feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    SAGE Publications ; 2015
    In:  Journal of Veterinary Diagnostic Investigation Vol. 27, No. 6 ( 2015-11), p. 716-727
    In: Journal of Veterinary Diagnostic Investigation, SAGE Publications, Vol. 27, No. 6 ( 2015-11), p. 716-727
    Abstract: Thyroxine (T4), free T4 (FT4), and thyrotropin (TSH) concentrations were measured in serum from 693 healthy representatives from 7 dog breeds (Alaskan Malamute, Collie, English Setter, Golden Retriever, Keeshond, Samoyed, or Siberian Husky) to determine whether breed-specific reference intervals (RIs) are warranted. Veterinarians reviewed the health history, performed a physical examination, and approved laboratory data for the enrolled dogs. Many purebred dogs had T4 and FT4 concentrations that were at, or below, the lower limits previously determined for non–breed-specific RIs. Mean concentrations of T4, FT4, and TSH varied significantly among breeds. The range of mean concentration of T4 (19.7 nmol/L [1.53 µg/dL] in English Setters to 29.0 nmol/L [2.25 µg/dL] in Keeshonds) and FT4 (12.6 pmol/L [0.98 ng/dL] in English Setters to 20.2 pmol/L [1.57 ng/dL] in Samoyeds) was considerable. Median TSH values ranged from 6.10 mIU/L (0.07 ng/mL; Alaskan Malamute and Golden Retriever) to 17.6 mIU/L (0.26 ng/mL; Collie). Mean T4 and FT4 concentrations were higher in females. Increasing age was associated with decreasing T4 and FT4, and increasing TSH concentration. The substantial ranges across breeds of measures of central tendency (mean, median) for all hormones indicate that breed-specific RIs are warranted. RIs encompassing the central 95% of reference values for all breeds combined, and for individual breeds, were calculated using nonparametric (TSH) and robust (T4, FT4) methods. Use of breed-specific RIs in combination with careful attention to the potential for pre-analytical and analytical variability in test results will improve thyroid function assessment in these breeds.
    Type of Medium: Online Resource
    ISSN: 1040-6387 , 1943-4936
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2015
    detail.hit.zdb_id: 2265211-5
    SSG: 22
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: Scientific Reports, Springer Science and Business Media LLC, Vol. 11, No. 1 ( 2021-01-27)
    Abstract: Cytokine profiling is a valuable tool for monitoring immune responses associated with disease and treatment. This study assessed the impact of sex and sedation on serum cytokines in healthy nonhuman primates (NHPs). Twenty-three cytokines were measured from serum using a bead-based multiplex assay. Assay validation for precision, sensitivity, recovery, linearity, and stability was performed. Samples from male and female cynomolgus and rhesus macaques either cooperating or sedated were compared. All cytokines except TNFα demonstrated acceptable sensitivity and precision, with variable recovery and linearity. IFNγ, IL-2, IL-5, IL-6, IL-8, IL-12/23 (p40), IL-13, IL-15, MCP-1, TGFα, VEGF met acceptance criteria; G-CSF, IL-4, IL-10, MIP1α, sCD40L were marginal. Higher cytokine levels were observed in females and cytokine levels were blunted in sedated NHPs when compared to awake cooperating NHPs. Significant differences observed in cytokines related to sex, species, or imposed by handling highlight the importance of model design on translational relevance for clinical settings.
    Type of Medium: Online Resource
    ISSN: 2045-2322
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2021
    detail.hit.zdb_id: 2615211-3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    In: Journal of Biomolecular Techniques : JBT, Association of Biomolecular Resource Facilities, Vol. 31, No. 1 ( 2020-4), p. 11-26
    Type of Medium: Online Resource
    ISSN: 1524-0215 , 1943-4731
    Language: Unknown
    Publisher: Association of Biomolecular Resource Facilities
    Publication Date: 2020
    detail.hit.zdb_id: 2116011-9
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Association of Biomolecular Resource Facilities ; 2019
    In:  Journal of Biomolecular Techniques : JBT Vol. 30, No. 3 ( 2019-9), p. 36-44
    In: Journal of Biomolecular Techniques : JBT, Association of Biomolecular Resource Facilities, Vol. 30, No. 3 ( 2019-9), p. 36-44
    Type of Medium: Online Resource
    ISSN: 1524-0215 , 1943-4731
    Language: Unknown
    Publisher: Association of Biomolecular Resource Facilities
    Publication Date: 2019
    detail.hit.zdb_id: 2116011-9
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    In: Xenotransplantation, Wiley, Vol. 24, No. 5 ( 2017-09)
    Abstract: C‐peptide concentration is widely used as a marker of insulin secretion and is especially relevant in evaluating islet graft function following transplantation, because its measurement is not confounded by the presence of exogenous insulin. To address the shortage of human islet donors, the use of porcine islets has been proposed as a possible solution and the stringent pig‐to‐non‐human primate ( NHP ) model is often the most relevant for pre‐clinical evaluation of the potential for diabetes reversal resulting from an islet xenograft. The Millipore radioimmunoassay ( RIA ) was exclusively used to measure porcine C‐peptide ( PCP ) until 2013 when the assay was discontinued and subsequently a commercially available enzyme‐linked immunosorbent assay ( ELISA ) from Mercodia has been widely adopted. Both assays have been used in pre‐clinical trials evaluating the therapeutic potential of xenograft products in reversing diabetes in the pig‐to‐ NHP model, to interpret data in a comparable way it may be useful to perform a harmonization of C‐peptide measurements. Methods We performed a method comparison by determining the PCP concentration in 620 serum samples collected from 20 diabetic cynomolgus macaques transplanted with adult porcine islets. All analyses were performed according to manufacturer instructions. Results With both assays, we demonstrated an acceptable detection limit, precision, and recovery. Linearity of the ELISA met acceptance criteria at all concentrations tested while linearity of the RIA only met acceptance criteria at five of the eight concentrations tested. The RIA had a detection limit of 0.16 ng/ mL , and recovery ranged from 82% to 96% and met linearity acceptance criteria at 0.35 ng/ mL and from 0.78 to 2.33 ng/ mL . The ELISA had a detection limit of 0.03 ng/ mL , and recovery ranged from 81% to 115% and met linearity acceptance criteria from 0.08 to 0.85 ng/ mL . Both assays had intra‐assay precision 〈 11% and inter‐assay precision 〈 14%. PCP concentration measured by ELISA demonstrated a significant correlation with RIA ( R 2 =.9721, P 〈 .0001). This strong correlation supports use of the regression equation y =2.029 x +0.0897 to transform ELISA data to RIA or inversely y =0.4930 x −0.0456 to convert RIA data to ELISA for direct comparison between assays in the concentration range of 0‐3.0 ng/ mL . Measured C‐peptide concentration was lower with the ELISA than with the RIA ; individual measurements plotted against the averages of the pair demonstrated that the variability from the mean strongly depended on increasing concentration. Conclusions Porcine C‐peptide can be reliably measured in NHP serum using the Mercodia ELISA , making this assay interchangeable with the Millipore RIA . Inherent differences in antibody affinity and calibration factors may explain the lower ELISA values as compared to the RIA ; however without access to a traceable reference standard, it is not possible to determine which assay is most accurate. Regression modeling resulted in a correction factor appropriate for conversion of ELISA data to RIA ‐equivalent data facilitating comparison of assay results longitudinally and between groups.
    Type of Medium: Online Resource
    ISSN: 0908-665X , 1399-3089
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2017
    detail.hit.zdb_id: 2011995-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    In: Xenotransplantation, Wiley, Vol. 22, No. 1 ( 2015-01), p. 62-69
    Abstract: Pre‐clinical demonstration of porcine islet graft function is necessary to support the clinical transplantation of pig islets. C‐peptide concentration is an especially useful marker of insulin secretion, because its measurement is not confounded by the presence of exogenous insulin. To measure porcine C‐peptide ( PCP ), researchers in the field exclusively used the Millipore (previously Linco Research) radioimmunoassay ( RIA ) until 2011, when Mercodia released an alternative enzyme‐linked immunosorbent assay ( ELISA ). (At the end of 2013, the Millipore RIA was withdrawn from the market for commercial reasons.) In our current study, to directly compare these two assays, we performed validation studies on each. We also performed interlaboratory comparisons. Then, to determine the level of agreement between the assays, we analyzed the porcine serum C‐peptide concentration measurement results obtained from each assay. Methods Using pre‐established method validation acceptance criteria, we determined and evaluated the detection limit, sensitivity, precision, linearity, and recovery of the two commercially available PCP assays described above ( ELISA and RIA ). After validation requirements were met, we performed a method comparison by determining C‐peptide concentration in 60 serum samples collected from 31 normal, healthy adult Landrace pigs in the fasting state; a subset underwent an intravenous glucose challenge test, to stimulate the typical physiologic range of C‐peptide. All analyses were performed according to manufacturer instructions. To compare the assays, we used Deming regression analysis. Results Both assays met acceptance criteria. The RIA had a sensitivity of 0.1 ng/ml; it was linear to 2.9 ng/ml. The ELISA had a detection limit of 0.03 ng/ml; it was linear to 1.2 ng/ml. Recovery ranged from 89 to 113% with both assays. The coefficient of variability was 8% in interlaboratory comparisons. Deming regression analysis directly comparing both assays revealed significant correlation between them (before log‐transformation: R 2  = 0.9803, P   〈   0.0001; after log‐transformation: R 2  = 0.9727, P   〈   0.0001). Measured C‐peptide concentration was lower with the ELISA than with the RIA; individual measurements plotted against the averages of the pair demonstrated that the variability from the mean strongly depended on increasing concentration. To transform ELISA data, we used the standard regression equation y  = 2.191 x  + 0.1119 and the log‐transformed regression equation y  = 0.8101 x  + 0.7502. Both the transformed and the log‐transformed (exponential) values approximated the measured RIA levels with a high degree of accuracy in the concentration range of 0 to 1.0 ng/ml. Conclusions Porcine C‐peptide concentration can be reliably measured in porcine serum samples with either assay ( ELISA or RIA ). However, the C‐peptide results generated by these two assays are not equivalent. Therefore, assay bias must be considered before directly comparing pre‐clinical studies that used either of these assays. We determined that harmonization between the assays is appropriate in a specific concentration range. Outside of that range, we do not know whether a linear correction function can be more broadly applied. The variation between the two assays may be related to calibration or reagent factors. To determine which assay is truly more accurate and to effectively compare interlaboratory results, we will need a traceable reference standard.
    Type of Medium: Online Resource
    ISSN: 0908-665X , 1399-3089
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2015
    detail.hit.zdb_id: 2011995-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    In: American Journal of Veterinary Research, American Veterinary Medical Association (AVMA), Vol. 72, No. 8 ( 2011-08), p. 1052-1058
    Abstract: Objective —To evaluate and compare circulating concentrations of islet amyloid polypeptide (IAPP), insulin, and glucose in nondiabetic cats classified by body condition score (BCS) and in cats with naturally occurring diabetes mellitus. Animals —109 (82 nondiabetic, 21 nonketoacidotic diabetic, and 6 ketoacidotic diabetic) cats. Procedures —Cats were examined and BCSs were assessed on a scale of 1 to 9. After food was withheld for 12 hours, blood was collected and plasma concentrations of IAPP and serum concentrations of insulin and glucose were measured. Differences in these values were evaluated among nondiabetic cats grouped according to BCS and in diabetic cats grouped as ketoacidotic or nonketoacidotic on the basis of clinicopathologic findings. Correlations were determined among variables. Results —In nondiabetic cats, BCS was significantly and positively correlated with circulating IAPP and insulin concentrations. Mean plasma IAPP concentrations were significantly different between cats with BCSs of 5 and 7, and mean serum insulin concentrations were significantly different between cats with BCSs of 5 and 8. Serum glucose concentrations were not significantly different among nondiabetic cats. Mean IAPP concentrations were similar between nonketoacidotic diabetic cats and nondiabetic cats with BCSs of 8 or 9. Mean IAPP concentrations were significantly reduced in ketoacidotic diabetic cats, compared with those of nondiabetic cats with BCSs of 6 through 8 and of nonketoacidotic diabetic cats. Conclusions and Clinical Relevance —Results indicated that increased BCS (a measure of obesity) is associated with increased circulating concentrations of IAPP and insulin in nondiabetic cats.
    Type of Medium: Online Resource
    ISSN: 0002-9645
    Language: Unknown
    Publisher: American Veterinary Medical Association (AVMA)
    Publication Date: 2011
    detail.hit.zdb_id: 2056942-7
    SSG: 22
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Online Resource
    Online Resource
    American Veterinary Medical Association (AVMA) ; 2009
    In:  Journal of the American Veterinary Medical Association Vol. 234, No. 6 ( 2009-03-15), p. 767-770
    In: Journal of the American Veterinary Medical Association, American Veterinary Medical Association (AVMA), Vol. 234, No. 6 ( 2009-03-15), p. 767-770
    Abstract: Objective —To determine whether dogs with renal failure have higher serum cardiac troponin I (cTnI) concentrations than healthy dogs. Design —Case-control study. Animals —31 dogs with renal failure and 51 healthy dogs. Procedures —Serum concentrations of creatinine and cardiac troponin I, urine specific gravity, and systolic arterial blood pressure were measured for all dogs. Dogs underwent a standardized physical examination, and any dog with evidence of cardiovascular disease or other nonrenal disease was excluded from final analyses. Dogs were considered to be in renal failure when the serum creatinine concentration was ≥ 3.0 mg/dL, urine specific gravity was between 1.007 and 1.030, and renal failure had been clinically diagnosed. Results —Dogs with renal failure had significantly higher serum cTnI concentrations (median, 0.35 ng/mL) than did healthy dogs (0.20 ng/mL). The renal failure group also had a significantly higher median systolic blood pressure (156 mm Hg) than did healthy dogs (138 mm Hg), although serum cTnI concentration was not correlated with systolic blood pressure in dogs with renal failure. There was no significant difference in age between dogs with renal failure and healthy dogs, but dogs with renal failure had significantly higher serum creatinine concentration and lower urine specific gravity. Conclusions and Clinical Relevance —Although dogs with renal failure did not have overt clinical signs of cardiac disease, they had high serum cTnI concentrations, which may have been associated with subclinical cardiovascular disease. The cause of the high serum cTnI concentration in these dogs requires additional investigation.
    Type of Medium: Online Resource
    ISSN: 0003-1488
    Language: Unknown
    Publisher: American Veterinary Medical Association (AVMA)
    Publication Date: 2009
    detail.hit.zdb_id: 2904887-4
    SSG: 22
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Online Resource
    Online Resource
    Elsevier BV ; 2006
    In:  Theriogenology Vol. 66, No. 3 ( 2006-8), p. 592-598
    In: Theriogenology, Elsevier BV, Vol. 66, No. 3 ( 2006-8), p. 592-598
    Type of Medium: Online Resource
    ISSN: 0093-691X
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2006
    detail.hit.zdb_id: 1498777-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Online Resource
    Online Resource
    American Veterinary Medical Association (AVMA) ; 2012
    In:  American Journal of Veterinary Research Vol. 73, No. 4 ( 2012-04), p. 529-538
    In: American Journal of Veterinary Research, American Veterinary Medical Association (AVMA), Vol. 73, No. 4 ( 2012-04), p. 529-538
    Abstract: Objective —To determine the effects of hypothyroidism on insulin sensitivity, glucose tolerance, and concentrations of hormones counter-regulatory to insulin in dogs. Animals —8 anestrous mixed-breed bitches with experimentally induced hypothyroidism and 8 euthyroid control dogs. Procedures —The insulin-modified frequently sampled IV glucose tolerance test and minimal model analysis were used to determine basal plasma insulin and glucose concentrations, acute insulin response to glucose, insulin sensitivity, glucose effectiveness, and disposition index. Growth hormone response was assessed by stimulation and suppression tests. Additionally, basal serum growth hormone (GH) and insulin-like growth factor-1 (IGF-1) concentrations and urine cortisol-to-creatinine concentration ratios were measured and dual energy x-ray absorptiometry was performed to evaluate body composition. Results —Insulin sensitivity was lower in the hypothyroid group than in the euthyroid group, whereas acute insulin response to glucose was higher. Glucose effectiveness and disposition index were not different between groups. Basal serum GH and IGF-1 concentrations as well as abdominal fat content were high in hypothyroid dogs, but urine cortisol-to-creatinine concentration ratios were unchanged. Conclusions and Clinical Relevance —Hypothyroidism appeared to negatively affect glucose homeostasis by inducing insulin resistance, but overall glucose tolerance was maintained by increased insulin secretion in hypothyroid dogs. Possible factors affecting insulin sensitivity are high serum GH and IGF-1 concentrations and an increase in abdominal fat. In dogs with diseases involving impaired insulin secretion such as diabetes mellitus, concurrent hypothyroidism can have important clinical implications.
    Type of Medium: Online Resource
    ISSN: 0002-9645
    Language: Unknown
    Publisher: American Veterinary Medical Association (AVMA)
    Publication Date: 2012
    detail.hit.zdb_id: 2056942-7
    SSG: 22
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages