Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences  (51)
Medientyp
Verlag/Herausgeber
  • Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences  (51)
Sprache
Erscheinungszeitraum
  • 1
    Online-Ressource
    Online-Ressource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2021
    In:  Acta Physica Sinica Vol. 70, No. 8 ( 2021), p. 082901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 8 ( 2021), p. 082901-
    Kurzfassung: At present, there exist few proton-beam terminals for the detector calibration in the world. Meanwhile, most of these terminals provide monoenergetic protons. Back-n white neutron source from China Spallation Neutron Source(CSNS) was put into operation in 2018. Based on the white neutron flux ranging from 0.5 eV to 200 MeV from the CSNS Back-n white neutron source, continuous-energy protons involved in a wide energy spectrum can be acquired from the 〈sup〉1〈/sup〉H(n, el) reaction. Adopting this method, a new research platform for researches such as proton calibration is realized at CSNS. As hydrogen exists as gas at normal temperature and pressure, in the selecting of the proton-converting target, the hydrogen-rich compounds are preferential considered. Considering the reaction cross sections of the 〈sup〉1〈/sup〉H(n, el), 〈sup〉12〈/sup〉C(n, p)〈sup〉12〈/sup〉B, 〈sup〉12〈/sup〉C(n, d)〈sup〉11〈/sup〉B, 〈sup〉12〈/sup〉C(n, t)〈sup〉10〈/sup〉B, 〈sup〉12〈/sup〉C(n, 〈sup〉3〈/sup〉He)〈sup〉10〈/sup〉Be, 〈sup〉12〈/sup〉C(n, α)〈sup〉9〈/sup〉Be and 〈sup〉1〈/sup〉H(n, γ)〈sup〉2〈/sup〉H, polyethylene and polypropylene are suitable for serving as targets in this research. Based on a 3U PXIe, digitizers with 1 GSps sampling rate and 12 bit resolution are utilized to digitize and record the output signals of telescopes. The time and amplitude information of each signal are extracted from its recorded waveform. Proton fluxes can be calculated by using the neutron energy spectrum and the cross section of the 〈sup〉1〈/sup〉H(n, el) reaction. Using the γ-flash event as the starting time of the time-of-flight (TOF) and the time information of signal in detector as the stopping time, the kinematic energy of each secondary proton can be deduced from the TOF and the angle of the detector. A calibration experiment on three charged particle telescopes, with each telescope consisting of a silicon detector and a CsI(Tl) detector, is carried out on this research platform. The readout methods of the CsI(Tl) detectors in these three telescopes are different. In the calibration experiment, Δ〈i〉E-〈/i〉〈i〉E〈/i〉 two-dimensional spectra and amplitude-〈i〉E〈/i〉〈sub〉p〈/sub〉 two-dimensional spectra of these telescopes are obtained. Through comparing these particle identification spectra, the SiPM is chosen as the signal readout method for CsI(Tl) detectors in the charged particle telescopes. These researches provide experimental evidence for the construction of the charged particle telescope at Back-n, and also illustrate the feasibility of wide-energy spectrum proton calibration based on the Back-n white neutron source.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2021
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Online-Ressource
    Online-Ressource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2021
    In:  Acta Physica Sinica Vol. 70, No. 22 ( 2021), p. 222801-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 22 ( 2021), p. 222801-
    Kurzfassung: The data of neutron capture cross section are very important for the research of nuclear astrophysics, advanced nuclear energy development. Owing to the limitation of neutron source and detector, the experimental data of neutron capture cross section in an energy range of 1 eV–10 keV were almost blank in China. The first Chinese gamma-ray total absorption facility has been constructed in the key laboratory of nuclear data at China institute of atomic energy, which consists of 40 BaF〈sub〉2〈/sub〉 detector units. The BaF〈sub〉2〈/sub〉 crystal shell with a thickness of 15 cm and an inner radius of 10 cm covers 95.2% of the solid angle. On-line measurement method of neutron capture reaction cross section is established on the back-streaming white neutron source of China spallation neutron source by using the upgraded facility. The cross section of 〈sup〉197〈/sup〉Au neutron capture reaction is measured for the first time under the experimental condition of irregular 30 mm neutron beam spot. The measured position of resonance peak is well consistent with the relevant data of ENDF evaluation database, which verifies the reliability of the measurement device and measurement technology, and thus laying the foundation for the acquisition of high precision cross section in future.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2021
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Online-Ressource
    Online-Ressource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2024
    In:  Acta Physica Sinica Vol. 73, No. 7 ( 2024), p. 072801-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 73, No. 7 ( 2024), p. 072801-
    Kurzfassung: Neutron capture reaction is one of the neutron reactions and plays an important role in using reactor control rods and shell materials, designing nuclear device structures, and studying nuclear astrophysics S processes and element origins. The 4π BaF 〈 sub 〉 2 〈 /sub 〉 detection device has advantages such as high time resolution, low neutron sensitivity, and high detection efficiency, thus making it suitable for measuring neutron radiation capture reaction cross-section data. In order to fill the gap in our neutron capture reaction data in the keV energy range and improve their accuracy, the Key Laboratory of Nuclear Data at the Chinese Institute of Atomic Energy (CIAE) has established a Gamma Total Absorption Facility (GTAF), which consists of 28 hexagonal BaF 〈 sub 〉 2 〈 /sub 〉 crystals and 12 pentagonal BaF 〈 sub 〉 2 〈 /sub 〉 crystals to form a spherical shell with an external diameter of 25 cm and an internal diameter of 10 cm, covering 95.2% of the solid angles. The Back-n beam line of the Chinese Spallation Neutron Source (CSNS) is a back-streaming white beam line that covers neutron energy ranging from a few eV to several hundred MeV, making it suitable for measuring neutron capture cross-sections. The reaction cross-section data of 〈 sup 〉 197 〈 /sup 〉 Au is measured by using GTAF on the Back-n beam line. The measurement data are preliminarily background deducted through energy screening, PSD method, and crystal multiplicity screening. Subsequently, the background is analyzed and deducted based on the measurement data of 〈 sup 〉 nat 〈 /sup 〉 C and empty samples, and the yield of 〈 sup 〉 197 〈 /sup 〉 Au capture reaction is obtained. Resonance parameters are a set of parameters extracted from experimental data to describe the resonance curve, which can eliminate the influence of experimental conditions on resonance data and are more important than the cross-section obtained from experiments. The resonance energy, neutron resonance width, and gamma resonance width parameters of 〈 sup 〉 197 〈 /sup 〉 Au at 1–100 eV are fitted by using the SAMMY program. From the comparison between the resonance curves obtained from experimental measurements and the resonance parameters obtained from fitting with the ENDF/B-VIII.0 database, it can follow that the experimental measurement results are in good agreement with the database, nevertheless, there exist some differences in the resonance parameter, which may be due to the GTAF energy resolution, Back-n neutron spectrum measurement accuracy, and the experimental background deduction method. Our next work is to identify the sources of difference.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2024
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Online-Ressource
    Online-Ressource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2020
    In:  Acta Physica Sinica Vol. 69, No. 17 ( 2020), p. 172901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 69, No. 17 ( 2020), p. 172901-
    Kurzfassung: The back-streaming neutron beam line (Back-n) was built in the beginning of 2018, which is part of the China Spallation Neutron Source (CSNS). The Back-n is the first white neutron beam line in China, and its main application is for nuclear data measurement. For most of neutron-induced nuclear reaction measurements based on white neutron facilities, the beam of gamma rays accompanied with neutron beam is one of the most important experimental backgrounds. The back streaming neutron beam is transported directly from the spallation target to the experimental station without any moderator or shielding, the flux of the in-beam gamma rays in the experimental station is much larger than those of these facilities with neutron moderator and shielding. Therefore, it is necessary to consider the influence of in-beam gamma rays on the experimental results. Studies of the in-beam gamma rays are carried out at the back-n. Monte-Carlo simulation is employed to obtain the energy distribution and the time structure of the in-beam gamma rays. According to the simulation results, when the neutron flight time is longer than 1.0 μs the energy distribution of the in-beam gamma rays does not vary with flight time. Therefore, the time structure of these gamma rays can be measured without the correction of the detection efficiency. In this work, the time structure of the in-beam gamma rays in the low neutron energy region is measured by both direct and indirect methods. In the direct measurement, a 〈sup〉6〈/sup〉Li loaded ZnS(Ag) scintillator is located on the neutron beam line and the time of flight method is used to determine the time structure of neutrons and gamma rays. The gamma rays are separated from neutrons with pulse-shape discrimination. The black filter method is used to verify the particle discrimination results. In the indirect measurement, the C〈sub〉6〈/sub〉D〈sub〉6〈/sub〉 scintillation detectors are used to measure the gamma rays scattered off a Pb sample on the way of the neutron beam. The time structure of the in-beam gamma rays is derived from that of the scattered gamma rays. The experimental results are in good agreement with the simulations with the time-of-flight between 12 μs and 2.0 ms. Besides, according to the simulation results, the intensity of the in-beam gamma rays is 1.21 × 10〈sup〉6〈/sup〉 s〈sup〉–1〈/sup〉·cm〈sup〉–2〈/sup〉 in the center of the experimental station 2 of Back-n, which is 76.5 m away from the spallation target of CSNS.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2020
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Online-Ressource
    Online-Ressource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2019
    In:  Acta Physica Sinica Vol. 68, No. 10 ( 2019), p. 109901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 68, No. 10 ( 2019), p. 109901-
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2019
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Online-Ressource
    Online-Ressource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2019
    In:  Acta Physica Sinica Vol. 68, No. 8 ( 2019), p. 080101-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 68, No. 8 ( 2019), p. 080101-
    Kurzfassung: The Chinese spallation neutron source was completed in May 2018 and then subsequently commissioned. The Back-streaming white neutron beam line can be used in neutron nuclear data measurement, neutron physics research, and nuclear technology. In these experiments, it is necessary to know the neutron energy spectrum, the neutron flux, and the neutron beam profile of the neutron beam. In this paper, we present the preliminary measurements of these parameters. The neutron energy spectrum and neutron flux are measured by the time-of-flight method with a fission chamber equipped with 〈sup〉235〈/sup〉U and 〈sup〉238〈/sup〉U samples and a 〈sup〉6〈/sup〉Li-Si detector. The neutron beam profile is measured by a scintillator-CMOS detection system. The preliminary experimental measurements of the beam line are obtained. Among them, the energy spectrum measurement range of white neutrons is from eV to more than 100 MeV, which also gives an uncertainty analysis; the neutron fluence rate gives the full power value of the two experimental halls; the collimated white neutron beam spot is given under a diameter of 60 mm. The future plan is also given. The results of these experimental parameters can serve as the foundation for the future nuclear data measurement and detector calibration experiments of the beam line.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2019
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 66, No. 3 ( 2017), p. 039401-
    Kurzfassung: Plasmaspheric hiss plays an important role in driving the precipitation loss of radiation belt electrons via pitch angle scattering, which is also known as the major cause of the formation of the slot region between the inner and outer radiation belt. Therefore, it is of scientific importance to acquire a complete picture of the global distribution of plasmaspheric hiss. Using the thirty-three month high-quality wave data of the Van Allen Probes from September 2012 to May 2015, which provide excellent coverage in the entire inner magnetosphere, we investigate in detail the characteristics of the global distribution of plasmaspheric hiss bin-averaged wave amplitude and occurrence rate with respect to the geomagnetic activity level, L-shell, geomagnetic latitude, and magnetic local time. It is demonstrated that the bin-averaged hiss amplitude strongly depends on the level of geomagnetic activity and exhibits a pronounced day-night asymmetry. Dayside hiss shows a tendency intensifying with the disturbed geomagnetic condition, which is primarily confined to L=2.5-4.0. In contrast, the average hiss amplitude on the nightside tends to decrease. It should also be noted that plasmaspheric hiss at different amplitude levels varies distinctly with geomagnetic condition. As the geomagnetic disturbance increases, the occurrence rate of hiss wave at a smaller amplitude level (i.e., 5-30 pT) increases on the nightside but decreases on the dayside, while the occurrence pattern of higher amplitude ( 30 pT) hiss wave is opposite. For high amplitude hiss wave, the occurrence rate increases on the dayside during intense geomagnetic activities while decreases on the nightside. This is probably because during active times, suprathermal electron fluxes are larger on the nightside, which causes stronger Landau damping of whistler mode waves and thus limits the ability of chorus waves to propagate into the plasmasphere and evolve into plasmaspheric hiss. In addition, plasmaspheric hiss waves with the amplitudes ranging from 5 to 30 pT have the highest occurrence probability both around the geomagnetic equator and at higher latitudes. Our statistical results can provide a reasonable and accurate cognition complementary to the current knowledge of the global features of plasmaspheric hiss, especially in the inner magnetosphere of L=2-6, thereby offering essential input parameters of hiss wave distribution for future simulations of the dynamic spatiotemporal variations of radiation belt electrons at different energies and pitch angles under the influence of diverse solar wind and magentospheric circumstances. Therefore, we suggest that these new properties of hiss wave should be incorporated into the future modeling of radiation belt electron dynamics.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2017
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 63, No. 14 ( 2014), p. 147802-
    Kurzfassung: In this paper, Raman modes of bi-layer graphene are investigated in detail in the frequency region between 1800 and 2150 cm-1. There are four dominant Raman modes in this frequency region. The frequencies of these modes dependent on excitation energy are revealed from the measurement with multi-wavelength lasers, which can be fully understood based on double resonance Raman scattering and the phonon dispersion relation of monolayer graphene. The results show that these Raman modes can be assigned to the combinational modes from the fundamental modes of iTA, LA and LO phonons, but not from iTO and oTO phonons as reported in the previous works. This study benefits us toward the full understanding of lattice dynamics of monolayer and multilayer graphenes.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2014
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Online-Ressource
    Online-Ressource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2008
    In:  Acta Physica Sinica Vol. 57, No. 9 ( 2008), p. 5838-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 57, No. 9 ( 2008), p. 5838-
    Kurzfassung: The density functional theory and full-potential linearized augmented plane wave (FLAPW) method are used to study the anisotropic optical properties of superconductor MgB2. The optical conductivity spectra,the reflectivity spectra and electron energy loss spectra have been calculated. The calculated optical conductivity spectra along xx-axis display quite different features in comparison with that along the zz-axis,while the reflectivity spectra coincide well with the corresponding electron energy loss spectra,especially with respect to the characteristic peaks. In the optical conductivity spectra,the first intra-band absorption peak along xx-axis appears at 20000cm-1 while along zz-axis it appears at a high frequency of about 40000cm-1. In order to simulate the temperature effect in these spectra,the Lorentz expansion (δ=0.10eV) is added to the optical matrix elements in the calculation for 0K. In comparison with existing experimental data,a minor discrepancy of 1000cm-1 (~0.124eV) has been found in the calculated optical spectra.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2008
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Online-Ressource
    Online-Ressource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2004
    In:  Acta Physica Sinica Vol. 53, No. 1 ( 2004), p. 137-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 53, No. 1 ( 2004), p. 137-
    Kurzfassung: In this paper, principles for monocyclic pulse generation by crossed phase modulation in silicon fibers are introduced. The effect of pulse parameters on the spectra broadening is analyzed in detail. For an actual example, split-step Fourier method is performed to verify the theoretic analytic results. Finally, an ultrabroad-band spectrum ranging from 200 to 1000THz and its ideally compressed pulse is achieved.
    Materialart: Online-Ressource
    ISSN: 1000-3290 , 1000-3290
    Sprache: Unbekannt
    Verlag: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publikationsdatum: 2004
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz