Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Type of Material
Type of Publication
Consortium
Language
1
UID:
(DE-627)1881658090
Format: 13 , Illustrationen
ISSN: 1532-2092
Content: Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings.Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index-guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator’s preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, and additional right atrial isthmus ablations. One hundred three patients (16%) underwent a redo procedure during follow-up documented comparable pulmonary vein (PV) reconnection among groups. Multivariate predictors of AF recurrence were age, left atrium (LA) size, persistent AF, and extra-PV ablation targets.High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions. Older age, larger LA size, persistent AF, and extra-PV ablation targets were identified in a multivariate analysis as independent risk factors for recurrences of atrial arrhythmias.
Note: 7. März 2023 , Gesehen am 27.02.2024
In: Europace, Oxford : Oxford Univ. Press, 1999, 25(2023), 4 vom: Apr., Seite 1379-1391, 1532-2092
In: volume:25
In: year:2023
In: number:4
In: month:04
In: pages:1379-1391
In: extent:13
Language: English
URL: Volltext  (kostenfrei)
URL: Volltext  (kostenfrei)
Library Location Call Number Volume/Issue/Year Availability
BibTip Others were also interested in ...
Associated Volumes
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages