In:
Annals of the Rheumatic Diseases, BMJ, Vol. 79, No. Suppl 1 ( 2020-06), p. 1830.1-1830
Abstract:
The monitoring of bone mineral density (BMD) is a key aspect for patients undergoing pharmacological treatments that might cause BMD changes at non-physiological rates. At present, the short-term follow-up of patients under treatment in terms of BMD change with time remains an unmet clinical need, since the current techniques, including the gold standard dual X-ray absorptiometry (DXA), require at least 1 year between two consecutive measurements [1]. Therefore, an effective strategy for the assessment of BMD should guarantee high accuracy, precision and repeatability of the measurements. Objectives: The aim is to assess the influence of the variation 1) in patient position, 2) operator (both intra- and inter-) and 3) device on the REMS performance at lumbar spine and femoral neck. Methods: 210 women were enrolled, divided in 7 groups of 30-patient each for the assessment of the parameters of interest, i.e. inter-device, intra- and inter-operator repeatability for lumbar spine scans and inter-patient position, inter-device, intra- and inter-operator repeatability for femoral neck scans. All patients underwent 2 REMS scans at lumbar spine or femoral neck, performed by the same operator or by 2 different operators or by the same operator using 2 different devices or in different patient position (i.e. supine without constraints or with a constrained 25°-rotation of the leg). The percentage coefficient of variation (CV%) with 95% confidence interval and least significant change for a 95% confidence level (LSC) have been calculated. Results: For lumbar spine, intra-operator repeatability resulted in CV%=0.37% (95%CI: 0.26%-0.48%), with LSC=1.02%, inter-operator repeatability resulted in CV%=0.55% (95% CI: 0.42%-0.68%), with LSC=1.52%, inter-device repeatability resulted in CV%=0.53% (95% CI: 0.40%-0.66%), with LSC=1.47%. For femoral neck, intra-operator repeatability resulted in CV%=0.33% (95%CI: 0.23%-0.43%), with LSC=0.91%, inter-operator repeatability resulted in CV%=0.47% (95% CI: 0.35%-0.59%), with LSC=1.30%, inter-device repeatability resulted in CV%=0.42% (95% CI: 0.30%-0.51%), with LSC=1.16%, inter-patient position repeatability resulted in CV%=0.24% (95% CI: 0.18%-0.30%), with LSC=0.66%. Conclusion: REMS densitometry is highly precise for both anatomical sites, showing high performance in repeatability. These results suggest that REMS might be a suitable technology for short-term monitoring. Moreover, thanks to its ionizing radiation-free approach, it might be applied for population mass investigations and prevention programs also in paediatric patients and pregnant women. References: Note : Carla Caffarelli, Giovanni Adami § , Giovanni Arioli § , Gerolamo Bianchi § , Maria Luisa Brandi § , Sergio Casciaro § , Luisella Cianferotti § , Delia Ciardo § , Francesco Conversano § , Davide Gatti § , Giuseppe Girasole § , Monica Manfredini § , Maurizio Muratore § , Paola Pisani § , Eugenio Quarta § , Laura Quarta § , Stefano Gonnelli § Equal contributors listed in alphabetical order Disclosure of Interests: Carla Caffarelli: None declared, Giovanni Adami: None declared, Giovanni Arioli *: None declared, Gerolamo Bianchi Grant/research support from: Celgene, Consultant of: Amgen, Janssen, Merck Sharp & Dohme, Novartis, UCB, Speakers bureau: Abbvie, Abiogen, Alfa-Sigma, Amgen, BMS, Celgene, Chiesi, Eli Lilly, GSK, Janssen, Medac, Merck Sharp & Dohme, Novartis, Pfizer, Roche, Sanofi Genzyme, Servier, UCB, Maria Luisa Brandi: None declared, Sergio Casciaro: None declared, Luisella Cianferotti: None declared, Delia Ciardo: None declared, Francesco Conversano: None declared, Davide Gatti Speakers bureau: Davide Gatti reports personal fees from Abiogen, Amgen, Janssen-Cilag, Mundipharma, outside the submitted work., Giuseppe Girasole: None declared, Monica Manfedini: None declared, Maurizio Muratore: None declared, Paola Pisani: None declared, Eugenio Quarta: None declared, Laura Quarta: None declared, Stefano Gonnelli: None declared
Type of Medium:
Online Resource
ISSN:
0003-4967
,
1468-2060
DOI:
10.1136/annrheumdis-2020-eular.4553
Language:
English
Publisher:
BMJ
Publication Date:
2020
detail.hit.zdb_id:
1481557-6
Bookmarklink