Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Wu, Lixin  (5)
Type of Medium
Publisher
Language
Years
  • 1
    In: Energies, MDPI AG, Vol. 13, No. 6 ( 2020-03-13), p. 1347-
    Abstract: The analysis and calculation of the short-circuit fault current in the DC grid is of great significance to the design and configuration of the converter station and DC circuit breaker parameters. The existing flexible DC system not only includes the modular multilevel converter (MMC) converter, but also needs power equipment such as the fault current limiter and DC circuit breaker. Therefore, the system modeling and short circuit calculation of the multi-terminal DC system after adding the DC circuit breaker are also of great significance for the design of DC power system parameters and the grid troubleshooting ability. In this paper, firstly, the parameters of the four-terminal DC system of the modular multilevel converter (MMC) are simplified, and the analytical solution of the short circuit fault current of the multi-terminal DC system is given. Then, the external characteristics of the cascaded hybrid DC circuit breaker are modeled. Based on the equivalent circuit of the fault current in different stages, the short circuit calculation method of four-terminal MMC system with DC circuit breaker is obtained. This method can effectively describe the overall trend of fault current and provide the basis for the configuration of DC line protection settings and DC circuit breaker related parameters.
    Type of Medium: Online Resource
    ISSN: 1996-1073
    Language: English
    Publisher: MDPI AG
    Publication Date: 2020
    detail.hit.zdb_id: 2437446-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    IOP Publishing ; 2020
    In:  IOP Conference Series: Earth and Environmental Science Vol. 508, No. 1 ( 2020-05-01), p. 012039-
    In: IOP Conference Series: Earth and Environmental Science, IOP Publishing, Vol. 508, No. 1 ( 2020-05-01), p. 012039-
    Abstract: DC line fault is one of the important factors restricting the development of flexible DC system. DC circuit breaker is an effective means to realize the short circuit fault isolation on DC side of flexible DC system. Therefore, it is necessary to add DCCB into the short-circuit current calculation and modeling of MMC-HVDC power grid for comprehensive analysis. Firstly, the external characteristics of the hybrid HVDC circuit breaker and the modular multilevel converter (MMC) are modelled. Then, the modeling of short-circuit fault current in different stages was analysed. The analysis method of short circuit fault current of four-terminal MMC system with DC circuit breaker is obtained. Finally, the simulation results and the calculation results are compared and results show the effectiveness of the short-circuit calculation method proposed by this paper.
    Type of Medium: Online Resource
    ISSN: 1755-1307 , 1755-1315
    Language: Unknown
    Publisher: IOP Publishing
    Publication Date: 2020
    detail.hit.zdb_id: 2434538-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    MDPI AG ; 2022
    In:  Energies Vol. 15, No. 17 ( 2022-08-25), p. 6189-
    In: Energies, MDPI AG, Vol. 15, No. 17 ( 2022-08-25), p. 6189-
    Abstract: Voltage stability has always been a hot topic in power system research. Traditional On-Load Tap-Charger (OLTC) transformer is considered to play a very important role in the system voltage stability. However, in the heavy load of distribution network, the tap adjustment of OLTC transformer will lead to the shift of critical stable operating point, which bring the “negative voltage regulating effect” of voltage adjustment, and even cause the instability of system voltage. This paper presents a Flexible On-Load Voltage Regulation (OLVR) transformer based on power electronic technology. The Flexible On-Load Voltage Regulation (OLVR) transformer is a combination of Power Electronic Converter (PEC) and OLTC transformer, which can realize voltage step-less regulation and reactive power regulation. Meanwhile, the paper presents the equivalent models of distribution network with Flexible OLVR transformer and analyzes the critical operating point. Through the step-less voltage regulation control of the Flexible OLVR transformer, the negative voltage regulation effect of the transformer in on-load voltage regulation is avoided, and the voltage stability of the distribution network is improved.
    Type of Medium: Online Resource
    ISSN: 1996-1073
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2437446-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Elsevier BV ; 2022
    In:  Electric Power Systems Research Vol. 209 ( 2022-08), p. 107946-
    In: Electric Power Systems Research, Elsevier BV, Vol. 209 ( 2022-08), p. 107946-
    Type of Medium: Online Resource
    ISSN: 0378-7796
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2022
    detail.hit.zdb_id: 1502242-0
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    MDPI AG ; 2022
    In:  Energies Vol. 15, No. 17 ( 2022-08-25), p. 6193-
    In: Energies, MDPI AG, Vol. 15, No. 17 ( 2022-08-25), p. 6193-
    Abstract: The application of on-load tap-charger (OLTC) transformer technology has become the most direct and effective way to solve the voltage fluctuation of power grid. With the development of active distribution technology, the research focus of on-load voltage regulation technology has gradually turned to the development direction of arc free, fast and intelligent. This paper presents a flexible on-load voltage regulation topology based on power electronic technology. The flexible on-load voltage regulation (flexible OLVR) transformer is a combination of power electronic technology and traditional on-load tap-charger transformer, which can realize fast arcless switching, voltage step-less regulation, power regulation and other functions. In this paper, a new type of flexible on-load voltage regulation transformer is proposed. The OLTC switches of the device adopts the power electronic switch of anti-parallel thyristors, which can realize step, fast and arcless voltage regulation; the power electronic converter (PEC) module is connected to the primary side of the main transformer. At the same time, it proposed a new reactive power compensation control strategy, which could realize the functions of step-less voltage regulation and reactive power compensation. In the end, the rationality and validity of the proposed topology is tested and verified by simulations and experimental tests.
    Type of Medium: Online Resource
    ISSN: 1996-1073
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2437446-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages