Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Type of Medium
Publisher
Person/Organisation
Language
Years
  • 1
    Online Resource
    Online Resource
    Wiley ; 2004
    In:  Clinical Implant Dentistry and Related Research Vol. 6, No. 3 ( 2004-09), p. 174-180
    In: Clinical Implant Dentistry and Related Research, Wiley, Vol. 6, No. 3 ( 2004-09), p. 174-180
    Abstract: Background : The CrescoTi Precision® (CTiP) method (CrescoTi Systems, Lausanne, Switzerland) has been introduced as an alternative method for the fabrication of precisely fitting titanium frameworks. The method is supposed to be used with all major implant systems, without the need for abutments. Purpose : The objectives of this clinical and radiographic retrospective follow‐up study were to report the clinical performances of “CTiP‐fabricated” frameworks that are screw retained directly to Brånemark implants as opposed to Brånemark implant/abutment assemblies (Nobel Biocare AB, Gothenburg, Sweden) and to compare the clinical outcomes of these two modalities. Materials and Methods : Thirty‐six patients were provided with 46 fixed prostheses supported by 207 Brånemark regular‐platform implants. Twenty‐seven prostheses were placed on implant/abutment assemblies, and 19 were placed directly at “implant level.” The prostheses had been in function for 5 to 8 years at the time of the final examinations. Results : Three patients did not attend the final examination. All 43 prostheses in the 33 examined patients were still in function. No major mechanical framework complications were observed during the observation period. One implant was lost after loading. There was no difference in bone loss around the abutment‐free implants when compared with the implants provided with abutments. Conclusions : This long‐term clinical test demonstrated that the CTiP technology constitutes a reliable prosthetic treatment concept in combination with Brånemark implants. The results also revealed that the frameworks could be connected directly to the implants without any negative consequences.
    Type of Medium: Online Resource
    ISSN: 1523-0899 , 1708-8208
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2004
    detail.hit.zdb_id: 2094120-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages