Kooperativer Bibliotheksverbund

Berlin Brandenburg

and
and

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Language: English
    In: Lasers in Surgery and Medicine, 2014, Vol.46(7), p.558(5)
    Description: To purchase or authenticate to the full-text of this article, please visit this link: http://onlinelibrary.wiley.com/doi/10.1002/lsm.22262/abstract Byline: Stefan Vallo, Katrin Eichler, Kathrin Kelly, Boris Schulz, Georg Bartsch, Axel Haferkamp, Thomas J Vogl, Stephan Zangos Purpose To evaluate the clinical value of different magnetic resonance imaging (MRI) sequences for a real-time thermo-monitoring during laser-induced thermotherapy (LITT) in kidneys. Methods Twenty-eight ex vivo pig kidneys were treated with laser ablation under MR guidance in a high-field MR scanner (Magnetom Espree or Avanto Fit, Siemens, Germany). For the thermal ablation of the kidney, a neodymium yttrium-aluminum-garnet (Nd:YAG) laser was used in combination with a special protective catheter (length 43cm, 4 French) which is sealed at the distal end. First, ablation was performed for 7, 10, and 13minutes using FLASH sequences for investigation of time-dependent growth of lesion size. In the second step, we evaluated the optimal imaging sequence during a 7minutes ablation of the kidney and after cooling using four different MR sequences (Haste, FLASH, radial VIBE, and Caipirinha DIXON). Results Macroscopic lesion volume increased from 3,784[+ or -]1,525mm.sub.3 to 7,683[+ or -]5,756mm.sub.3 after the ablation from 7 to 13minutes and MR volume ranged from 2,107[+ or -]1,674mm.sub.3 to 2,934[+ or -]1,549mm.sub.3 after the ablation from 7 to 13minutes. During ablation, FLASH (132[+ or -]34%) and radial VIBE (120[+ or -]43%) sequences displayed lesion volumes most efficiently with a trend to overestimation. The Caipirinha DIXON (323[+ or -]24%) sequence overestimated the volumes significantly during real-time monitoring. The volumes measured by MRI with FLASH (61[+ or -]30%), Haste (67[+ or -]28%), or radial VIBE (48[+ or -]14%) sequences after cooling of the kidney after ablation were always underestimated. The Caipirinha DIXON (142[+ or -]2%) sequence still overestimated the lesion volume after cooling of the kidney. Conclusion LITT is a feasible ablation modality in kidney tissue. Moreover, macroscopic and MR lesion volume increases time-dependently. For online monitoring, radial VIBE and FLASH sequences seem to be most efficient. Lasers Surg. Med. 46:558-562, 2014. [c] 2014 Wiley Periodicals, Inc. Article Note: Conflict of Interest Disclosures: All authors have completed and submitted the ICMJE Form for Disclosure of Potential Conflicts of Interest and none were reported.
    Keywords: Magnetic Alloys – Evaluation ; Magnetic Alloys – Comparative Analysis ; Rare Earth Metals – Evaluation ; Rare Earth Metals – Comparative Analysis ; Ablation (Surgery) – Comparative Analysis ; Rare Earth Metal Compounds – Evaluation ; Rare Earth Metal Compounds – Comparative Analysis ; Diagnostic Imaging – Comparative Analysis ; Lasers – Evaluation ; Lasers – Comparative Analysis
    ISSN: 0196-8092
    E-ISSN: 10969101
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Language: English
    In: The Journal of Urology, 2006, Vol.175(3), pp.1122-1126
    Description: We investigated a newly developed bipolar and multipolar RF ablation system with an internally cooled electrode and resistance controlled power output in a standardized model of perfused ex vivo kidney tissue. RF energy was applied at different power levels (20, 30 and 60 W) for 1, 3, 5 and 9 minutes. Each treatment parameter was repeated 5 times. For the 20/30 W levels a bipolar electrode with an active conducting part of 20/30 mm was selected. At 60 W 2 bipolar electrodes with an active conducting part (30 mm each) were connected. Lesion volumes and shapes were calculated by measuring the maximum vertical, long axis and short axis diameters of the macroscopic lesion. Lesion volume increased significantly with the treatment time and generator power applied (p 〈0.0001). Lesion size in multipolar ablated zones was larger than that in bipolar ablated zones. A reliable dose-effect relationship existed between the generator power/applied treatment time and ablated tissue lesion size. All lesions were elliptical. Bipolar and multipolar RF ablation with an internally cooled electrode and tissue resistance control represent an interesting advance in RF technology. The development of lesion size and volume is predictable, while a uniform lesion shape can be achieved in perfused ex vivo kidney tissue. Further in vivo trials are required to test whether complete and reliable tumor tissue ablation is possible with this system.
    Keywords: Kidney ; Surgical Procedures ; Minimally Invasive ; Carcinoma ; Renal Cell ; Catheter Ablation ; Swine ; Medicine
    ISSN: 0022-5347
    E-ISSN: 1527-3792
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Language: English
    In: Lasers in surgery and medicine, September 2014, Vol.46(7), pp.558-62
    Description: To evaluate the clinical value of different magnetic resonance imaging (MRI) sequences for a real-time thermo-monitoring during laser-induced thermotherapy (LITT) in kidneys. Twenty-eight ex vivo pig kidneys were treated with laser ablation under MR guidance in a high-field MR scanner (Magnetom Espree or Avanto Fit, Siemens, Germany). For the thermal ablation of the kidney, a neodymium yttrium-aluminum-garnet (Nd:YAG) laser was used in combination with a special protective catheter (length 43 cm, 4 French) which is sealed at the distal end. First, ablation was performed for 7, 10, and 13 minutes using FLASH sequences for investigation of time-dependent growth of lesion size. In the second step, we evaluated the optimal imaging sequence during a 7 minutes ablation of the kidney and after cooling using four different MR sequences (Haste, FLASH, radial VIBE, and Caipirinha DIXON). Macroscopic lesion volume increased from 3,784 ± 1,525 mm(3) to 7,683 ± 5,756 mm(3) after the ablation from 7 to 13 minutes and MR volume ranged from 2,107 ± 1,674 mm(3) to 2,934 ± 1,549 mm(3) after the ablation from 7 to 13 minutes. During ablation, FLASH (132 ± 34%) and radial VIBE (120 ± 43%) sequences displayed lesion volumes most efficiently with a trend to overestimation. The Caipirinha DIXON (323 ± 24%) sequence overestimated the volumes significantly during real-time monitoring. The volumes measured by MRI with FLASH (61 ± 30%), Haste (67 ± 28%), or radial VIBE (48 ± 14%) sequences after cooling of the kidney after ablation were always underestimated. The Caipirinha DIXON (142 ± 2%) sequence still overestimated the lesion volume after cooling of the kidney. LITT is a feasible ablation modality in kidney tissue. Moreover, macroscopic and MR lesion volume increases time-dependently. For online monitoring, radial VIBE and FLASH sequences seem to be most efficient.
    Keywords: Litt ; Mri ; Laser Ablation ; Real-Time Monitoring ; Renal Cancer ; Thermometry ; Surgery, Computer-Assisted ; Hyperthermia, Induced -- Methods ; Kidney -- Surgery ; Laser Therapy -- Methods ; Magnetic Resonance Imaging -- Methods
    E-ISSN: 1096-9101
    Source: MEDLINE/PubMed (U.S. National Library of Medicine)
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Language: English
    In: Scandinavian Journal of Urology, 04 July 2017, Vol.51(4), pp.342-344
    Keywords: Angiomyolipoma ; Flank Pain ; Kidney ; Selective Arterial Embolization ; Ureteral Stone ; Medicine
    ISSN: 2168-1805
    E-ISSN: 2168-1813
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Language: English
    In: European Urology, 2005, Vol.48(4), pp.584-592
    Description: Radiofrequency Ablation is an investigational treatment option for RCC. The aim of our study was to test the ablation algorithms of four different RF systems in a standardized ex vivo perfused porcine kidney model. A multitine monopolar dry electrode (impedance-based system), a multitine monopolar dry electrode (temperature-based system), a single monopolar wet electrode (impedance-based system) and a single monopolar dry, internally-cooled electrode (impedance-based system) were selected. RF energy was applied at different treatment parameters (power with and without control, tissue temperature, saline enhancement) for 1, 3, 5 and 9 minutes in healthy perfused ex vivo porcine tissue. Each treatment parameter was repeated 5 times. Maximum vertical, long-axis and short-axis diameters of the macroscopic lesion were measured and lesion volumes/ shapes were calculated. Lesion volumes increased significantly with the pre-selected tissue temperature and saline enhancement. Saline enhancement created larger, but irregular shaped lesions. The impedance-based system created lesion volumes that were predictable by treatment time and generator power. Lesions were unpredictable when uncontrolled generator power was applied. The created lesion shape was dependent on the selected electrode configuration. The currently available monopolar RFA systems offer different specific technical features to control tissue ablation. Detailed knowledge of the specific characteristics of each RF system is necessary to provide a higher chance of successful clinical outcome by complete and reliable ablation.
    Keywords: Radiofrequency (Rf) Ablation ; Kidney ; Renal Cell Carcinoma ; Experimental Study ; Medicine
    ISSN: 0302-2838
    E-ISSN: 1873-7560
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages