Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Purpose

The technique of pedicle screw stabilization is finding increasing popularity for use in the cervical spine. Implementing anterior transpedicular screws (ATPS) in cervical spine offers theoretical advantages compared to posterior stabilization. The goal of the current study was the development of a new setting for navigated insertion of ATPS, combining the advantage of reduced invasiveness of an anterior approach with the technical advantages of navigation.

Methods

20 screws were implanted in levels C3 to C6 of four cervical spine models (SAWBONES® Cervical Vertebrae with Anterior Ligament) with the use of 3D fluoroscopy navigation system [Arcadis Orbic 3D, Siemens and VectorVision fluoro 3D trauma software (BrainLAB)]. The accuracy of inserted screws was analyzed according to postoperative CT scans and following the modified Gertzbein and Robbins classification.

Results

20 anterior pedicle screws were placed in four human cervical spine models. Of these, eight screws were placed in C3, two screws in C4, six screws in C5, and four screws in C6. 16 of 20 screws (80 %) reached a grade 1 level of accuracy according to the modified Gertzbein and Robbins Classification. Three screws (15 %) were grade 2, and one screw (5 %) was grade 3. Grade 4 and 5 positions were not evident. Summing grades 1 and 2 together as “good” positions, 95 % of the screws achieved this level. Only a single screw did not fulfill these criteria.

Conclusion

The setting introduced in this study for navigated insertion of ATPS into cervical spine bone models is well implemented and shows excellent results, with an accuracy of 95 % (Gertzbein and Robbins grade 2 or better). Thus, this preliminary study represents a prelude to larger studies with larger case numbers on human specimens.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Barnes AH, Eguizabal JA, Acosta FL Jr, Lotz JC, Buckley JM, Ames CP (2009) Biomechanical pullout strength and stability of the cervical artificial pedicle screw. Spine (Phila Pa 1976) 34(1):E16–E20. doi:10.1097/BRS.0b013e3181891772

    Article  Google Scholar 

  2. Dunlap BJ, Karaikovic EE, Park HS, Sokolowski MJ, Zhang LQ (2010) Load sharing properties of cervical pedicle screw-rod constructs versus lateral mass screw-rod constructs. Eur Spine J 19(5):803–808. doi:10.1007/s00586-010-1278-0

    Article  PubMed  PubMed Central  Google Scholar 

  3. Tian W, Liu Y, Zheng S, Lv Y (2013) Accuracy of lower cervical pedicle screw placement with assistance of distinct navigation systems: a human cadaveric study. Eur Spine J 22(1):148–155. doi:10.1007/s00586-012-2494-6

    Article  PubMed  PubMed Central  Google Scholar 

  4. Xu R, Ebraheim NA, Skie M (2008) Pedicle screw fixation in the cervical spine. Am J Orthop (Belle Mead NJ) 37(8):403–408 (discussion 408)

    Google Scholar 

  5. Blauth M, Richter M, Lange U (1999) Trans-articular screw fixation of C1/C2 in atlanto-axial instability. Comparison between percutaneous and open procedures. Orthopade 28(8):651–661

    CAS  PubMed  Google Scholar 

  6. Haid RW Jr (2001) C1–C2 transarticular screw fixation: technical aspects. Neurosurgery 49(1):71–74

    PubMed  Google Scholar 

  7. Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ (2002) Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine (Phila Pa 1976) 27(16):1724–1732

    Article  Google Scholar 

  8. Kantelhardt SR, Keric N, Giese A (2012) Management of C2 fractures using Iso-C(3D) guidance: a single institution’s experience. Acta Neurochir (Wien) 154(10):1781–1787. doi:10.1007/s00701-012-1443-9

    Article  Google Scholar 

  9. Luther N, Iorgulescu JB, Geannette C, Gebhard H, Saleh T, Tsiouris AJ, Hartl R (2013) Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech. doi:10.1097/BSD.0b013e31828af33e

    Google Scholar 

  10. Nakashima H, Yukawa Y, Imagama S, Kanemura T, Kamiya M, Yanase M, Ito K, Machino M, Yoshida G, Ishikawa Y, Matsuyama Y, Ishiguro N, Kato F (2012) Complications of cervical pedicle screw fixation for nontraumatic lesions: a multicenter study of 84 patients. J Neurosurg Spine 16(3):238–247. doi:10.3171/2011.11.SPINE11102

    Article  PubMed  Google Scholar 

  11. Richter M, Cakir B, Schmidt R (2005) Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine (Phila Pa 1976) 30(20):2280–2287

    Article  Google Scholar 

  12. Richter M, Mattes T, Cakir B (2004) Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine. Eur Spine J 13(1):50–59. doi:10.1007/s00586-003-0604-1

    Article  PubMed  PubMed Central  Google Scholar 

  13. Zhang HL, Zhou DS, Jiang ZS (2011) Analysis of accuracy of computer-assisted navigation in cervical pedicle screw installation. Orthop Surg 3(1):52–56. doi:10.1111/j.1757-7861.2010.00110.x

    Article  CAS  PubMed  Google Scholar 

  14. Denis F (1983) The three column spine and its significance in the classification of acute thoracolumbar spinal injuries. Spine (Phila Pa 1976) 8(8):817–831

    Article  CAS  Google Scholar 

  15. Harel R, Hwang R, Fakhar M, Steinmetz MP, Novak E, Wang JC, Mroz TE (2013) Circumferential cervical surgery: to stage or not to stage? J Spinal Disord Tech 26(4):183–188. doi:10.1097/BSD.0b013e31823db361

    Article  PubMed  Google Scholar 

  16. Hartig D, Batke J, Dea N, Kelly A, Fisher C, Street J (2015) Adverse events in surgically treated cervical spondylopathic myelopathy: a prospective validated observational study. Spine (Phila Pa 1976) 40(5):292–298. doi:10.1097/BRS.0000000000000755

    Article  Google Scholar 

  17. Macagno A, Liu S, Marascalchi BJ, Yang S, Boniello AJ, Bendo JA, Lafage VC, Passias PG (2015) Perioperative risks associated with cervical spondylotic myelopathy based on surgical treatment strategies. Int J Spine Surg 9:24. doi:10.14444/2024

    PubMed  PubMed Central  Google Scholar 

  18. Mummaneni PV, Dhall SS, Rodts GE, Haid RW (2008) Circumferential fusion for cervical kyphotic deformity. J Neurosurg Spine 9(6):515–521. doi:10.3171/SPI.2008.10.08226

    Article  PubMed  Google Scholar 

  19. Koller H, Acosta F, Tauber M, Fox M, Martin H, Forstner R, Augat P, Penzkofer R, Pirich C, Kassmann H, Resch H, Hitzl W (2008) Cervical anterior transpedicular screw fixation (ATPS)—part II. Accuracy of manual insertion and pull-out strength of ATPS. Eur Spine J 17(4):539–555. doi:10.1007/s00586-007-0573-x

    Article  PubMed  PubMed Central  Google Scholar 

  20. Aramomi M, Masaki Y, Koshizuka S, Kadota R, Okawa A, Koda M, Yamazaki M (2008) Anterior pedicle screw fixation for multilevel cervical corpectomy and spinal fusion. Acta Neurochir (Wien) 150(6):575–582. doi:10.1007/s00701-008-1574-1 (discussion 582)

    Article  CAS  Google Scholar 

  21. Yukawa Y, Kato F, Ito K, Nakashima H, Machino M (2009) Anterior cervical pedicle screw and plate fixation using fluoroscope-assisted pedicle axis view imaging: a preliminary report of a new cervical reconstruction technique. Eur Spine J 18(6):911–916. doi:10.1007/s00586-009-0949-1

    Article  PubMed  PubMed Central  Google Scholar 

  22. Zhao LJ, Xu RM, Jiang WY, Ma WH, Xu NJ, Hu Y (2011) A new technique for anterior cervical pedicle screw implantation. Orthop Surg 3(3):193–198. doi:10.1111/j.1757-7861.2011.00145.x

    Article  PubMed  Google Scholar 

  23. Patton AG, Morris RP, Kuo YF, Lindsey RW (2015) Accuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws. Spine (Phila Pa 1976) 40(7):E404–E410. doi:10.1097/BRS.0000000000000786

    Article  Google Scholar 

  24. Caglar YS, Torun F, Pait TG, Hogue W, Bozkurt M, Ozgen S (2005) Biomechanical comparison of inside–outside screws, cables, and regular screws, using a sawbone model. Neurosurg Rev 28(1):53–58. doi:10.1007/s10143-004-0350-9

    PubMed  Google Scholar 

  25. Gottschalk MB, Yoon ST, Park DK, Rhee JM, Mitchell PM (2015) Surgical training using three-dimensional simulation in placement of cervical lateral mass screws: a blinded randomized control trial. Spine J 15(1):168–175. doi:10.1016/j.spinee.2014.08.444

    Article  PubMed  Google Scholar 

  26. Pal D, Bayley E, Magaji SA, Boszczyk BM (2011) Freehand determination of the trajectory angle for cervical lateral mass screws: how accurate is it? Eur Spine J 20(6):972–976. doi:10.1007/s00586-011-1694-9

    Article  PubMed  PubMed Central  Google Scholar 

  27. Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15(1):11–14

    Article  CAS  Google Scholar 

  28. Kotil K, Akcetin MA, Savas Y (2012) Neurovascular complications of cervical pedicle screw fixation. J Clin Neurosci 19(4):546–551. doi:10.1016/j.jocn.2011.05.041

    Article  PubMed  Google Scholar 

  29. Tomasino A, Parikh K, Koller H, Zink W, Tsiouris AJ, Steinberger J, Hartl R (2010) The vertebral artery and the cervical pedicle: morphometric analysis of a critical neighborhood. J Neurosurg Spine 13(1):52–60. doi:10.3171/2010.3.SPINE09231

    Article  PubMed  Google Scholar 

  30. Bredow J, Oppermann J, Kraus B, Schiller P, Schiffer G, Sobottke R, Eysel P, Koy T (2015) The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine. Eur Spine J. doi:10.1007/s00586-015-3974-2

    Google Scholar 

  31. Zhao L, Li G, Liu J, Benedict GM, Ebraheim NA, Ma W, Sun S, Xu R, Ruan C (2014) Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine. Eur Spine J 23(10):2175–2181. doi:10.1007/s00586-014-3473-x

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jan Bredow.

Ethics declarations

Conflict of interest

None.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bredow, J., Meyer, C., Scheyerer, M.J. et al. Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study. Eur Spine J 25, 1683–1689 (2016). https://doi.org/10.1007/s00586-016-4403-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-016-4403-x

Keywords

Navigation