Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Travers, Paul J.  (1)
Type of Medium
Language
Years
Subjects(RVK)
  • 1
    Online Resource
    Online Resource
    American Society for Microbiology ; 2004
    In:  Journal of Clinical Microbiology Vol. 42, No. 11 ( 2004-11), p. 5170-5175
    In: Journal of Clinical Microbiology, American Society for Microbiology, Vol. 42, No. 11 ( 2004-11), p. 5170-5175
    Abstract: A “gold standard” method for the diagnosis of bacterial vaginosis (BV) is lacking. The clinical criteria described by the Amsel technique are subjective and difficult to quantify. Alternatively, the reading of Gram-stained vaginal smears by scoring techniques such as those that use the Nugent or Hay-Ison scoring systems is again subjective, requires expert personnel to perform the reading, and is infrequently used clinically. Recently, a new diagnostic device, the Osmetech Microbial Analyzer—Bacterial Vaginosis (OMA-BV), which determines a patient's BV status on the basis of measurement of the amount of acetic acid present in a vaginal swab specimen, was approved by the Food and Drug Administration. The present study uses the conducting polymer gas-sensing technology of OMA-BV to measure the concentration of acetic acid in the headspace above vaginal swab specimens from patients undergoing treatment for BV with metronidazole. In 97.8% of the cases the level of acetic acid detected fell sharply during the treatment period, crossing from above to below the diagnostic threshold of 900 ppm. The diagnosis obtained on the basis of the level of vaginal acetic acid was compared with the diagnoses obtained by use of the Amsel criteria and the Nugent scoring system both at the time of initial entry into the study and at the repeat samplings on days 7 and 14. The results obtained with OMA-BV showed overall agreements compared with the results of the Amsel and Nugent tests of 98 and 94%, respectively, for the 34 patients monitored through the treatment process. This provides further evidence that the measurement of vaginal acetic acid by headspace analysis with conducting polymer sensors is a valid alternative to present tests for the diagnosis of BV.
    Type of Medium: Online Resource
    ISSN: 0095-1137 , 1098-660X
    RVK:
    Language: English
    Publisher: American Society for Microbiology
    Publication Date: 2004
    detail.hit.zdb_id: 1498353-9
    SSG: 12
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages