Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Ortopedia Traumatologia Rehabilitacja, Index Copernicus, Vol. 20, No. 2 ( 2018-4-30), p. 139-148
    Abstract: Background. Kinesiology Taping is a very popular physiotherapy method. It is used in both healthy people and orthopaedic patients in order to relieve pain, increase range of motion and for other purposes. Many researchers claim that these applications will also improve proprioception and sensorimotor efficiency, which are important for recovery after injuries and orthopaedic surgeries, especially on the knee joint. The aim of this study was to determine the effect of the muscle application of Kinesiology Taping on knee joint position sense in active motion. Material and methods. The study involved 50 healthy people (30 men and 20 women). Mean age was 23.2 years (range 18-30 years). The exclusion criteria were past knee injuries and knee surgery that could affect the test results. The participants were divided randomly into two equal groups. The first group (KT group) had a Kinesiology Taping muscle application placed, whereas a placebo application of an adhesive tape was used in the remaining participants (placebo group). Both applications were supposed to support quadriceps muscle activity. Joint position sense (JPS) was evaluated by measuring the error of active reproduction of the joint position (EARJP) of the knee in 45° flexion. The test was performed prior to applying the patch, after the patch was applied, then after 24 hours of wearing it and after removing the tape. The interval between trials before and after application of the patch was not less than 30 minutes. Statistical analysis was performed using Statistica 12.0. Distribution characteristics were calculated and the Wilcoxon test, Friedman‘s ANOVA and Mann-Whitney U test were performed. Results. The average test scores of JPS in the KT group and the placebo group before applying the KT patch were 3.48° and 5.16° respectively, compared to 4.84° and 4.88°, respectively, with the patch on, 5.12° and 4.96°, respectively, after 24 hours of wearing the tape, and 3.84° and 5.12°, respectively, after removing the patch. Within-group differences at any two time points were not statistically significant. There were also no significant differences between the groups. Conclusions. 1. Kinesiology Taping application to the quadriceps muscle had no significant effect on knee joint proprioception. Its use in order to improve sensorimotor skills therefore seems unreasonable. 2. The results are the basis for future prospective, randomised trials of larger experimental groups and involving the use of other Kinesiology Taping applications as well as including individuals with lesions of knee joint structures.
    Type of Medium: Online Resource
    ISSN: 1509-3492 , 2084-4336
    Language: English
    Publisher: Index Copernicus
    Publication Date: 2018
    detail.hit.zdb_id: 2629930-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    MDPI AG ; 2008
    In:  Pneumonologia i Alergologia Polska Vol. 72, No. 11-12 ( 2008-02-18), p. 482-486
    In: Pneumonologia i Alergologia Polska, MDPI AG, Vol. 72, No. 11-12 ( 2008-02-18), p. 482-486
    Type of Medium: Online Resource
    ISSN: 2299-8292 , 0867-7077
    Language: Unknown
    Publisher: MDPI AG
    Publication Date: 2008
    detail.hit.zdb_id: 2651949-5
    detail.hit.zdb_id: 2893877-X
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    MDPI AG ; 2019
    In:  Applied Sciences Vol. 9, No. 7 ( 2019-03-30), p. 1348-
    In: Applied Sciences, MDPI AG, Vol. 9, No. 7 ( 2019-03-30), p. 1348-
    Abstract: This research focused on a model setup fed with underground water pumped into a water supply network. The scope of the research included a long- and a short-term stagnation of water in the setup and a water flow of 0.1 m/s. The water supplied into the system gradually lost its corrosive properties and developed calcium carbonate precipitation capability. These processes indicated that cement components migrate from the lining into the water. Apart from the primary components, the presence of the following trace elements was found: iron (399.6 ppb), magnesium (17.8 ppm), zinc (26.9 ppb), barium (22.6 ppb), boron (21.6 ppb), sodium (10.8 ppm), gallium (2.1 ppb). At early stages of the operation, recorded quantities were not significant. Leaching of the trace elements from cement increased after water was chlorinated. In turn, the highest percent increases were observed in the case of zinc (217%), boron (19%) and gallium (12%), whereas the increase for sodium, iron, barium and magnesium in water was insignificant (reaching a few percent). A repeated analysis of samples of stagnant water in the setup showed that most of trace elements were below the detectability level. Final concentrations of all elements identified in the water after its contact with internal cement mortar lining were much lower than the limit values set out for drinking water.
    Type of Medium: Online Resource
    ISSN: 2076-3417
    Language: English
    Publisher: MDPI AG
    Publication Date: 2019
    detail.hit.zdb_id: 2704225-X
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages