In:
e-Journal of Nondestructive Testing, NDT.net GmbH & Co. KG, Vol. 27, No. 3 ( 2022-03)
Abstract:
In this work, we apply and adapt established Probability of Detection (POD) methods on inline inspection of aluminium cylinder heads using X-ray computed tomography. The CT simulation tool SimCT [4] is used to acquire virtual images of the specimens including artificial defects, which avoids the manufacturing of calibrated defects of known type (e.g., pore, inclusion, crack etc.), size and location. One of the exemplary defects is discussed as representative result together with the generated POD curves as well as its characteristics (i.e., the minimum detected defect, the maximum missed defect, POD(a90) =0.90 and a90/95).
Type of Medium:
Online Resource
ISSN:
1435-4934
Language:
Unknown
Publisher:
NDT.net GmbH & Co. KG
Publication Date:
2022
detail.hit.zdb_id:
2021293-8
Bookmarklink