Kooperativer Bibliotheksverbund

Berlin Brandenburg

Your search history is empty.
and
and

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Water Resources Research, June 2017, Vol.53(6), pp.4709-4724
    Description: The relaxation dynamics toward a hydrostatic equilibrium after a change in phase saturation in porous media is governed by fluid reconfiguration at the pore scale. Little is known whether a hydrostatic equilibrium in which all interfaces come to rest is ever reached and which microscopic processes govern the time scales of relaxation. Here we apply fast synchrotron‐based X‐ray tomography (X‐ray CT) to measure the slow relaxation dynamics of fluid interfaces in a glass bead pack after fast drainage of the sample. The relaxation of interfaces triggers internal redistribution of fluids, reduces the surface energy stored in the fluid interfaces, and relaxes the contact angle toward the equilibrium value while the fluid topology remains unchanged. The equilibration of capillary pressures occurs in two stages: (i) a quick relaxation within seconds in which most of the pressure drop that built up during drainage is dissipated, a process that is to fast to be captured with fast X‐ray CT, and (ii) a slow relaxation with characteristic time scales of 1–4 h which manifests itself as a spontaneous imbibition process that is well described by the Washburn equation for capillary rise in porous media. The slow relaxation implies that a hydrostatic equilibrium is hardly ever attained in practice when conducting two‐phase experiments in which a flux boundary condition is changed from flow to no‐flow. Implications for experiments with pressure boundary conditions are discussed. What happens to fluids in a porous medium after pumping is stopped? Fast X‐ray tomography shows that even in a sample smaller than a sugar cube fluid interfaces continue to move for hours until an optimal fluid configuration is reached. The pace is limited by slow relaxation of dynamic contact angles. Therefore hydrostatic equilibrium, which is the state at which all fluid interfaces come to rest, is hardly ever attained in practice when conducting two‐phase flow experiments where the flow is stopped in much larger soil or rock samples. Relaxation dynamics through internal redistribution of fluids after fast drainage occurs in two stages A quick dissipation within seconds is followed by slow relaxation within several hours due to relaxation of dynamic contact angles Fluid configurations during relaxation are very different from those during quasi‐static drainage and imbibition
    Keywords: Two‐Phase Flow ; Dynamic Effects ; Hydraulic Nonequilibrium ; Dynamic Contact Angle ; Fluid Configuration ; Fluid Topology
    ISSN: 0043-1397
    E-ISSN: 1944-7973
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages