    Acoustical Society of America (ASA) ; 2009
    In:  The Journal of the Acoustical Society of America Vol. 125, No. 4_Supplement ( 2009-04-01), p. 2740-2740
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 125, No. 4_Supplement ( 2009-04-01), p. 2740-2740
    Abstract: The accurate measurement of pressure waveforms in high intensity focused ultrasound (HIFU) fields is complicated by the fact that many devices operate at output levels where shock waves can form in the focal region. In tissue ablation applications, the accurate measurement of the shock amplitude is important for predicting tissue heating since the absorption at the shock is proportional to the shock amplitude cubed. To accurately measure shocked pressure waveforms, not only must a hydrophone with a broad bandwidth ( & gt;100 MHz) be used, but the frequency response of the hydrophone must be known and used to correct the measured waveform. In this work, shocked pressure waveforms were measured using a fiber optic hydrophone and a frequency response for the hydrophone was determined by comparing measurements with numerical modeling using a KZK-type equation. The impulse response was separately determined by comparing a measured and an idealized shock pulse generated by an electromagnetic lithotripter. The frequency responses determined by the two methods were in good agreement. Calculations of heating using measured HIFU waveforms that had been deconvolved with the determined frequency response agreed well with measurements in tissue phantom. [Work supported by NIH DK43881, NSBRI SMST01601, NIH EB007643, and RFBR.]
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2009
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2006
    In:  The Journal of the Acoustical Society of America Vol. 119, No. 5_Supplement ( 2006-05-01), p. 3228-3228
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 119, No. 5_Supplement ( 2006-05-01), p. 3228-3228
    Abstract: Direct measurement of HIFU fields in situ is important for the accurate prediction of thermal and mechanical bioeffects, as well as for the development of standards for medical systems. An experimentally validated numerical model can be an effective tool in both laboratory and clinical settings when direct measurements are not possible. Calculations with a KZK-type model and measurements with a fiberoptic probe hydrophone were employed together to characterize HIFU fields in water and in a tissue-mimicking gel. To determine the boundary conditions for simulations, the normal velocity distribution on the transducer surface was reconstructed using acoustic holography and combined with acoustic power measurements. At the focus, highly nonlinear waveforms (+700 and −150 bars peak pressures) were obtained both experimentally and numerically, which differed significantly from waveforms linearly extrapolated from low-amplitude results. Strongly distorted shock waveforms were localized in an axial region much smaller than the half-maximum beamwidth of the transducer excited at low level. At the highest excitation levels, the simulations predicted frequency content higher than was measurable in our configuration. Simulations also show that if these frequencies are not included, predicted heating rates are significantly lower. [Work is supported by NIH DK43881, NSBRI SMS00402, and RFBR.]
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2006
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2011
    In:  The Journal of the Acoustical Society of America Vol. 130, No. 5 ( 2011-11-01), p. 3498-3510
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 130, No. 5 ( 2011-11-01), p. 3498-3510
    Abstract: In high intensity focused ultrasound (HIFU) applications, tissue may be thermally necrosed by heating, emulsified by cavitation, or, as was recently discovered, emulsified using repetitive millisecond boiling caused by shock wave heating. Here, this last approach was further investigated. Experiments were performed in transparent gels and ex vivo bovine heart tissue using 1, 2, and 3 MHz focused transducers and different pulsing schemes in which the pressure, duty factor, and pulse duration were varied. A previously developed derating procedure to determine in situ shock amplitudes and the time-to-boil was refined. Treatments were monitored using B-mode ultrasound. Both inertial cavitation and boiling were observed during exposures, but emulsification occurred only when shocks and boiling were present. Emulsified lesions without thermal denaturation were produced with shock amplitudes sufficient to induce boiling in less than 20 ms, duty factors of less than 0.02, and pulse lengths shorter than 30 ms. Higher duty factors or longer pulses produced varying degrees of thermal denaturation combined with mechanical emulsification. Larger lesions were obtained using lower ultrasound frequencies. The results show that shock wave heating and millisecond boiling is an effective and reliable way to emulsify tissue while monitoring the treatment with ultrasound.
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2011
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2008
    In:  The Journal of the Acoustical Society of America Vol. 123, No. 5_Supplement ( 2008-05-01), p. 3003-3003
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 123, No. 5_Supplement ( 2008-05-01), p. 3003-3003
    Abstract: Acoustic characterization of nonlinear HIFU fields is important for both the accurate prediction of ultrasound induced bioeffects and the development of regulatory standards for clinical HIFU devices. In this work a new characterization method is proposed and tested in water, tissue phantoms, and ex-vivo tissues. The method is based on the combined use of measurements and modeling. Experiments were performed with a 2 MHz transducer of 4.2 cm aperture and 4.5 cm focal length. Low amplitude measurements in water were used to establish boundary conditions for modeling based on the KZK-type equation. High amplitude focal waveforms then were simulated and measured with a fiber optic probe hydrophone in water, within tissue phantom, or adjacent to excised tissue. It was shown that at high amplitudes, the simulations of shock waveforms were more accurate than the measurements. The focal waveforms obtained in water were found to be in a good agreement with those produced in tissue with higher source pressure scaled to compensate for the linear attenuation on the way to focus. This result establishes a method to derate the focal HIFU pressures determined in water to tissue. [Work supported by NIH DK43881, NSBRI SMS00402 and RFBR.]
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2008
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2008
    In:  The Journal of the Acoustical Society of America Vol. 124, No. 4 ( 2008-10-01), p. 2406-2420
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 124, No. 4 ( 2008-10-01), p. 2406-2420
    Abstract: Acoustic characterization of high intensity focused ultrasound (HIFU) fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2MHz transducer with an aperture and focal length of 4.4cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24000W∕cm2. The inputs to a Khokhlov–Zabolotskaya–Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80MPa and peak negative pressures up to 15MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000W∕cm2, lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields.
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2008
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2011
    In:  The Journal of the Acoustical Society of America Vol. 129, No. 4_Supplement ( 2011-04-01), p. 2476-2476
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 129, No. 4_Supplement ( 2011-04-01), p. 2476-2476
    Abstract: Recent studies in high intensity focused ultrasound (HIFU) have shown significant interest in generating purely mechanical damage of tissue without thermal coagulation. Here, an approach using millisecond bursts of ultrasound shock waves and repeated localized boiling is presented. In HIFU fields, nonlinear propagation effects lead to formation of shocks only in a small focal region. Significant enhancement of heating due to absorption at the shocks leads to boiling temperatures in tissue in milliseconds as calculated based on weak shock theory. The heated and potentially necrotized region of tissue is small compared to the volume occupied by the mm-sized boiling bubble it creates. If the HIFU pulse is only slightly longer than the time-to-boil, thermal injury is negligible compared to the mechanical injury caused by the exploding boiling bubble and its further interaction with shocks. Experiments performed in transparent gels and various ex vivo and in vivo tissues have confirmed the effectiveness of this emulsification method. In addition, since mm-sized boiling bubbles are highly echogenic, tissue emulsification can be easily monitored in real-time using B-mode ultrasound imaging. [Work supported by NIH EB007643, RFBR 09-02-01530, and NSBRI through NASA NCC 9-58] .
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2011
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2008
    In:  The Journal of the Acoustical Society of America Vol. 123, No. 5_Supplement ( 2008-05-01), p. 3221-3221
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 123, No. 5_Supplement ( 2008-05-01), p. 3221-3221
    Abstract: The characterization of high intensity focused ultrasound (HIFU) fields is important for both clinical treatment planning as well as for regulation of HIFU medical devices. In previous work, we have used a 100-μm fiber optic probe hydrophone (FOPH) to measure pressure waveforms from a 2-MHz HIFU source with 42-mm aperture and 44-mm focal length. The formation of shock waves with peak positive pressure of up to 80-MPa were measured and modeled in transparent tissue-mimicking gel phantoms and boiling was achieved in milliseconds [Canney MS, et al., J. Acoust. Soc. Am., 120:3110 (2006)]. In this work, the FOPH was also used to measure temperature changes in tissue phantoms from HIFU at peak focal intensities of 5000-20,000 W/cm2. Temperature measurements were obtained by first low-pass filtering the voltage signal measured from the FOPH to remove the acoustic part of the measurement. Then, calibration of voltage to temperature was performed using results from a separate calibration experiment. Experimental measurements were compared with numerical modeling using a KZK-type model for acoustic propagation coupled with a heat transfer model. In summary, temperatures of 100°C were measured at the HIFU focus in milliseconds, in agreement with modeling [Work supported by NIH DK43881, NSBRI SMS00402, and RFBR.]
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2008
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2009
    In:  The Journal of the Acoustical Society of America Vol. 125, No. 4_Supplement ( 2009-04-01), p. 2600-2600
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 125, No. 4_Supplement ( 2009-04-01), p. 2600-2600
    Abstract: Shock waves of up to 100 MPa may form at the focus of high-intensity focused ultrasound (HIFU) transducers at clinically reported in situ intensities of up to 30,000 W/cm2. The heating due to shocks is sufficient to boil tissue in milliseconds, which dramatically alters the treatment. Quantification of enhanced heating from shocks is therefore critical to treatment planning. In this work, several approaches and temporal grids of different resolutions were used to simulate HIFU fields. Peak positive pressure, which determines the shock amplitude, and thus the heating rate were found to be the most sensitive to the parameters of the numerical scheme. Heating rates calculated in modeling and estimated using weak shock theory from the measured and modeled waveforms were compared. Time to boil measured in tissue phantoms and tissue was used as a metric of the heating efficiency of shocks. It is shown that the bandwidth limitations in the waveform measurements result in underestimation of the heat rates, although boiling onset predicted in modeling agreed well with the experimental data. An experimentally validated numerical model thus can be an effective tool in both laboratory and clinical HIFU setting. [Work is supported by NIH EB007643 and NSBRI SMST01601.]
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2009
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2009
    In:  The Journal of the Acoustical Society of America Vol. 125, No. 4 ( 2009-04-01), p. 2420-2431
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 125, No. 4 ( 2009-04-01), p. 2420-2431
    Abstract: Both mechanically induced acoustic cavitation and thermally induced boiling can occur during high intensity focused ultrasound (HIFU) medical therapy. The goal was to monitor the temperature as boiling was approached using magnetic resonance imaging (MRI). Tissue phantoms were heated for 20 s in a 4.7-T magnet using a 2-MHz HIFU source with an aperture and radius of curvature of 44 mm. The peak focal pressure was 27.5 MPa with corresponding beam width of 0.5 mm. The temperature measured in a single MRI voxel by water proton resonance frequency shift attained a maximum value of only 73 °C after 7 s of continuous HIFU exposure when boiling started. Boiling was detected by visual observation, by appearance on the MR images, and by a marked change in the HIFU source power. Nonlinear modeling of the acoustic field combined with a heat transfer equation predicted 100 °C after 7 s of exposure. Averaging of the calculated temperature field over the volume of the MRI voxel (0.3×0.5×2 mm3) yielded a maximum of 73 °C that agreed with the MR thermometry measurement. These results have implications for the use of MRI-determined temperature values to guide treatments with clinical HIFU systems.
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2009
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Online Resource
    Online Resource
    Acoustical Society of America (ASA) ; 2010
    In:  The Journal of the Acoustical Society of America Vol. 127, No. 3_Supplement ( 2010-03-01), p. 1760-1760
    In: The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 127, No. 3_Supplement ( 2010-03-01), p. 1760-1760
    Abstract: High-intensity focused ultrasound (HIFU) transducers can be operated at high-pressure amplitudes of greater than 60 MPa and low-duty cycles of 1% or less to induce controlled bubble activity that fractionates tissue. The goal of this work was to investigate fractionation not from mechanically induced cavitation but from thermally induced boiling created by HIFU shock waves. Experiments were performed using a 2-MHz HIFU source. The focus was placed in ex vivo bovine heart and liver samples. Cavitation and boiling were monitored during exposures using a high-voltage probe in parallel with the HIFU source and with an ultrasound imaging system. Various exposure protocols were performed in which the time-averaged intensity and total energy delivered were maintained constant. The types of lesions induced in tissue ranged from purely thermal to purely mechanical depending on the pulsing protocol used. A pulsing protocol in which the pulse length was on the order of the time to boil (of only several milliseconds) and duty cycle was low ( & lt;1%) was found to be a highly repeatable method for inducing mechanical effects with little evidence of thermal damage, as confirmed by histology. [Work supported by NIH EB007643, NSBRI SMST01601, and RFBR 09-02-01530.]
    Type of Medium: Online Resource
    ISSN: 0001-4966 , 1520-8524
    RVK:
    Language: English
    Publisher: Acoustical Society of America (ASA)
    Publication Date: 2010
    detail.hit.zdb_id: 1461063-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages