Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Sexual Medicine, Oxford University Press (OUP), Vol. 6, No. 1 ( 2018-03-01), p. 24-29
    Abstract: The inflatable penile prosthesis (IPP) is typically the preferred implant for Peyronie’s disease (PD) and malleable penile prostheses (MPPs) have been discouraged. Aims To evaluate the effectiveness and patient satisfaction of the MPP vs IPP in patients with PD. Methods Men with PD and erectile dysfunction who elected for penile implant surgery constituted the study population. Preoperatively, demographic and comorbidity parameters were recorded. Curvature was measured with a goniometer at maximum rigidity after intracavernosal injection of a vasoactive agent. Postoperatively, overall satisfaction was measured at 3, 6, 12, and 24 months on 5-point Likert scale from 1 (dissatisfied) to 5 (very satisfied). Results 166 men with a mean age of 59 ± 10 years were analyzed. The mean preoperative curvature in the entire cohort was 65° (range = 30–130°). 94% of patients with MPP had total resolution of their curvature at the end of the operation, whereas 8 patients (6%) had residual curvature (25–40°). In the IPP group 25 of 30 (83.3%) had a straight penis at the end of surgery, whereas 5 of 30 (16.7%) had residual curvature, with the mean magnitude being 33° in the MPP group and 30° in the IPP group. 86% of all patients had diabetes. There were no differences between the 2 implant groups in age, hemoglobin A1c, body mass index, or smoking status. The mean patient satisfaction was 4.42 ± 0.70 (range = 2–5) and there was no difference between the 2 groups. The mean follow-up period was 23.4 months (range = 6–29 months). Conclusion We found that the MPP is as effective as the IPP in curvature correction in patients with PD, with similar patient satisfaction for the 2 groups.
    Type of Medium: Online Resource
    ISSN: 2050-1161
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2018
    detail.hit.zdb_id: 2734882-9
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: BJU International, Wiley, Vol. 121, No. 2 ( 2018-02), p. 293-300
    Abstract: To re‐evaluate the role of diabetes mellitus ( DM ) as a risk factor for penile implant infection by exploring the association between glycated haemoglobin (HbA1c) levels and penile implant infection rates and to define a threshold value that predicts implant infection. Patients and Methods We conducted a multicentre prospective study including all patients undergoing penile implant surgery between 2009 and 2015. Preoperative, perioperative and postoperative management were identical for the entire cohort. Univariate analysis was performed to define predictors of implant infection. The HbA1c levels were analysed as continuous variables and sequential analysis was conducted using 0.5% increments to define a threshold level predicting implant infection. Multivariable analysis was performed with the following factors entered in the model: DM , HbA1C level, patient age, implant type, number of vascular risk factors ( VRF s), presence of Peyronie's disease ( PD ), body mass index ( BMI ), and surgeon volume. A receiver operating characteristic ( ROC ) curve was generated to define the optimal HbA1C threshold for infection prediction. Results In all, 902 implant procedures were performed over the study period. The mean patient age was 56.6 years. The mean HbA1c level was 8.0%, with 81% of men having a HbA1c level of 〉 6%. In all, 685 (76%) implants were malleable and 217 (24%) were inflatable devices; 302 (33.5%) patients also had a diagnosis of PD . The overall infection rate was 8.9% (80/902). Patients who had implant infection had significantly higher mean HbA1c levels, 9.5% vs 7.8% ( P 〈 0.001). Grouping the cases by HbA1c level, we found infection rates were: 1.3% with HbA1c level of 〈 6.5%, 1.5% for 6.5–7.5%, 6.5% for 7.6–8.5%, 14.7% for 8.6–9.5%, 22.4% for 〉 9.5% ( P 〈 0.001). Patient age, implant type, and number of VRF s were not predictive. Predictors defined on multivariable analysis were: PD , high BMI , and high HbA1c level, whilst a high‐volume surgeon had a protective effect and was associated with a reduced infection risk. Using ROC analysis, we determined that a HbA1c threshold level of 8.5% predicted infection with a sensitivity of 80% and a specificity of 65%. Conclusion Uncontrolled DM is associated with increased risk of infection after penile implant surgery. The risk is directly related to the HbA1c level. A threshold HbA1c level of 8.5% is suggested for clinical use to identify patients at increased infection risk.
    Type of Medium: Online Resource
    ISSN: 1464-4096 , 1464-410X
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2018
    detail.hit.zdb_id: 2019983-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages