    In: Medical Physics, Wiley, Vol. 48, No. 8 ( 2021-08), p. 4148-4159
    Abstract: The implementation of volumetric in‐room imaging for online adaptive radiotherapy makes extensive testing of this image data for treatment planning necessary. Especially for proton beams the higher sensitivity to stopping power properties of the tissue results in more stringent requirements. Current approaches mainly focus on recalculation of the plans on the new image data, lacking experimental verification, and ignoring the impact on the plan re‐optimization process. The aim of this study was to use gel and film dosimetry coupled with a three‐dimensional (3D) printed head phantom (based on the planning CT of the patient) for 3D range verification of intensity‐corrected cone beam computed tomography (CBCT) image data for adaptive proton therapy. Methods Single field uniform dose pencil beam scanning proton plans were optimized for three different patients on the patients’ planning CT (planCT) and the patients’ intensity‐corrected CBCT (scCBCT) for the same target volume using the same optimization constraints. The CBCTs were corrected on projection level using the planCT as a prior. The dose optimized on planCT and recalculated on scCBCT was compared in terms of proton range differences (80% distal fall‐off, recalculation). Moreover, the dose distribution resulting from recalculation of the scCBCT‐optimized plan on the planCT and the original planCT dose distribution were compared (simulation). Finally, the two plans of each patient were irradiated on the corresponding patient‐specific 3D printed head phantom using gel dosimetry inserts for one patient and film dosimetry for all three patients. Range differences were extracted from the measured dose distributions. The measured and the simulated range differences were corrected for range differences originating from the initial plans and evaluated. Results The simulation approach showed high agreement with the standard recalculation approach. The median values of the range differences of these two methods agreed within 0.1 mm and the interquartile ranges (IQRs) within 0.3 mm for all three patients. The range differences of the film measurement were accurately matching with the simulation approach in the film plane. The median values of these range differences deviated less than 0.1 mm and the IQRs less than 0.4 mm. For the full 3D evaluation of the gel range differences, the median value and IQR matched those of the simulation approach within 0.7 and 0.5 mm, respectively. scCBCT‐ and planCT‐based dose distributions were found to have a range agreement better than 3 mm (median and IQR) for all considered scenarios (recalculation, simulation, and measurement). Conclusions The results of this initial study indicate that an online adaptive proton workflow based on scatter‐corrected CBCT image data for head irradiations is feasible. The novel presented measurement‐ and simulation‐based method was shown to be equivalent to the standard literature recalculation approach. Additionally, it has the capability to catch effects of image differences on the treatment plan optimization. This makes the measurement‐based approach particularly interesting for quality assurance of CBCT‐based online adaptive proton therapy. The observed uncertainties could be kept within those of the registration and positioning. The proposed validation could also be applied for other alternative in‐room images, e.g. for MR‐based pseudoCTs.
    Type of Medium: Online Resource
    ISSN: 0094-2405 , 2473-4209
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2021
    detail.hit.zdb_id: 1466421-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: Physics in Medicine & Biology, IOP Publishing, Vol. 66, No. 5 ( 2021-03-07), p. 055006-
    Abstract: Real-time motion monitoring of lung tumors with low-field magnetic resonance imaging-guided linear accelerators (MR-Linacs) is currently limited to sagittal 2D cine magnetic resonance imaging (MRI). To provide input data for improved intrafractional and interfractional adaptive radiotherapy, the 4D anatomy has to be inferred from data with lower dimensionality. The purpose of this study was to experimentally validate a previously proposed propagation method that provides continuous time-resolved estimated 4D-MRI based on orthogonal cine MRI for a low-field MR-Linac. Ex vivo porcine lungs were injected with artificial nodules and mounted in a dedicated phantom that allows for the simulation of periodic and reproducible breathing motion. The phantom was scanned with a research version of a commercial 0.35 T MR-Linac. Respiratory-correlated 4D-MRI were reconstructed and served as ground truth images. Series of interleaved orthogonal slices in sagittal and coronal orientation, intersecting the injected targets, were acquired at 7.3 Hz. Estimated 4D-MRI at 3.65 Hz were created in post-processing using the propagation method and compared to the ground truth 4D-MRI. Eight datasets at different breathing frequencies and motion amplitudes were acquired for three porcine lungs. The overall median (95 t h percentile) deviation between ground truth and estimated deformation vector fields was 2.3 mm (5.7 mm), corresponding to 0.7 (1.6) times the in-plane imaging resolution (3.5 × 3.5 mm 2 ). Median (95 t h percentile) estimated nodule position errors were 1.5 mm (3.8 mm) for nodules intersected by orthogonal slices and 2.1 mm (7.1 mm) for nodules located more than 2 cm away from either of the orthogonal slices. The estimation error depended on the breathing phase, the motion amplitude and the location of the estimated position with respect to the orthogonal slices. By using the propagation method, the 4D motion within the porcine lung phantom could be accurately and robustly estimated. The method could provide valuable information for treatment planning, real-time motion monitoring, treatment adaptation, and post-treatment evaluation of MR-guided radiotherapy treatments.
    Type of Medium: Online Resource
    ISSN: 0031-9155 , 1361-6560
    RVK:
    Language: Unknown
    Publisher: IOP Publishing
    Publication Date: 2021
    detail.hit.zdb_id: 1473501-5
    SSG: 12
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    In: Radiation Oncology, Springer Science and Business Media LLC, Vol. 18, No. 1 ( 2023-04-03)
    Abstract: Hybrid devices that combine radiation therapy and MR-imaging have been introduced in the clinical routine for the treatment of lung cancer. This opened up not only possibilities in terms of accurate tumor tracking, dose delivery and adapted treatment planning, but also functional lung imaging. The aim of this study was to show the feasibility of Non-uniform Fourier Decomposition (NuFD) MRI at a 0.35 T MR-Linac as a potential treatment response assessment tool, and propose two signal normalization strategies for enhancing the reproducibility of the results. Methods Ten healthy volunteers (median age 28 ± 8 years, five female, five male) were repeatedly scanned at a 0.35 T MR-Linac using an optimized 2D+ t balanced steady-state free precession (bSSFP) sequence for two coronal slice positions. Image series were acquired in normal free breathing with breaks inside and outside the scanner as well as deep and shallow breathing. Ventilation- and perfusion-weighted maps were generated for each image series using NuFD. For intra-volunteer ventilation map reproducibility, a normalization factor was defined based on the linear correlation of the ventilation signal and diaphragm position of each scan as well as the diaphragm motion amplitude of a reference scan. This allowed for the correction of signal dependency on the diaphragm motion amplitude, which varies with breathing patterns. The second strategy, which can be used for ventilation and perfusion, eliminates the dependency on the signal amplitude by normalizing the ventilation/perfusion maps with the average ventilation/perfusion signal within a selected region-of-interest (ROI). The position and size dependency of this ROI was analyzed. To evaluate the performance of both approaches, the normalized ventilation/perfusion-weighted maps were compared and the deviation of the mean ventilation/perfusion signal from the reference was calculated for each scan. Wilcoxon signed-rank tests were performed to test whether the normalization methods can significantly improve the reproducibility of the ventilation/perfusion maps. Results The ventilation- and perfusion-weighted maps generated with the NuFD algorithm demonstrated a mostly homogenous distribution of signal intensity as expected for healthy volunteers regardless of the breathing maneuver and slice position. Evaluation of the ROI’s size and position dependency showed small differences in the performance. Applying both normalization strategies improved the reproducibility of the ventilation by reducing the median deviation of all scans to 9.1%, 5.7% and 8.6% for the diaphragm-based, the best and worst performing ROI-based normalization, respectively, compared to 29.5% for the non-normalized scans. The significance of this improvement was confirmed by the Wilcoxon signed rank test with $$p\, 〈 \, 0.01$$ p 〈 0.01 at $$\alpha \, =\, 0.05$$ α = 0.05 . A comparison of the techniques against each other revealed a significant difference in the performance between best ROI-based normalization and worst ROI ( $$p\, =\, 0.01$$ p = 0.01 ) and between best ROI-based normalization and scaling factor ( $$p\, =\, 0.02$$ p = 0.02 ), but not between scaling factor and worst ROI ( $$p\, =\, 0.71$$ p = 0.71 ). Using the ROI-based approach for the perfusion-maps, the uncorrected deviation of 10.2% was reduced to 5.3%, which was shown to be significant ( $$p\, 〈 \, 0.01$$ p 〈 0.01 ). Conclusions Using NuFD for non-contrast enhanced functional lung MRI at a 0.35 T MR-Linac is feasible and produces plausible ventilation- and perfusion-weighted maps for volunteers without history of chronic pulmonary diseases utilizing different breathing patterns. The reproducibility of the results in repeated scans significantly benefits from the introduction of the two normalization strategies, making NuFD a potential candidate for fast and robust early treatment response assessment of lung cancer patients during MR-guided radiotherapy.
    Type of Medium: Online Resource
    ISSN: 1748-717X
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2023
    detail.hit.zdb_id: 2224965-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    In: Oceanography, The Oceanography Society, ( 2021-12-01), p. 10-11
    Type of Medium: Online Resource
    ISSN: 1042-8275
    Language: Unknown
    Publisher: The Oceanography Society
    Publication Date: 2021
    detail.hit.zdb_id: 1167549-4
    detail.hit.zdb_id: 2268693-9
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    In: Radiation Oncology, Springer Science and Business Media LLC, Vol. 18, No. 1 ( 2023-08-14)
    Abstract: Magnetic resonance imaging guided radiotherapy (MRgRT) offers treatment plan adaptation to the anatomy of the day. In the current MRgRT workflow, this requires the time consuming and repetitive task of manual delineation of organs-at-risk (OARs), which is also prone to inter- and intra-observer variability. Therefore, deep learning autosegmentation (DLAS) is becoming increasingly attractive. No investigation of its application to OARs in thoracic magnetic resonance images (MRIs) from MRgRT has been done so far. This study aimed to fill this gap. Materials and methods 122 planning MRIs from patients treated at a 0.35 T MR-Linac were retrospectively collected. Using an 80/19/23 (training/validation/test) split, individual 3D U-Nets for segmentation of the left lung, right lung, heart, aorta, spinal canal and esophagus were trained. These were compared to the clinically used contours based on Dice similarity coefficient (DSC) and Hausdorff distance (HD). They were also graded on their clinical usability by a radiation oncologist. Results Median DSC was 0.96, 0.96, 0.94, 0.90, 0.88 and 0.78 for left lung, right lung, heart, aorta, spinal canal and esophagus, respectively. Median 95th percentile values of the HD were 3.9, 5.3, 5.8, 3.0, 2.6 and 3.5 mm, respectively. The physician preferred the network generated contours over the clinical contours, deeming 85 out of 129 to not require any correction, 25 immediately usable for treatment planning, 15 requiring minor and 4 requiring major corrections. Conclusions We trained 3D U-Nets on clinical MRI planning data which produced accurate delineations in the thoracic region. DLAS contours were preferred over the clinical contours.
    Type of Medium: Online Resource
    ISSN: 1748-717X
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2023
    detail.hit.zdb_id: 2224965-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    In: Medical Physics, Wiley, Vol. 47, No. 4 ( 2020-04), p. 1431-1442
    Abstract: In photon radiotherapy, respiratory‐induced target motion can be accounted for by internal target volumes (ITV) or mid‐ventilation target volumes (midV) defined on the basis of four‐dimensional computed tomography (4D‐CT). Intrinsic limitations of these approaches can result in target volumes that are not representative for the gross tumor volume (GTV) motion over the course of treatment. To address these limitations, we propose a novel patient‐specific ITV definition method based on real‐time 4D magnetic resonance imaging (rt‐4DMRI). Methods Three lung cancer patients underwent weekly rt‐4DMRI scans. A total of 24 datasets were included in this retrospective study. The GTV was contoured on breath‐hold MR images and propagated to all rt‐4DMRI images by deformable image registration. Different targets were created for the first (reference) imaging sessions: ITVs encompassing all GTV positions over the complete (ITV ) or partial acquisition time ( ), ITVs including only voxels with a GTV probability‐of‐presence (POP) of at least 5% ( ) or 10% ( ), and the mid‐ventilation GTV position. Reference planning target volumes ( ) were created by adding margins around the ITVs and midV target volumes. The geometrical overlap of the with from the six to eight subsequent imaging sessions on days n was quantified in terms of the Dice similarity coefficient (DSC), sensitivity [SE: ( )/ ] and precision [PRE: ( )/ ] as surrogates for target coverage and normal tissue sparing. Results Patient‐specific analysis yielded a high variance of the overlap values of , when different periods within the reference imaging session were sampled. The mid‐ventilation‐based PTVs were smaller than the ITV‐based PTVs. While the SE was high for patients with small breathing pattern variations, changes of the median breathing amplitudes in different imaging sessions led to inferior SE values for the mid‐ventilation PTV for one patient. In contrast, and showed higher SE values with a higher robustness against interfractional changes, at the cost of larger target volumes. Conclusions The results indicate that rt‐4DMRI could be valuable for the definition of target volumes based on the GTV POP to achieve a higher robustness against interfractional changes than feasible with today’s 4D‐CT‐based target definition concepts.
    Type of Medium: Online Resource
    ISSN: 0094-2405 , 2473-4209
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2020
    detail.hit.zdb_id: 1466421-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    In: Radiation Oncology, Springer Science and Business Media LLC, Vol. 15, No. 1 ( 2020-12)
    Abstract: The integration of magnetic resonance imaging (MRI) for guidance in external beam radiotherapy has faced significant research and development efforts in recent years. The current availability of linear accelerators with an embedded MRI unit, providing volumetric imaging at excellent soft tissue contrast, is expected to provide novel possibilities in the implementation of image-guided adaptive radiotherapy (IGART) protocols. This study reviews open medical physics issues in MR-guided radiotherapy (MRgRT) implementation, with a focus on current approaches and on the potential for innovation in IGART. Daily imaging in MRgRT provides the ability to visualize the static anatomy, to capture internal tumor motion and to extract quantitative image features for treatment verification and monitoring. Those capabilities enable the use of treatment adaptation, with potential benefits in terms of personalized medicine. The use of online MRI requires dedicated efforts to perform accurate dose measurements and calculations, due to the presence of magnetic fields. Likewise, MRgRT requires dedicated quality assurance (QA) protocols for safe clinical implementation. Reaction to anatomical changes in MRgRT, as visualized on daily images, demands for treatment adaptation concepts, with stringent requirements in terms of fast and accurate validation before the treatment fraction can be delivered. This entails specific challenges in terms of treatment workflow optimization, QA, and verification of the expected delivered dose while the patient is in treatment position. Those challenges require specialized medical physics developments towards the aim of fully exploiting MRI capabilities. Conversely, the use of MRgRT allows for higher confidence in tumor targeting and organs-at-risk (OAR) sparing. The systematic use of MRgRT brings the possibility of leveraging IGART methods for the optimization of tumor targeting and quantitative treatment verification. Although several challenges exist, the intrinsic benefits of MRgRT will provide a deeper understanding of dose delivery effects on an individual basis, with the potential for further treatment personalization.
    Type of Medium: Online Resource
    ISSN: 1748-717X
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2020
    detail.hit.zdb_id: 2224965-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    In: PROTEOMICS, Wiley, Vol. 15, No. 21 ( 2015-11), p. 3648-3661
    Type of Medium: Online Resource
    ISSN: 1615-9853
    Language: English
    Publisher: Wiley
    Publication Date: 2015
    detail.hit.zdb_id: 2037674-1
    SSG: 12
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    In: Physics in Medicine & Biology, IOP Publishing
    Abstract: Objective. To experimentally validate a method to create continuous time-resolved estimated synthetic 4D-computed tomography datasets (tresCTs) based on orthogonal cine MRI data for lung cancer treatments at a magnetic resonance imaging (MRI)-guided linear accelerator (MR-linac). & #xD;Approach. A breathing porcine lung phantom was scanned at a CT scanner and 0.35 T MR-linac. Orthogonal cine MRI series (sagittal/coronal orientation) at 7.3 Hz, intersecting tumor-mimicking gelatin nodules, were deformably registered to mid-exhale 3D-CT and 3D-MRI datasets. The time-resolved deformation vector fields were extrapolated to 3D and applied to a reference synthetic 3D-CT image (sCT ref ), while accounting for breathing phase-dependent lung density variations, to create 82s-long tresCTs at 3.65 Hz. Ten tresCTs were created for ten tracked nodules with different motion patterns in two lungs. For each dataset, a treatment plan was created on the mid-exhale phase of a measured ground truth (GT) respiratory-correlated 4D-CT dataset with the tracked nodule as gross tumor volume (GTV). Each plan was recalculated on the GT 4D-CT, randomly sampled tresCT, and static sCT ref images. Dose distributions for corresponding breathing phases were compared in gamma (2%/2mm) and dose-volume histogram (DVH) parameter analyses. & #xD;Main results. The mean gamma pass rate between all tresCT and GT 4D-CT dose distributions was 98.6%. The mean absolute relative deviations of the tresCT with respect to GT DVH parameters were 1.9%, 1.0%, and 1.4% for the GTV D 98% , D 50% , and D 2% , respectively, 1.0% for the remaining nodules D 50% , and 1.5% for the lung V 20 Gy . The gamma pass rate for the tresCTs was significantly larger (p 〈 0.01), and the GTV D 50% deviations with respect to the GT were significantly smaller (p 〈 0.01) than for the sCT ref . & #xD;Significance. The results suggest that tresCTs could be valuable for time-resolved reconstruction and intrafractional accumulation of the dose to the GTV for lung cancer patients treated at MR-linacs in the future.
    Type of Medium: Online Resource
    ISSN: 0031-9155 , 1361-6560
    RVK:
    Language: Unknown
    Publisher: IOP Publishing
    Publication Date: 2023
    detail.hit.zdb_id: 1473501-5
    SSG: 12
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    In: Zeitschrift für Medizinische Physik, Elsevier BV, Vol. 32, No. 3 ( 2022-08), p. 312-325
    Type of Medium: Online Resource
    ISSN: 0939-3889
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2022
    detail.hit.zdb_id: 2231492-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...