Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    SAGE Publications ; 2020
    In:  Annals of Clinical Biochemistry: International Journal of Laboratory Medicine Vol. 57, No. 1 ( 2020-01), p. 64-68
    In: Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, SAGE Publications, Vol. 57, No. 1 ( 2020-01), p. 64-68
    Abstract: The aim of this work was to determine the frequency of ascorbic acid-positive urine samples and to evaluate the potential risk on patient safety. Materials and methods A total of  27,856 samples submitted for urinalysis in previous year were retrospectively analysed from the laboratory information system. Urinalysis was done on Iris IQ200 analyzer using 11-parameter iChem Velocity test strips. Risk analysis combined the impact of potentially erroneous results (due to ascorbic acid interference) on patient safety (severity – S) with their frequency (occurrence – O). Potential risk was identified as high, intermediate and low. Results One thousand one hundred and ninety-nine (4.3%) and 1646 (5.9%) samples were mildly (20 mg/dL, 1+) and highly positive (40 mg/dL, 2+) for ascorbic acid, respectively. Severity (S1 to S5) was assigned to four possible errors: false-negative glucose (U-Glc: S2), blood (U-Hb: S5), nitrite (U-Nit: S4) and bilirubin (U-Bil: S1). Based on the frequency of errors, occurrence was categorized as: O2 for U-Glc, and O3 for U-Bil, U-Nit and U-Hb. The risk analysis matrix revealed that false-negative U-Hb was associated with potentially high risk, false-negative U-Nit with intermediate risk, while false-negative U-Glc and U-Bil were associated with low risk on patient safety. Conclusions Positive ascorbic acid can cause potentially high risk for patient safety by missing positive blood in urine.
    Type of Medium: Online Resource
    ISSN: 0004-5632 , 1758-1001
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2020
    detail.hit.zdb_id: 2041298-8
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    In: Laboratory Medicine, Oxford University Press (OUP), Vol. 55, No. 2 ( 2024-03-07), p. 162-168
    Abstract: To investigate the association of immune response with vaccination adverse effects at peak anti–receptor-binding domain spike subunit 1 (anti-RBDS1) IgG after full vaccination with Comirnaty, Spikevax, or Vaxzevria. Methods Anti-RBDS1 IgG concentrations after vaccination were determined in healthy adults vaccinated with the Comirnaty, Spikevax, and Vaxzevria vaccines. The association of reactogenicity and peak antibody response after vaccination was tested. Results Anti-RBDS1 IgG values were significantly higher in the Comirnaty and Spikevax group, compared with the Vaxzevria group (P & lt; .001). Fever and muscle pain were found to be significant independent predictors of peak anti-RBDS1 IgG in the Comirnaty and Spikevax groups (P = .03 and P = .02, respectively). The multivariate model, adjusted for covariates, showed that no association between reactogenicity and peak antibody concentrations was found in the Comirnaty, Spikevax, and Vaxzevria groups. Conclusions No association between reactogenicity and peak anti-RBDS1 IgG after vaccination with the Comirnaty, Spikevax, and Vaxzevria vaccine was found.
    Type of Medium: Online Resource
    ISSN: 0007-5027 , 1943-7730
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2024
    detail.hit.zdb_id: 2100869-3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Croatian Society for Medical Biochemistry and Laboratory Medicine ; 2020
    In:  Biochemia medica Vol. 30, No. 2 ( 2020-06-15), p. 202-214
    In: Biochemia medica, Croatian Society for Medical Biochemistry and Laboratory Medicine, Vol. 30, No. 2 ( 2020-06-15), p. 202-214
    Abstract: Within the last several years, frequency of vitamin D testing has multiplied substantially all over the world, since it has been shown to have an important role in many diseases and conditions. Even though liquid chromatography - tandem mass spectrometry (LC-MS/MS) has been identified as “gold standard” method for vitamin D measurement, most laboratories still use immunochemistry methods. Besides analytical problems (hydrophobicity, low circulating concentrations, ability to bind to lipids, albumins and vitamin D binding protein, presence of multiple vitamin D metabolites and variable ratios of 25(OH)D2 and 25(OH)D3 in the blood), vitamin D shows great preanalytical variability, since its concentration is drastically influenced by seasonal changes, exposure to sun, type of clothes or sun block creams. Vitamin D is mostly measured in serum or plasma, but new studies are showing importance of measuring vitamin D in pleural effusions, breast milk, urine, synovial fluid and saliva. Besides the main role in calcium homeostasis and bone metabolism, many studies linked vitamin D deficiency with cancer, cardiovascular diseases, diabetes, fertility and many other conditions. However, even though initial observational studies indicated that supplementation with vitamin D might be beneficial in disease development and progression; first results of well-designed randomized controlled prospective studies did not find differences in frequency of cardiovascular events or invasive cancer between patients taking vitamin D supplementation compared to placebo. In the light of these recent findings, validity of excessive vitamin D testing remains an open question.
    Type of Medium: Online Resource
    ISSN: 1846-7482 , 1330-0962
    Language: Unknown
    Publisher: Croatian Society for Medical Biochemistry and Laboratory Medicine
    Publication Date: 2020
    detail.hit.zdb_id: 2280328-2
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    In: Clinical Chemistry and Laboratory Medicine (CCLM), Walter de Gruyter GmbH, Vol. 54, No. 3 ( 2016-01-1)
    Abstract: Endogenous interferences are an important source of biased laboratory results. Hemolysis, lipemia and icteria are the main source of endogenous interference in laboratory medicine. Accreditation according to ISO 15189 improves the overall quality of the laboratory procedures. The aim of our study was i) to assess the level of knowledge of Croatian medical biochemists about the proper detection and management of hemolysis, lipemia and icteria; and ii) to identify possible differences in the level of knowledge respective to the laboratory accreditation status. An on-line self-report survey was carried out by the Working Group for Preanalytical Phase of the Croatian Society of Medical Biochemistry and Laboratory Medicine during April to May 2015. Survey included 14 statements (Q1–Q14) about procedures for samples with interferences and participants were asked to assess the degree of agreement with the statement using a 4-point Likert scale. The lowest level of knowledge was observed for statements Q10 (dealing with icteric sample; 40.9% participants agreed with the correct procedure), Q12 (allowable error for interference; 47.2%) and Q11 (dealing with lipemic sample; 60.1%). Almost all participants (97.4%) agreed that laboratories in Croatia should have a harmonized protocol for management of samples with interferences. Participants from accredited laboratories showed higher knowledge of hemolysis detection (p=0.031), rejection of hemolyzed sample (p 〈 0.001), management of icteric samples (p=0.038) and allowable error for interferences (p=0.040). Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples. Accreditation is associated with higher knowledge about management of samples with interferences.
    Type of Medium: Online Resource
    ISSN: 1437-4331 , 1434-6621
    Language: Unknown
    Publisher: Walter de Gruyter GmbH
    Publication Date: 2016
    detail.hit.zdb_id: 1492732-9
    SSG: 15,3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Walter de Gruyter GmbH ; 2019
    In:  Clinical Chemistry and Laboratory Medicine (CCLM) Vol. 57, No. 12 ( 2019-11-26), p. 1882-1887
    In: Clinical Chemistry and Laboratory Medicine (CCLM), Walter de Gruyter GmbH, Vol. 57, No. 12 ( 2019-11-26), p. 1882-1887
    Abstract: Serum samples should be centrifuged for at least 10 min at 1300–2500 ×  g . Changed centrifugation conditions could compromise sample quality. The objective of this study was to compare the serum quality and turnaround time (TAT) using different centrifugation conditions. Methods The study was done in four different periods (A, B, C and D) at different conditions: for 10, 5 and 7 (A, B and C, respectively) at 2876 ×  g , and 7 (D) min at 4141 ×  g . Sample quality was assessed as the proportion of samples with: (a) aspiration errors, (b) H index 〉 0.5 g/L and (c) suppressed reports of potassium (K) due to hemolysis. TAT was calculated for emergency samples. The proportions of samples (a), (b) and (c) were compared according to period A. Results The number of aspiration errors was significantly higher in samples centrifuged at 2876 ×  g for 5 min (p = 0.021) and remained unchanged when centrifuged for 7 min (p = 0.066 and 0.177, for periods C and D, respectively). In periods B, C and D, the proportion of samples with hemolysis was higher than that in period A (p-values 0.039, 0.009 and 0.042, respectively). TAT differed between all periods (p  〈  0.001), with the lowest TAT observed for B and D. The lowest number of samples exceeding 60-min TAT was observed in period D (p = 0.011). Conclusions The integrity of serum samples is changed with different centrifugation conditions than those recommended. Our study showed that shorter centrifugation at higher force (7 min at 4141 ×  g ) significantly decreases TAT, with unchanged proportion of samples with aspiration errors.
    Type of Medium: Online Resource
    ISSN: 1437-4331 , 1434-6621
    Language: English
    Publisher: Walter de Gruyter GmbH
    Publication Date: 2019
    detail.hit.zdb_id: 1492732-9
    SSG: 15,3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Online Resource
    Online Resource
    MDPI AG ; 2021
    In:  Cancers Vol. 13, No. 18 ( 2021-09-19), p. 4696-
    In: Cancers, MDPI AG, Vol. 13, No. 18 ( 2021-09-19), p. 4696-
    Abstract: Prostate cancer (PC) is the most common malignancy in men. Common characteristic involved in PC pathogenesis are disturbed lipid metabolism and abnormal cholesterol accumulation. Cholesterol can be further utilized for membrane or hormone synthesis while cholesterol biosynthesis intermediates are important for oncogene membrane anchoring, nucleotide synthesis and mitochondrial electron transport. Since cholesterol and its biosynthesis intermediates influence numerous cellular processes, in this review we have described cholesterol homeostasis in a normal cell. Additionally, we have illustrated how commonly deregulated signaling pathways in PC (PI3K/AKT/MTOR, MAPK, AR and p53) are linked with cholesterol homeostasis regulation.
    Type of Medium: Online Resource
    ISSN: 2072-6694
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2527080-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Online Resource
    Online Resource
    Oxford University Press (OUP) ; 2016
    In:  Laboratory Medicine Vol. 47, No. 1 ( 2016-02), p. 39-42
    In: Laboratory Medicine, Oxford University Press (OUP), Vol. 47, No. 1 ( 2016-02), p. 39-42
    Type of Medium: Online Resource
    ISSN: 0007-5027 , 1943-7730
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2016
    detail.hit.zdb_id: 2100869-3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Online Resource
    Online Resource
    Walter de Gruyter GmbH ; 2022
    In:  Clinical Chemistry and Laboratory Medicine (CCLM) Vol. 60, No. 5 ( 2022-04-26), p. 714-725
    In: Clinical Chemistry and Laboratory Medicine (CCLM), Walter de Gruyter GmbH, Vol. 60, No. 5 ( 2022-04-26), p. 714-725
    Abstract: Hemolysis is associated with erroneous or delayed results. Objectives of the study were to compare four different methods for obtaining hemolysis in vitro on three different analyzers. Methods Hemolysis was prepared with addition of pure hemoglobin into serum pool, osmotic shock, aspiration through blood collection needle, freezing/thawing of whole blood. Biochemistry parameters were measured in duplicate at Architect c8000 (Abbott, Abbott Park, USA), Beckman Coulter AU680 (Beckman Coulter, Brea, USA) and Cobas 6000 c501 (Roche, Mannheim, Germany), according to manufacturers’ declarations. Cut-off value was defined as the highest value of H index with corresponding bias lower than acceptance criteria. Results We were not able to obtain results with freezing protocol. On all three platforms, lowest number of analytes were sensitive to hemolysis at H=0.5 using method of adding free hemoglobin. When osmotic shock was used, cut-off values for the most analytes were generally met at lower values. Hemolysis significantly interfered with measurement of potassium and lactate dehydrogenase (LD) at H=0.5 on all platforms. The most of the tested analytes had the lowest acceptable H index when aspiration method was used. At the low level of hemolysis (H=0.8) glucose, sodium, potassium, chloride, phosphate, and LD were affected on all analyzers, with some additional analytes depending on the manufacturer. Conclusions Hemolysis interference differs on different analyzers and according to protocol for obtaining hemolysis. Aspiration method was generally the most sensitive to hemolysis interference, while addition of free Hb was the most resistant.
    Type of Medium: Online Resource
    ISSN: 1434-6621 , 1437-4331
    Language: English
    Publisher: Walter de Gruyter GmbH
    Publication Date: 2022
    detail.hit.zdb_id: 1492732-9
    SSG: 15,3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    In: Bosnian Journal of Basic Medical Sciences, Association of Basic Medical Sciences of FBIH, ( 2022-08-26)
    Abstract: High prevalence and mortality of prostate cancer (PCa) are well known global health issues. Novel biomarkers for better identifying patients with PCa are the subject of extensive research. Prostate specific antigen (PSA) shows low specificity in screening and diagnostics, leading to unnecessary biopsies and health costs. Eighty patients with PCa and benign prostate hyperplasia (BPH) were included in the study. We analyzed CAV1 gene expression and methylation in tissue. CAV1 cfDNA methylation from blood and seminal plasma was accessed as a potential PCa biomarker. Although methylation in blood plasma did not differ between PCa and BPH patients, methylation in seminal plasma showed better PCa biomarker performances than tPSA (AUC 0.63 vs. AUC 0.52). Discrimination of BPH and Gleason grade group 1 PCa patients from patients with higher Gleason grade groups revealed very good performance as well (AUC 0.72). CAV1 methylation is useful biomarker with potential for further seminal plasma cfDNA research, but its diagnostic accuracy should be improved, as well as general knowledge about cfDNA in seminal plasma.
    Type of Medium: Online Resource
    ISSN: 1840-4812 , 1512-8601
    Language: Unknown
    Publisher: Association of Basic Medical Sciences of FBIH
    Publication Date: 2022
    detail.hit.zdb_id: 2548947-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    In: Cancers, MDPI AG, Vol. 14, No. 1 ( 2021-12-31), p. 189-
    Abstract: Seminoma (SE) is the most frequent type of testicular tumour, affecting predominantly young men. Early detection and diagnosis of SE could significantly improve life quality and reproductive health after diagnosis and treatment. Copy number variation (CNV) has already been associated with various cancers as well as SE. In this study, we selected four genes (MAGEC2, NANOG, RASSF1A, and KITLG) for CNV analysis in genomic DNA (gDNA), which are located on chromosomes susceptible to gains, and whose aberrant expression was already detected in SE. Furthermore, CNV was analysed in cell-free DNA (cfDNA) from seminal plasma. Analysis was performed by droplet digital polymerase chain reaction (ddPCR) on gDNA from SE and nonmalignant testicular tissue. Seminal plasma cfDNA from SE patients before and after surgery was analysed, as well as from healthy volunteers. The CNV hotspot in gDNA from SE tissue was detected for the first time in all analysed genes, and for two genes, NANOG and KITLG it was reflected in cfDNA from seminal plasma. Although clinical value is yet to be determined, presented data emphasize a potential use of CNV as a potential SE biomarker from a liquid biopsy.
    Type of Medium: Online Resource
    ISSN: 2072-6694
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2527080-1
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages