Effect of Brazing Temperature and Clearance on Microstructure and Mechanical Properties of 316L Stainless Steel Brazed Joints

Article Preview

Abstract:

Vacuum brazing of 316L stainless steel with BNi-2 brazing filler metal.The effects of brazing temperature and brazing clearance on microstructure and mechanical properties of vacuum brazed joints of 316L stainless steel were studied. The results show that: As brazing temperature being 1 070 °C, with the increasing of the brazing clearance, the joint shear strength value become lower and lower. Brazing clearance compounds mainly contain intermetallic and solid solutions.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 418-420)

Pages:

1242-1245

Citation:

Online since:

December 2011

Export:

Price:

[1] Kun Shi, Zhishui Yu.Effect of Brazing Clearance on Microstructure and Hardness of Vacuum Brazing Joint of 316L Stainless Steel[J]. Materials of Mechanical Engineering. , 2010, 34(2):15. In Chinese.

Google Scholar

[2] Chaturvedi M C,OJo O A,Richards N L. Diffusion brazing of cast inconel 738 superalloy[J]. Advances in Technology of Materials and Materials Processing, 2004.6(2):206-213.

Google Scholar

[3] Zhishui Yu, Kun Shi, Ruifeng Li. Brazing Temperature influence on Ni-based alloy vacuum brazing joint hardness and organization [J]. Metal Casting and Welding Technology, 2009, 38, (17): 116-119. In Chinese.

Google Scholar