    American Diabetes Association ; 1981
    In:  Diabetes Care Vol. 4, No. 3 ( 1981-05-01), p. 414-416
    In: Diabetes Care, American Diabetes Association, Vol. 4, No. 3 ( 1981-05-01), p. 414-416
    Abstract: We studied the reliability of the Chemstrip system in the self-monitoring of blood glucose by diabetic patients. A total of 453 blood glucose values obtained by 38 diabetic patients using Chemstrip were compared with the glucose values of the same blood samples measured with a conventional laboratory method. We found a definite tendency at concentrations & lt;320 mg/dl for patient-read Chemstrip values to be too low. Also, we found a wide range in laboratory values corresponding to a given patient-read Chemstrip value. However, a better agreement between Chemstrip and laboratory values was obtained when the Chemstrips were read by trained staff. We recommend, therefore, that the use of Chemstrip in the self-monitoring of blood glucose can be restricted to patients who have shown competence in the use of Chemstrip during prior testing.
    Type of Medium: Online Resource
    ISSN: 0149-5992 , 1935-5548
    Language: English
    Publisher: American Diabetes Association
    Publication Date: 1981
    detail.hit.zdb_id: 1490520-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    American Diabetes Association ; 1983
    In:  Diabetes Care Vol. 6, No. 5 ( 1983-09-01), p. 459-462
    In: Diabetes Care, American Diabetes Association, Vol. 6, No. 5 ( 1983-09-01), p. 459-462
    Abstract: The effect of injection technique on the absorption of subcutaneously injected short-acting insulin [125I labeled Actrapid (MC), Novo, Copenhagen, Denmark] was investigated in insulin-dependent diabetic patients. In one side of the abdomen insulin was given with a fixed standard technique. In the other side of the abdomen the temperature of the injected insulin, the depth of injection, and the duration of injection were varied. Furthermore, we compared the absorption of U40 and U100 insulin by giving either 8 U of the two insulins or 0.1 ml of both insulins simultaneously to the patients in either side of the abdomen. With regard to the injection technique the only significant finding was a faster absorption rate with deep (12 mm) than with superficial (3 mm) injection. The absorption of U100 insulin was significantly slower than of U40 insulin, when given in the same amount (8 U) as well as in the same volume (0.1 ml).
    Type of Medium: Online Resource
    ISSN: 0149-5992 , 1935-5548
    Language: English
    Publisher: American Diabetes Association
    Publication Date: 1983