Abstract
We show that adiabatic fast passage (AFP) pulses are robust refocusing elements of transverse 13C magnetization in multidimensional NMR experiments. A pair of identical AFP pulses can refocus selected parts or a complete 13 C chemical shift range in 13C spectra. In the constant time 13C-1H HSQC, replacement of attenuated rectangular pulses by selective AFP pulses results in a sensitivity enhancement of up to a factor of 1.8. In the 3D CBCA(CO)NH the signal-to-noise ratio is increased by a factor of up to 1.6.
Similar content being viewed by others
References
Abragam, A. (1961) Principles of Nuclear Magnetism, Clarendon Press, Oxford.
Abramovich, D.and Vega, S. (1993) J. Magn. Reson., A105, 30–48.
Baum, J., Tycko, R. and Pines, A. (1983) J. Chem. Phys.,79, 4643–4644.
Baur, M., Gemmecker, G. and Kessler, H. (1998) J. Magn. Reson., 132, 191–196.
Bax,A., Max, D. and Zax, D. (1992) J. Am. Chem. Soc., 114, 6923–6925.
Conolly, S., Clover, G., Nishimura, D. and Macovski, A. (1991) Magn. Reson. Med., 18, 28–38.
Freeman, R. (1987) A Handbook of Nuclear MagneticResonance, Wiley, New York, NY.
Fucini, P., Renner, C., Herberhold, C., Noegel, A.A. and Holak, T.A. (1997) Nat.Struct. Biol., 4, 223–230.
Grzesiek, S. and Bax, A. (1992) J. Am. Chem. Soc., 114, 6291–6293.
Hallenga, K. and Lippens, G.M. (1995) J. Biomol. NMR, 3, 59–66.
Hioe, F. (1984) Phys. Rev. A, 30,2100–2103.
Hwang, T.-L., van Zijl, P.C.M. and Garwood, M. (1998) J. Magn.Reson., 133, 200–203.
Kay, L.E., Xu, G.-Y., Singer, A.U., Muhandiram, D.R. and Forman-Kay, J.D. (1993) J. Magn. Reson., B101, 333–337.
Levitt, M.H. and Freeman, R. (1981) J. Magn. Reson., 43, 65–80.
Marion, D., Ikura, M., Tschudin, R. and Bax, A. (1989) J. Magn. Reson., 85, 393–399.
Muhandiram, D.R., Farrow, N.A., Xu, G.-Y., Smallcombe, S.H. and Kay, L.E. (1993) J. Magn. Reson., B102, 317–321.
Ogura, K., Terasawa, H. and Inagaki, F. (1996) J. Magn.Reson., B112, 63–68.
Ottinger, M., Delaglio, F., Marquardt, J.L., Tjandra, N. and Bax, A. (1998) J. Biomol. NMR,134, 365–369.
Rosenfeld, D., Panfil, S.L. and Zur, Y. (1997) J. Magn. Reson., 129, 115–124.
Shaka,A.J., Lee, C.J. and Pines, A. (1988) J. Magn. Reson., 77, 274–293.
Silver, M., Joseph, R. and Hoult, D. (1984) J.Magn. Reson., 59, 347–351.
U¢gurbil, K., Garwood, M., Rath, A.R. and Bendall, M.R. (1988) J. Magn. Reson.,78, 472–497.
Vuister, G.W. and Bax, A. (1992) J. Magn. Reson., 98, 428–435.
Vuister, G.W., Clore,G.M., Gronenborn, A.M., Powers, R., Garrett, D.S., Tschudin, R. and Bax, A. (1993) J. Magn. Reson., B101, 210–213.
Zweckstetter, M. and Holak, T.A. (1998) J. Magn. Reson., 133, 134–147.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Zweckstetter, M., Holak, T.A. Robust refocusing of 13C magnetization in multidimensional NMR experiments by adiabatic fast passage pulses. J Biomol NMR 15, 331–334 (1999). https://doi.org/10.1023/A:1008360013567
Issue Date:
DOI: https://doi.org/10.1023/A:1008360013567