    In: European Journal of Radiology, June 2013, Vol.82(6), pp.e281-e285
    Description: A high-pitch dual-source CT (DSCT) was compared to a standard single-source CT protocol in terms of dose and image quality for malignant lymphoma staging. Data from 43 patients who underwent DSCT (group 1) of the neck for staging of malignant lymphoma and 40 patients who underwent regular single source CT (group 2) were investigated retrospectively. Volume CT dose index (CTDIvol), dose length product (DLP), background noise (BN), attenuation values, signal-to-noise-ratio (SNR), scan time, effective tube current-time product (eff. mAs), subjective diagnostic image quality and artifact burden were compared. CTDIvol (5.5 ± 0.8 mGy vs. 12.4 ± 1.4 mGy), DLP (172 ± 27 mGycm vs. 344 ± 60 mGycm, 〈 0.0001), eff. mAs (98 ± 15 mAs vs. 183 ± 20 mAs, 〈 0.0001) and scan time (0.64 ± 0.05 s vs. 8.21 ± 0.72 s) were lower for group 1. BN was higher ( 〈 0.001) for group 1 with a mean difference of 2.6 HU. SNR for sternocleidomastoid and pectoral muscle was lower (6.6–12.3 vs. 7.8–19.1) for group 1. Subjective image quality (1.55 ± 0.6 vs. 1.42 ± 0.5) and artifact burden (1.62 ± 1.0 vs. 1.57 ± 0.9) were not rated significantly different ( = 0.47 and = 0.80) with a good inter-observer agreement ( = 0.59–0.90). High-pitch DSCT allows reduction of patient dose for cervical lymphoma staging while diagnostic image quality is preserved.
    Keywords: High-Pitch ; Dual Source ; Computed Tomography ; Cervical Lymph Node ; Lymphoma ; Medicine
    ISSN: 0720-048X
    E-ISSN: 1872-7727
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Language: English
    In: European Journal of Radiology, November 2015, Vol.84(11), pp.2052-2058
    Description: To evaluate a novel monoenergetic reconstruction algorithm (nMERA) with improved noise reduction for dual-energy CT (DECT) of pancreatic adenocarcinoma. Sixty patients with suspected pancreatic carcinoma underwent dual-source dual-energy CT with arterial phase. Images were reconstructed as linearly-blended 120-kV series (M_0.6) and with the standard monoenergetic (sMERA) and the novel monoenergetic algorithm (nMERA) with photon energies of 40, 55, 70 and 80 keV. Objective image quality was compared regarding image noise, pancreas attenuation, signal-to-noise ratio (SNR) and pancreas-to-lesion contrast. Subjective image quality was assessed by two observers. Thirty pancreatic adenocarcinomas were detected. nMERA showed significantly reduced image noise at low keV levels compared with sMERA images (55 keV: 7.19 ± 2.75 vs. 20.68 ± 7.01HU; 40 keV: 7.33 ± 3.20 vs. 37.22 ± 14.66HU) and M_0.6 (10.69 ± 3.57HU). nMERA pancreatic SNR was significantly superior to standard monoenergetic at 40 (47.02 ± 23.41 vs. 9.37 ± 5.83) and 55 keV (28.29 ± 16.86 vs. 9.88 ± 7.01), and M_0.6 series (11.42 ± 6.00). Pancreas-to-lesion contrast peaked in the nMERA 40 keV series (26.39 ± 16.83) and was significantly higher than in all other series ( 〈 0.001). nMERA 55 keV images series were consistently preferred by both observers over all other series ( 〈 0.01). nMERA DECT can significantly improve image quality and pancreas-to-lesion contrast in the diagnosis of pancreatic adenocarcinoma.
    Keywords: Dual-Energy CT ; Monoenergetic Reconstruction ; Pancreatic Adenocarcinoma ; Tumor Contrast ; Lesion Conspicuity ; Medicine