Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Ovid Technologies (Wolters Kluwer Health)  (3)
  • Garofalo, Eugenio  (3)
Medientyp
Verlag/Herausgeber
  • Ovid Technologies (Wolters Kluwer Health)  (3)
Sprache
Erscheinungszeitraum
Fachgebiete(RVK)
  • 1
    In: Critical Care Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 47, No. 6 ( 2019-06), p. e506-e511
    Kurzfassung: Assessing gas exchange, diaphragm function, respiratory rate, and patient comfort during high-flow oxygen therapy and standard oxygen at the time of noninvasive ventilation discontinuation. Design: Randomized crossover physiologic study. Setting: Two ICUs. Patients: Thirty chronic obstructive pulmonary disease patients with hypercapnic acute respiratory failure receiving noninvasive ventilation greater than 24 hours. Interventions: All patients underwent five 30-minute trials, the first, third, and fifth trial in noninvasive ventilation, whereas the second and fourth were randomly conducted with either standard oxygen and high-flow oxygen therapy. Measurements and Main Results: Diaphragm displacement and thickening fraction were determined by sonographic evaluation at the end of each trial. Arterial blood gases, respiratory rate, and patient comfort were also assessed. Pa co 2 ( p = 0.153) and pH ( p = 0.114) were not different among trials, while Pa o 2 was greater in noninvasive ventilation than with both standard oxygen ( p ≤ 0.005) and high-flow oxygen therapy ( p ≤ 0.001). The diaphragm displacement was no different among trials ( p = 0.875), while its thickening fraction was greater with standard oxygen, compared with high-flow oxygen therapy and all noninvasive ventilation trials ( p 〈 0.001 for all comparisons), without differences between high-flow oxygen therapy and noninvasive ventilation. Respiratory rate also increased with standard oxygen, compared with both high-flow oxygen therapy ( p 〈 0.001) and noninvasive ventilation ( p 〈 0.01). High-flow oxygen therapy improved comfort, compared with standard oxygen ( p = 0.004) and noninvasive ventilation ( p 〈 0.001). Conclusions: At the time of noninvasive ventilation interruption, Pa co 2 and diaphragm displacement remained unchanged regardless of the modality of oxygen administration. However, although standard oxygen resulted in a remarkable increase in diaphragm thickening fraction, high-flow oxygen therapy allowed maintaining it unchanged, while improving patient comfort.
    Materialart: Online-Ressource
    ISSN: 0090-3493
    Sprache: Englisch
    Verlag: Ovid Technologies (Wolters Kluwer Health)
    Publikationsdatum: 2019
    ZDB Id: 2034247-0
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    In: Anesthesiology, Ovid Technologies (Wolters Kluwer Health), Vol. 137, No. 3 ( 2022-09-01), p. 341-350
    Kurzfassung: Retracted articles represent research withdrawn from the existing body of literature after publication. Research articles may be retracted for several reasons ranging from honest errors to intentional misconduct. They should not be used as reliable sources, and it is unclear why they are cited occasionally by other articles. This study hypothesized that several mechanisms may contribute to citing retracted literature and aimed to analyze the characteristics of articles citing retracted literature in anesthesiology and critical care. Methods Using the Retraction Watch database, we retrieved retracted articles on anesthesiology and intensive care medicine up to August 16, 2021, and identified the papers citing these retracted articles. A survey designed to investigate the reasons for citing these articles was sent to the corresponding authors of the citing papers. Results We identified 478 retracted articles, 220 (46%) of which were cited at least once. We contacted 1297 corresponding authors of the papers that cited these articles, 417 (30%) of whom responded to our survey and were included in the final analysis. The median number of authors in the analyzed articles was five, and the median elapsed time from retraction to citation was 3 yr. Most of the corresponding authors (372, 89%) were unaware of the retracted status of the cited article, mainly because of inadequate notification of the retraction status in journals and/or databases and the use of stored copies. Conclusions The corresponding authors were generally unaware of the retraction of the cited article, usually because of inadequate identification of the retracted status in journals and/or web databases and the use of stored copies. Awareness of this phenomenon and rigorous control of the cited references before submitting a paper are of fundamental importance in research. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
    Materialart: Online-Ressource
    ISSN: 0003-3022 , 1528-1175
    RVK:
    Sprache: Englisch
    Verlag: Ovid Technologies (Wolters Kluwer Health)
    Publikationsdatum: 2022
    ZDB Id: 2016092-6
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    In: Anesthesia & Analgesia, Ovid Technologies (Wolters Kluwer Health), Vol. 127, No. 6 ( 2018-12), p. 1353-1364
    Kurzfassung: Assessing the volemic status of patients undergoing surgery is part of the routine management for the anesthesiologist. This assessment is commonly performed by means of dynamic indexes based on the cardiopulmonary interaction during mechanical ventilation (if available) or by administering a fluid challenge (FC). The FC is used during surgery to optimize predefined hemodynamic targets, the so-called Goal-Directed Therapy (GDT), or to correct hemodynamic instability (non-GDT). METHODS: In this systematic review, we considered the FC components in studies adopting either GDT or non-GDT, to assess whether differences exist between the 2 approaches. In addition, we performed a meta-analysis to ascertain the effectiveness of dynamic indexes pulse pressure variation (PPV) and stroke volume (SV) variation (SVV), in predicting fluid responsiveness. RESULTS: Thirty-five non-GDT and 33 GDT studies met inclusion criteria, including 5017 patients. In the vast majority of non-GDT and GDT studies, the FC consisted in the administration of colloids (85.7% and 90.9%, respectively). In 29 non-GDT studies, the colloid infused was the 6% hydroxyethyl starch (6% HES; 96.6% of this subgroup). In 20 GDT studies, the colloid infused was the 6% HES (66.7% of this subgroup), while in 5 studies was a gelatin (16.7% of this subgroup), in 3 studies an unspecified colloid (10.0% of this subgroup), and in 1 study albumin (3.3%) or, in another study, both HES 6% and gelatin (3.3%). In non-GDT studies, the median volume infused was 500 mL; the time of infusion and hemodynamic target to assess fluid responsiveness lacked standardization. In GDT studies, FC usually consisted in the administration of 250 mL of colloids (48.8%) in 10 minutes (45.4%) targeting an SV increase 〉 10% (57.5%). Only in 60.6% of GDT studies, a safety limit was adopted. PPV pooled area under the curve (95% confidence interval [CI]) was 0.86 (0.80–0.92). The mean (standard deviation) PPV threshold predicting fluid responsiveness was 10.5% (3.2) (range, 8%–15%), while the pooled (95% CI) sensitivity and specificity were 0.80 (0.74–0.85) and 0.83 (0.73–0.91), respectively. SVV pooled area under the curve (95% CI) was 0.87 (0.81–0.93). The mean (standard deviation) SVV threshold predicting fluid responsiveness was 11.3% (3.1) (range, 7.5%–15.5%), while the pooled (95% CI) sensitivity and specificity were 0.82 (0.75–0.89) and 0.77 (0.71–0.82), respectively. CONCLUSIONS: The key components of FC including type of fluid (colloids, often 6% HES), volume (500 and 250 mL in non-GDT studies and GDT studies, respectively), and time of infusion (10 minutes) are quite standardized in operating room. However, pooled sensitivity and specificity of both PPV and SVV are limited.
    Materialart: Online-Ressource
    ISSN: 0003-2999
    RVK:
    Sprache: Englisch
    Verlag: Ovid Technologies (Wolters Kluwer Health)
    Publikationsdatum: 2018
    ZDB Id: 2018275-2
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz