In:
The American Journal of Sports Medicine, SAGE Publications, Vol. 39, No. 12 ( 2011-12), p. 2558-2565
Abstract:
Background: The Cartilage Regeneration System (CaReS) is a novel matrix-associated autologous chondrocyte implantation (ACI) technique for the treatment of chondral and osteochondral lesions (Outerbridge grades III and IV). For this technology, no expansion of the chondrocytes in a monolayer culture is needed, and a homogeneous cell distribution within the gel is guaranteed. Purpose: To report a prospective multicenter study of matrix-associated ACI of the knee using a new type I collagen hydrogel (CaReS). Study Design: Case series; Level of evidence, 4. Methods: From 2003 to 2008, 116 patients (49 women and 67 men; mean age, 32.5 ± 8.9 years) had CaReS implantation of the knee in 9 different centers. On the basis of the International Cartilage Repair Society (ICRS) Cartilage Injury Evaluation Package 2000, the International Knee Documentation Committee (IKDC) score, pain score (visual analog scale [VAS]), SF-36 score, overall treatment satisfaction and the IKDC functional status were evaluated. Patient follow-up was performed at 3, 6, and 12 months after surgery and annually thereafter. Mean follow-up was 30.2 ± 17.4 months (range, 12-60 months). There were 67 defects of the medial condyle, 14 of the lateral, 22 of the patella/trochlea, and 3 of the tibial plateau, and 10 patients had 2 lesions. The mean defect size was 5.4 ± 2.4 cm 2 . Thirty percent of the defects were 〈 4 cm 2 and 70% were 〉 4 cm 2 . Results: The IKDC score improved significantly from 42.4 ± 13.8 preoperatively to 70.5 ± 18.7 ( P 〈 .001) at latest follow-up. Global pain level significantly decreased ( P 〈 .001) from 6.7 ± 2.2 preoperatively to 3.2 ± 3.1 at latest follow-up. There also was a significant increase of both components of the SF-36 score. The overall treatment satisfaction was judged as very good or good in 88% by the surgeon and 80% by the patient. The IKDC functional knee status was grade I in 23.4%, II in 56.3%, III in 17.2%, and IV in 3.1% of the patients. Conclusion: Matrix-associated ACI employing the CaReS technology for the treatment of chondral or osteochondral defects of the knee is a safe and clinically effective treatment that yields significant functional improvement and improvement in pain level. However, further investigation is necessary to determine the long-term viability and clinical outcome of this procedure.
Type of Medium:
Online Resource
ISSN:
0363-5465
,
1552-3365
DOI:
10.1177/0363546511423369
Language:
English
Publisher:
SAGE Publications
Publication Date:
2011
detail.hit.zdb_id:
2063945-4
SSG:
31
Bookmarklink