In:
Investigative Radiology, Ovid Technologies (Wolters Kluwer Health), Vol. 57, No. 8 ( 2022-8), p. 536-543
Abstract:
The aim of this study was to evaluate coronary computed tomography angiography (CCTA)-based in vitro and in vivo coronary artery calcium scoring (CACS) using a novel virtual noniodine reconstruction (PureCalcium) on a clinical first-generation photon-counting detector–computed tomography system compared with virtual noncontrast (VNC) reconstructions and true noncontrast (TNC) acquisitions. Materials and Methods Although CACS and CCTA are well-established techniques for the assessment of coronary artery disease, they are complementary acquisitions, translating into increased scan time and patient radiation dose. Hence, accurate CACS derived from a single CCTA acquisition would be highly desirable. In this study, CACS based on PureCalcium, VNC, and TNC, reconstructions was evaluated in a CACS phantom and in 67 patients (70 [59/80] years, 58.2% male) undergoing CCTA on a first-generation photon counting detector–computed tomography system. Coronary artery calcium scores were quantified for the 3 reconstructions and compared using Wilcoxon test. Agreement was evaluated by Pearson and Spearman correlation and Bland-Altman analysis. Classification of coronary artery calcium score categories (0, 1–10, 11–100, 101–400, and 〉 400) was compared using Cohen κ . Results Phantom studies demonstrated strong agreement between CACS PureCalcium and CACS TNC (60.7 ± 90.6 vs 67.3 ± 88.3, P = 0.01, r = 0.98, intraclass correlation [ICC] = 0.98; mean bias, 6.6; limits of agreement [LoA] , −39.8/26.6), whereas CACS VNC showed a significant underestimation (42.4 ± 75.3 vs 67.3 ± 88.3, P 〈 0.001, r = 0.94, ICC = 0.89; mean bias, 24.9; LoA, −87.1/37.2). In vivo comparison confirmed a high correlation but revealed an underestimation of CACS PureCalcium (169.3 [0.7/969.4] vs 232.2 [26.5/1112.2] , P 〈 0.001, r = 0.97, ICC = 0.98; mean bias, −113.5; LoA, −470.2/243.2). In comparison, CACS VNC showed a similarly high correlation, but a substantially larger underestimation (24.3 [0/272.3] vs 232.2 [26.5/1112.2] , P 〈 0.001, r = 0.97, ICC = 0.54; mean bias, −551.6; LoA, −2037.5/934.4). CACS PureCalcium showed superior agreement of CACS classification ( κ = 0.88) than CACS VNC ( κ = 0.60). Conclusions The accuracy of CACS quantification and classification based on PureCalcium reconstructions of CCTA outperforms CACS derived from VNC reconstructions.
Type of Medium:
Online Resource
ISSN:
1536-0210
,
0020-9996
DOI:
10.1097/RLI.0000000000000868
Language:
English
Publisher:
Ovid Technologies (Wolters Kluwer Health)
Publication Date:
2022
detail.hit.zdb_id:
2041543-6
Bookmarklink