feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Frei verfügbar (Open Access)  (1)
Medientyp
Sprache
Region
Bibliothek
Erscheinungszeitraum
Zugriff
  • 1
    UID:
    edochu_18452_10254
    ISSN: 1437-4331 , 1437-4331
    Inhalt: Background: Fabry disease is an X-chromosomally inherited lysosomal storage disorder leading to accumulation of glycosphingolipids, mainly globotriaosylceramide (ceramide-trihexoside, Gb3). Concentrations of Gb3 in plasma and urine have been used to diagnose Fabry disease and to monitor enzyme replacement therapy with recombinant α-galactosidase. Methods: Gb3 was purified from plasma or urine by combined liquid extraction/protein precipitation and solid-phase extraction, and was detected by flow-injection analysis electrospray mass spectrometry (MS) using multi-reaction-monitoring. Calibration was performed via standard addition using C17-Gb3 as internal standard. The most abundant isoforms were monitored for calculation of total Gb3. Results: A MS-based assay for quantification of Gb3 in plasma and urine was established and validated. Intra- and inter-assay coefficient of variation (CV) of the method were ≤12%. However, at low concentrations the CV was 16%. The linear range covers roughly two orders of magnitude, down to 0.54 mg/L in plasma and 0.07 mg/L in urine. Careful adjustment of tuning parameters was necessary to obtain identical isoform intensities and quantitative results on different mass spectrometers. Gb3 concentrations in healthy controls were <4 mg/L in EDTA-plasma and <10 μg/mmol creatinine in urine. Significantly increased Gb3 concentrations were found in plasma and urine from male and female patients with Fabry disease. Conclusions: An improved MS protocol for Gb3 quantification has been developed, validated, and shown to be suitable for diagnosis and monitoring of Fabry patients. Clin Chem Lab Med 2010;48:189–98.
    Inhalt: Peer Reviewed
    In: Clinical Chemistry and Laboratory Medicine, : de Gruyter, 2010, 48,2009,2, Seiten 189-198, 1437-4331
    Sprache: Unbestimmte Sprache
    URL: Volltext  (kostenfrei)
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz