In:
Journal of Athletic Training, Journal of Athletic Training/NATA, Vol. 58, No. 2 ( 2023-02-01), p. 97-105
Abstract:
The King-Devick (K-D) test is used to identify oculomotor impairment after concussion. However, the diagnostic accuracy of the K-D test over time has not been evaluated. Objectives To (1) examine the sensitivity and specificity of the K-D test at 0 to 6 hours postinjury, 24 to 48 hours postinjury, the beginning of a return-to-play (RTP) protocol (asymptomatic), unrestricted RTP, and 6 months postconcussion and (2) compare outcomes between athletes with and those without concussion across confounding factors (sex, age, sport contact level, academic year, learning disorder, attention-deficit/hyperactivity disorder, migraine history, concussion history, and test administration mode). Design Retrospective, cross-sectional design. Setting Multiple institutions in the Concussion Assessment, Research and Education Consortium. Patients or Other Participants A total of 320 athletes with a concussion (162 men, 158 women; age = 19.80 ± 1.41 years) were compared with 1239 total collegiate athletes without a concussion (646 men, 593 women; age = 20.31 ± 1.18 years). Main Outcome Measure(s) We calculated the K-D test time difference (in seconds) by subtracting the baseline from the most recent time. Receiver operator characteristic (ROC) curve and area under the curve (AUC) analyses were used to determine the diagnostic accuracy across time points. We identified cutoff scores and corresponding specificity at both the 80% and 70% sensitivity levels. We repeated ROC with AUC analyses using confounding factors. Results The K-D test predicted positive results at the 0- to 6-hour (AUC = 0.724, P & lt; .001), 24- to 48-hour (AUC = 0.701, P & lt; .001), RTP (AUC = 0.640, P & lt; .001), and 6-month postconcussion (AUC = 0.615, P & lt; .001) tim points but not at the asymptomatic time point (AUC = 0.513, P = .497). The 0- to 6-hour and 24- to 48-hour time points yielded 80% sensitivity cutoff scores of −2.6 and −3.2 seconds (ie, faster), respectively, but 46% and 41% specificity, respectively. The K-D test had a better AUC when administered using an iPad (AUC = 0.800, 95% CI = 0.747, 0.854) compared with the spiral-bound card system (AUC = 0.646, 95% CI = 0.600, 0.692; P & lt; .001). Conclusions The diagnostic accuracy of the K-D test was greatest at 0 to 6 hours and 24 to 48 hours postconcussion but declined across subsequent postconcussion time points. The AUCs did not differentiate between groups across confounding factors. Our negative cutoff scores indicated that practice effects contributed to improved performance, requiring athletes to outperform their baseline scores.
Type of Medium:
Online Resource
ISSN:
1938-162X
,
1062-6050
DOI:
10.4085/1062-6050-0063.21
Language:
English
Publisher:
Journal of Athletic Training/NATA
Publication Date:
2023
detail.hit.zdb_id:
2070051-9
SSG:
31
Bookmarklink