Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Wiley ; 2018
    In:  Journal of Field Robotics Vol. 35, No. 2 ( 2018-03), p. 202-212
    In: Journal of Field Robotics, Wiley, Vol. 35, No. 2 ( 2018-03), p. 202-212
    Abstract: Information on which weed species are present within agricultural fields is a prerequisite when using robots for site‐specific weed management. This study proposes a method of improving robustness in shape‐based classifying of seedlings toward natural shape variations within each plant species. To do so, leaves are separated from plants and classified individually together with the classification of the whole plant. The classification is based on common, rotation‐invariant features. Based on previous classifications of leaves and plants, confidence in correct assignment is created for the plants and leaves, and this confidence is used to determine the species of the plant. By using this approach, the classification accuracy of eight plants species at early growth stages is increased from 93.9% to 96.3%.
    Type of Medium: Online Resource
    ISSN: 1556-4959 , 1556-4967
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2018
    detail.hit.zdb_id: 2224269-7
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: The Photogrammetric Record, Wiley, Vol. 37, No. 178 ( 2022-06), p. 228-247
    Abstract: 同一场景的影像之间的亮度差异问题对无人驾驶飞行器(UAV)摄影测量领域很重要,并影响到最终产品的美观和解释。这个问题可能是由相机或太阳的位置变化以及天气条件造成的。本文讨论的是由后者引起的影像亮度变化问题。对获取的RGB影像进行相对辐射归一化(RRN)用以减少这种现象的影响,并提高最终产品的视觉质量。所提出的算法考虑了无人机获取数据的特殊性。它利用影像的位置和它们的关系来分组类似的影像,选择参考,并通过直方图匹配来执行RRN。最终的方法是稳健的和全自动的。在两个独立的数据集上进行的验证证实了它在质量上(改善正射影像的外观)和数量上的有效性。
    Type of Medium: Online Resource
    ISSN: 0031-868X , 1477-9730
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2022
    detail.hit.zdb_id: 2104419-3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Wiley ; 2023
    In:  Scandinavian Journal of Caring Sciences Vol. 37, No. 2 ( 2023-06), p. 534-548
    In: Scandinavian Journal of Caring Sciences, Wiley, Vol. 37, No. 2 ( 2023-06), p. 534-548
    Abstract: QUALIDEM is a dementia‐specific QoL instrument that allows a proxy‐based Quality of Life rating in all stages of dementia. It was originally developed in The Netherlands and has later been translated into English and German. This study endeavoured to translate, cross‐culturally adapt and test important psychometric properties of a Danish version in a cross‐sectional validation study with a nested test–retest design. Method All items underwent forward and backward translation by bilingual academics. Persons with dementia were recruited from 28 healthcare units in a Danish municipality. The severity of dementia was determined using a pragmatic approach allowing the site team to trichotomise the disease (mild, moderate–severe and very severe) before scoring the QUALIDEM. Psychometric properties for QUALIDEM were determined for item characteristics, construct validity, internal consistency, test–retest reliability, measurement error and floor and ceiling effects. The study was approved by The Danish Data Protection Agency. Results A total of 169 persons with dementia, aged 51–103, were included. The construct validity testing showed that the overall proportion of correctly hypothesised correlations was 83%. Testing for internal consistency, Cronbach's α ranged from 0.65 to 0.85 in mild–severe dementia with three out of nine subscales having values below 0.7. For very severe dementia, Cronbach's α ranged from 0.44 to 0.81, with three out of six subscales having insufficient values. For test–retest reliability, the intra‐class correlation coefficients ranged from 0.56 to 0.86. The ‘scale width’ method revealed a marked ceiling effect in all subscales ranging from 30.6% to 87.7%. Discussion The QUALIDEM was successfully translated and cross‐culturally adapted into Danish. Most subscales show acceptable internal consistency and test–retest reliability. However, a substantial measurement error and ceiling effect was present in most subscales. Conclusion With few exceptions, the subscales of the Danish version of QUALIDEM have acceptable validity and reliability. Future research should address the limitations of the ceiling effects.
    Type of Medium: Online Resource
    ISSN: 0283-9318 , 1471-6712
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2023
    detail.hit.zdb_id: 2031090-0
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages