Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: BMC Gastroenterology, Springer Science and Business Media LLC, Vol. 20, No. 1 ( 2020-12)
    Abstract: A new capsule endoscopy (CE) system featuring two advanced optics for 344°-viewing and a prolonged operative time has been recently developed for Crohn’s disease (CD) patients. Hence, we evaluated, for the first time, the performance of this novel CE and the add-on value of the 344°-viewing in a multi-center real-life setting. Methods Consecutive patients with suspected or established CD received the PillCam™ Crohn’s System as supplementary diagnostic work-up focused on the small-bowel between June 2017 and June 2018. Technical and clinical data, including the panenteric CE diagnostic yield, the Lewis score and the impact of small-bowel findings on clinical management during a 6-months follow-up (new diagnosis, staging or treatment upgrade) were collected, thereby evaluating the added value of the 344° panoramic-view (lesions detected by camera A and B) over the standard 172°-view (lesions detected by one camera only). Results Among 41 patients (aged 43 ± 20 years), 73% underwent CE for suspected CD and 27% for established CD. The rate of complete enteroscopy was 90%. No technical failure or retention occurred. Compared to the standard 172° view, the panoramic 344°-view revealed a greater number of patients with a relevant lesion (56.1% vs. 39.0%; P  = 0.023), resulting in higher Lewis score (222,8 vs. 185.7; P  = 0.031), and improved clinical management (48.8% vs. 31.7%, P  = 0.023). Conclusions The panoramic 344°-view increases small-bowel CE accuracy, thereby improving the clinical management of CD patients with mild small-bowel active disease. This system should be regarded as a new standard for both small-bowel diagnosis and monitoring in inflammatory bowel diseases.
    Type of Medium: Online Resource
    ISSN: 1471-230X
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2020
    detail.hit.zdb_id: 2041351-8
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: Frontiers in Medical Technology, Frontiers Media SA, Vol. 4 ( 2022-11-28)
    Abstract: Crohn's disease (CD) is a potentially debilitating condition that burdens Italian healthcare substantially. The symptomatic management relies on prompt therapy adjustment to reduce flares and follow-up diagnostic inputs to maximise remission. Capsule endoscopy (CE) has introduced advantages in CD diagnostics, allowing the direct inspection of the entire gastrointestinal mucosa. The diagnostic procedure is comparable in effort to standard ileocolonoscopy (IC) but requires no anaesthesia. Whether CE follow-up improves clinical outcomes remains to be defined. Objectives To provide a preliminary evaluation of CE in terms of clinical outcomes with respect to the standard of care ileocolonoscopy/MRE in Italy. Methods This retrospective analysis utilises anonymised, monocentric data from the S. Orsola-Malpighi Hospital IBD database in Bologna, Italy, collected between 1999 and 2019. Out of 421 adult patient records, 100 were included in the analysis (50 per arm, matched per demographic and clinical characteristics). The CE represented the intervention arm, whereas ileocolonoscopy/magnetic resonance enterography was the standard of care. The use of biologics, symptomatology course, and surgery were the outcomes. Results The two techniques performed similarly overall. In general, no significant difference emerged in the use of biologics. The use of biologics appears reduced in the CE group, only in L4 patients after the first follow-up year. Similarly, surgery was seemingly less frequent among L4 patients in the CE group. No difference was found between groups in flare occurrence and duration. CE patients might have experienced longer and earlier first remissions, but no long-term difference persisted. Conclusions The CE group showed an apparent reduction in biologics and surgery, limiting to L4 diagnoses. More extensive, prospective, multicentre, randomised studies must corroborate these preliminary findings.
    Type of Medium: Online Resource
    ISSN: 2673-3129
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2022
    detail.hit.zdb_id: 3034618-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Wiley ; 2017
    In:  Journal of Gastroenterology and Hepatology Vol. 32, No. 7 ( 2017-07), p. 1295-1302
    In: Journal of Gastroenterology and Hepatology, Wiley, Vol. 32, No. 7 ( 2017-07), p. 1295-1302
    Abstract: Proton pump inhibitors are among the most commonly prescribed classes of drugs, and their use is increasing, in particular for long‐term treatment, often being over‐prescribed and used for inappropriate conditions. In recent years, considerable attention has been directed towards a wide range of adverse effects, and even when a potential underlying biological mechanism is plausible, the clinical evidence of the adverse effect is often weak. Several long‐term side effects have been investigated ranging from interaction with other drugs, increased risk of infection, reduced intestinal absorption of vitamins and minerals, and more recently kidney damage and dementia. The most recent literature regarding these adverse effects and their association with long‐term proton pump inhibitor treatment is reviewed, and the mechanisms through which these possible complications might develop are discussed.
    Type of Medium: Online Resource
    ISSN: 0815-9319 , 1440-1746
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2017
    detail.hit.zdb_id: 2006782-3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages