In:
Journal of Ultrasound in Medicine, Wiley, Vol. 36, No. 3 ( 2017-03), p. 571-581
Abstract:
To determine the intrarater reliability and precision of lumbar multifidus and transversus abdominis thickness measurements using freehand sonography in a range of static and dynamic conditions. Methods Fifteen asymptomatic participants performed a range of exercises while sonography was used to measure absolute muscle thickness and changes in muscle thickness from rest. Exercise conditions included the abdominal drawing‐in maneuver, active straight leg raise, contralateral arm lift, both unloaded and loaded, treadmill walking, and using the Functional Readaptive Exercise Device. Intraday and interday reliability was assessed by intraclass correlation coefficients, and the standard error of measurement was used to assess measurement precision. Results Good to excellent reliability was achieved for absolute transversus abdominis and lumbar multifidus thickness in all conditions. Measurement precision for absolute lumbar multifidus thickness was ≤2.8 mm for the unloaded contralateral arm lift, ≤1.8 mm for the loaded contralateral arm lift, ≤3.1 mm for treadmill walking, and ≤3.8 mm for the Functional Readaptive Exercise Device; for absolute transversus abdominis thickness, precision was ≤0.6 mm for the abdominal drawing‐in maneuver, ≤0.5 mm for the active straight leg raise, ≤0.7 mm for treadmill walking, and ≤0.5 mm for the Functional Readaptive Exercise Device. Good to excellent reliability was achieved for relative transversus abdominis and lumbar multifidus thickness in all conditions. Measurement precision for relative lumbar multifidus thickness was ≤3.7% for the unloaded contralateral arm lift, ≤3.8% for the loaded contralateral arm lift, ≤6.3% for treadmill walking, and ≤7.6% for the Functional Readaptive Exercise Device; for relative transversus abdominis thickness, precision was ≤13.6% for the abdominal drawing‐in maneuver, ≤6.9% for the active straight leg raise, ≤11.1% for treadmill walking, and ≤7.2% for the Functional Readaptive Exercise Device. Conclusions Acceptable reliability and precision of measurement is achieved for absolute and relative measures of deep spinal muscle thickness using freehand sonography in relatively static and dynamic exercises.
Type of Medium:
Online Resource
ISSN:
0278-4297
,
1550-9613
DOI:
10.7863/ultra.16.03059
Language:
English
Publisher:
Wiley
Publication Date:
2017
detail.hit.zdb_id:
604829-8
detail.hit.zdb_id:
2067124-6
Bookmarklink