Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Journal of Imaging, MDPI AG, Vol. 9, No. 3 ( 2023-03-09), p. 65-
    Abstract: We compared the image quality and quantification parameters through bayesian penalized likelihood reconstruction algorithm (Q.Clear) and ordered subset expectation maximization (OSEM) algorithm for 2-[18F]FDG-PET/CT scans performed for response monitoring in patients with metastatic breast cancer in prospective setting. We included 37 metastatic breast cancer patients diagnosed and monitored with 2-[18F] FDG-PET/CT at Odense University Hospital (Denmark). A total of 100 scans were analyzed blinded toward Q.Clear and OSEM reconstruction algorithms regarding image quality parameters (noise, sharpness, contrast, diagnostic confidence, artefacts, and blotchy appearance) using a five-point scale. The hottest lesion was selected in scans with measurable disease, considering the same volume of interest in both reconstruction methods. SULpeak (g/mL) and SUVmax (g/mL) were compared for the same hottest lesion. There was no significant difference regarding noise, diagnostic confidence, and artefacts within reconstruction methods; Q.Clear had significantly better sharpness (p 〈 0.001) and contrast (p = 0.001) than the OSEM reconstruction, while the OSEM reconstruction had significantly less blotchy appearance compared with Q.Clear reconstruction (p 〈 0.001). Quantitative analysis on 75/100 scans indicated that Q.Clear reconstruction had significantly higher SULpeak (5.33 ± 2.8 vs. 4.85 ± 2.5, p 〈 0.001) and SUVmax (8.27 ± 4.8 vs. 6.90 ± 3.8, p 〈 0.001) compared with OSEM reconstruction. In conclusion, Q.Clear reconstruction revealed better sharpness, better contrast, higher SUVmax, and higher SULpeak, while OSEM reconstruction had less blotchy appearance.
    Type of Medium: Online Resource
    ISSN: 2313-433X
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2824270-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: Cancers, MDPI AG, Vol. 13, No. 16 ( 2021-08-13), p. 4080-
    Abstract: We compared response categories and impacts on treatment decisions for metastatic breast cancer (MBC) patients that are response-monitored with contrast-enhanced computed-tomography (CE-CT) or fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT). A comparative diagnostic study was performed on MBC patients undergoing response monitoring by CE-CT (n = 34) or FDG-PET/CT (n = 31) at the Odense University Hospital (Denmark). The responses were assessed visually and allocated into categories of complete response (CR/CMR), partial response (PR/PMR), stable disease (SD/SMD), and progressive disease (PD/PMD). Response categories, clinical impact, and positive predictive values (PPV) were compared for follow-up scans. A total of 286 CE-CT and 189 FDG-PET/CT response monitoring scans were performed. Response categories were distributed into CR (3.8%), PR (8.4%), SD (70.6%), PD (15%), and others (2.1%) by CE-CT and into CMR (22.2%), PMR (23.8%), SMD (31.2%), PMD (18.5%), and others (4.4%) by FDG-PET/CT, revealing a significant difference between the groups (P 〈 0.001). PD and PMD caused changes of treatment in 79.1% and 60%, respectively (P = 0.083). PPV for CE-CT and FDG-PET/CT was 0.85 (95% CI: 0.72–0.97) and 0.70 (95% CI: 0.53–0.87), respectively (P = 0.17). FDG-PET/CT indicated regression of disease more frequently than CE-CT, while CE-CT indicated stable disease more often. FDG-PET/CT seems to be more sensitive than CE-CT for monitoring response in metastatic breast cancer.
    Type of Medium: Online Resource
    ISSN: 2072-6694
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2527080-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    In: Diagnostics, MDPI AG, Vol. 10, No. 6 ( 2020-06-11), p. 398-
    Abstract: This study aimed to compare the prognostic value of quantitative measures of [18F]-fluorodeoxyglucose positron emission tomography with integrated computed tomography (FDG-PET/CT) for the response monitoring of patients with metastatic breast cancer (MBC). In this prospective study, 22 patients with biopsy-verified MBC diagnosed between 2011 and 2014 at Odense University Hospital (Denmark) were followed up until 2019. A dual-time-point FDG-PET/CT scan protocol (1 and 3 h) was applied at baseline, when MBC was diagnosed. Baseline characteristics and quantitative measures of maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), corrected SUVmean (cSUVmean), metabolic tumor volume (MTV), total lesion glycolysis (TLG), and corrected TLG (cTLG) were collected. Survival time was analyzed using the Kaplan–Meier method and was regressed on MTV, TLG, and cTLG while adjusting for clinicopathological characteristics. Among the 22 patients included (median age: 59.5 years), 21 patients (95%) died within the follow-up period. Median survival time was 29.13 months (95% Confidence interval: 20.4–40 months). Multivariable Cox proportional hazards regression analyses of survival time showed no influence from the SUVmean, cSUVmean, or SUVmax, while increased values of MTV, TLG, and cTLG were significantly associated with slightly higher risk, with hazard ratios ranging between 1.0003 and 1.004 (p = 0.007 to p = 0.026). Changes from 1 to 3 h were insignificant for all PET measures in the regression model. In conclusion, MTV and TLG are potential prognostic markers for overall survival in MBC patients.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2020
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    In: Diagnostics, MDPI AG, Vol. 11, No. 4 ( 2021-04-19), p. 723-
    Abstract: Background: We aimed to examine the feasibility and potential benefit of applying PET Response Criteria in Solid Tumors (PERCIST) for response monitoring in metastatic breast cancer (MBC). Further, we introduced the nadir scan as a reference. Methods: Response monitoring FDG-PET/CT scans in 37 women with MBC were retrospectively screened for PERCIST standardization and measurability criteria. One-lesion PERCIST based on changes in SULpeak measurements of the hottest metastatic lesion was used for response categorization. The baseline (PERCISTbaseline) and the nadir scan (PERCISTnadir) were used as references for PERCIST analyses. Results: Metastatic lesions were measurable according to PERCIST in 35 of 37 (94.7%) patients. PERCIST was applied in 150 follow-up scans, with progression more frequently reported by PERCISTnadir (36%) than PERCISTbaseline (29.3%; p = 0.020). Reasons for progression were (a) more than 30% increase in SULpeak of the hottest lesion (n = 7, 15.9%), (b) detection of new metastatic lesions (n = 28, 63.6%), or both (a) and (b) (n = 9, 20.5%). Conclusions: PERCIST, with the introduction of PERCISTnadir, allows a graphical interpretation of disease fluctuation that may be beneficial in clinical decision-making regarding potential earlier termination of non-effective toxic treatment. PERCIST seems feasible for response monitoring in MBC but prospective studies are needed to come this closer.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    In: Diagnostics, MDPI AG, Vol. 10, No. 12 ( 2020-11-24), p. 1001-
    Abstract: Response evaluation at regular intervals is indicated for treatment of metastatic breast cancer (MBC). FDG-PET/CT has the potential to monitor treatment response accurately. Our purpose was to: (a) compare the interrater agreement and reliability of the semi-quantitative PERCIST criteria to qualitative visual assessment in response evaluation of MBC and (b) investigate the intrarater agreement when comparing visual assessment of each rater to their respective PERCIST assessment. We performed a retrospective study on FDG-PET/CT in women who received treatment for MBC. Three specialists in nuclear medicine categorized response evaluation by qualitative assessment and standardized one-lesion PERCIST assessment. The scans were categorized into complete metabolic response, partial metabolic response, stable metabolic disease, and progressive metabolic disease. 37 patients with 179 scans were included. Visual assessment categorization yielded moderate agreement with an overall proportion of agreement (PoA) between raters of 0.52 (95% CI 0.44–0.66) and a Fleiss kappa estimate of 0.54 (95% CI 0.46–0.62). PERCIST response categorization yielded substantial agreement with an overall PoA of 0.65 (95% CI 0.57–0.73) and a Fleiss kappa estimate of 0.68 (95% CI 0.60–0.75). The difference in PoA between overall estimates for PERCIST and visual assessment was 0.13 (95% CI 0.06–0.21; p = 0.001), that of kappa was 0.14 (95% CI 0.06–0.21; p 〈 0.001). The overall intrarater PoA was 0.80 (95% CI 0.75–0.84) with substantial agreement by a Fleiss kappa of 0.74 (95% CI 0.69–0.79). Semi-quantitative PERCIST assessment achieved significantly higher level of overall agreement and reliability compared with qualitative assessment among three raters. The achieved high levels of intrarater agreement indicated no obvious conflicting elements between the two methods. PERCIST assessment may, therefore, give more consistent interpretations between raters when using FDG-PET/CT for response evaluation in MBC.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2020
    detail.hit.zdb_id: 2662336-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages