0.53–0.87), respectively (P = 0.17). FDG-PET/CT indicated regression of disease more frequently than CE-CT, while CE-CT indicated stable disease more often. FDG-PET/CT seems to be more sensitive than CE-CT for monitoring response in metastatic breast cancer.
    Type of Medium: Online Resource
    ISSN: 2072-6694
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2527080-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    In: Diagnostics, MDPI AG, Vol. 11, No. 4 ( 2021-04-19), p. 723-
    Abstract: Background: We aimed to examine the feasibility and potential benefit of applying PET Response Criteria in Solid Tumors (PERCIST) for response monitoring in metastatic breast cancer (MBC). Further, we introduced the nadir scan as a reference. Methods: Response monitoring FDG-PET/CT scans in 37 women with MBC were retrospectively screened for PERCIST standardization and measurability criteria. One-lesion PERCIST based on changes in SULpeak measurements of the hottest metastatic lesion was used for response categorization. The baseline (PERCISTbaseline) and the nadir scan (PERCISTnadir) were used as references for PERCIST analyses. Results: Metastatic lesions were measurable according to PERCIST in 35 of 37 (94.7%) patients. PERCIST was applied in 150 follow-up scans, with progression more frequently reported by PERCISTnadir (36%) than PERCISTbaseline (29.3%; p = 0.020). Reasons for progression were (a) more than 30% increase in SULpeak of the hottest lesion (n = 7, 15.9%), (b) detection of new metastatic lesions (n = 28, 63.6%), or both (a) and (b) (n = 9, 20.5%). Conclusions: PERCIST, with the introduction of PERCISTnadir, allows a graphical interpretation of disease fluctuation that may be beneficial in clinical decision-making regarding potential earlier termination of non-effective toxic treatment. PERCIST seems feasible for response monitoring in MBC but prospective studies are needed to come this closer.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    In: Journal of Imaging, MDPI AG, Vol. 9, No. 9 ( 2023-08-31), p. 178-
    Abstract: We investigated the impact of 2-[18F]FDG-PET/CT on detection rate (DR) of the primary tumor and survival in patients with suspected cancer of unknown primary tumor (CUP), comparing it to the conventional diagnostic imaging method, CT. Patients who received a tentative CUP diagnosis at Odense University Hospital from 2014–2017 were included. Patients receiving a 2-[18F] FDG-PET/CT were assigned to the 2-[18F]FDG-PET/CT group and patients receiving a CT only to the CT group. DR was calculated as the proportion of true positive findings of 2-[18F] FDG-PET/CT and CT scans, separately, using biopsy of the primary tumor, autopsy, or clinical decision as reference standard. Survival analyses included Kaplan–Meier estimates and Cox proportional hazards regression adjusted for age, sex, treatment, and propensity score. We included 193 patients. Of these, 159 were in the 2-[18F]FDG-PET/CT group and 34 were in the CT group. DR was 36.5% in the 2-[18F] FDG-PET/CT group and 17.6% in the CT group, respectively (p = 0.012). Median survival was 7.4 (95% CI 0.4–98.7) months in the 2-[18F]FDG-PET/CT group and 3.8 (95% CI 0.2–98.1) in the CT group. Survival analysis showed a crude hazard ratio of 0.63 (p = 0.024) and an adjusted hazard ratio of 0.68 (p = 0.087) for the 2-[18F] FDG-PET/CT group compared with CT. This study found a significantly higher DR of the primary tumor in suspected CUP patients using 2-[18F]FDG-PET/CT compared with patients receiving only CT, with possible immense clinical importance. No significant difference in survival was found, although a possible tendency towards longer survival in the 2-[18F] FDG-PET/CT group was observed.
    Type of Medium: Online Resource
    ISSN: 2313-433X
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2824270-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    In: Diagnostics, MDPI AG, Vol. 9, No. 3 ( 2019-08-27), p. 106-
    Abstract: 18F-fluorodeoxyglucose positron emission tomography with integrated computed tomography (FDG-PET/CT) and contrast-enhanced computed tomography (CT) can be used for response evaluation in metastatic breast cancer (MBC). In this study, we aimed to review literature comparing the PET Response Criteria in Solid Tumors (PERCIST) with Response Evaluation Criteria in Solid Tumors (RECIST) in patients with MBC. We made a systematic search in Embase, PubMed/Medline, and Cochrane Library using a modified PICO model. The population was MBC patients and the intervention was PERCIST or RECIST. Quality assessment was performed using the QUADAS-2 checklist. A total of 1975 articles were identified. After screening by title/abstract, 78 articles were selected for further analysis of which 2 duplicates and 33 abstracts/out of focus articles were excluded. The remaining 43 articles provided useful information, but only one met the inclusion and none of the exclusion criteria. This was a retrospective study of 65 patients with MBC showing one-year progression-free survival for responders versus non-responders to be 59% vs. 27% (p = 0.2) by RECIST compared to 64% vs. 0% (p = 0.0001) by PERCIST. This systematic literature review identified a lack of studies comparing the use of RECIST (with CE-CT) and PERCIST (with FDG-PET/CT) for response evaluation in metastatic breast cancer. The available sparse literature suggests that PERCIST might be more appropriate than RECIST for predicting prognosis in patients with MBC.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2019
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages