Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Type of Medium
Language
Region
Library
Years
Keywords
  • 1
    UID:
    almafu_9960073799102883
    Format: 1 online resource (220 p.)
    Edition: First edition.
    ISBN: 9780081001325 , 0081001320 , 9780081001189 , 0081001185
    Series Statement: Woodhead Publishing Series in Energy ; Number 73
    Content: In March 2011 the Fukushima nuclear power plant (NPP) in Japan was hit by an earthquake and subsequent tsunami which resulted in the release of significant amounts of radioactive material. The incident led to the suspension of nuclear programmes by a number of countries. This book provides a definitive account of the accident. Outlines the main sequence of events of the 2011 Fukushima nuclear power plant accident, considers the responses of central and local government, and evaluates the response of the plant owner TEPCO.Describes and assesses the effectiveness of the evacuation process and s
    Note: Description based upon print version of record. , Front Cover; The 2011 Fukushima Nuclear Power Plant Accident: How and Why it Happened; Copyright; Contents; List of authors; Woodhead Publishing Series in Energy; Introduction; Chapter 1: The Fukushima-1 nuclear power plant accident; 1.1. Introduction; 1.2. Energy production in Japan; 1.2.1. The energy situation in Japan; 1.2.2. The Fukushima-1 accident: an unprecedented nuclear power accident; 1.3. The Fukushima-1 nuclear power plant; 1.3.1. TEPCO and nuclear power generation; 1.3.2. Overview of Fukushima-1 nuclear reactors; 1.3.3. Operation of the NPP; 1.3.4. Emergency operations , 1.4. The Tohoku Area Pacific Offshore Earthquake and tsunami1.4.1. The Tohoku Area Pacific Earthquake; 1.4.2. The Tohuku Area tsunami; 1.4.3. Status of the nuclear reactors before the earthquake; 1.4.4. Seismic movement at Fukushima-1 NPP; 1.4.5. The tsunami at Fukushima-1 NPP; 1.5. Nuclear power safety and disaster prevention systems in Japan; 1.5.1. Nuclear safety laws and regulations; 1.5.2. Administration of nuclear safety; 1.5.3. Organizations in charge of nuclear safety and regulation; 1.5.4. Overview of the legal system for nuclear disaster management , 1.5.5. Structure of the Nuclear Emergency Preparedness Act1.5.6. Nuclear Emergency Preparedness Act guidelines on emergency measures; 1.6. Conclusions; References; Chapter 2: The Fukushima nuclear power plant accident: the main sequence of events; 2.1. Introduction; 2.2. Outline of primary facilities at the Fukushima plant; 2.2.1. Reactor building facilities and components; Drywell (D/W); Suppression chamber (S/C); Safety relief valve (SRV); Vent valve; Diesel-driven fire pump (D/DFP); 2.2.2. Electrical power facilities; Metal-clad (M/C) switch gear; Power center (P/C); Direct current (D/C) , 2.2.3. Cooling systemsCore cooling systems during normal operation; Core cooling systems during normal shutdown (including after emergency shutdown [SCRAM]); Emergency cooling systems; Isolation condenser (IC); Reactor core isolation cooling system (RCIC); High-pressure coolant injection system (HPCI); Fire protection; 2.3. The sequence of events from earthquake and tsunami to station blackout (SBO); 2.3.1. Events immediately after the earthquake; March 11, 2011, about 14:46: magnitude 6-strong earthquake hits; March 11, about 14:50: Unit 2 RCIC started manually , March 11, 2011, 14:52: Unit 1 IC started automaticallyMarch 11, 15:05: Unit 3 RCIC started manually; March 11, about 15:27: first tsunami wave; March 11, about 15:35: second tsunami wave; March 11, about 15:39: Unit 2 RCIC started manually just before the tsunami damage; March 11, 15:37-42: loss of all AC power; 2.3.2. Loss of electrical power; 2.4. Possible damage caused by the earthquake; 2.4.1. Primary facilities in the reactor building; 2.4.2. Other facilities; 2.5. The condition of Unit 1 after SBO; 2.5.1. March 11, up to 23:50 when abnormal CV pressure was recognized , March 11, about 15:37: IC isolation valves closed with fail-safe function , English
    Additional Edition: ISBN 9781336008823
    Additional Edition: ISBN 1336008822
    Language: English
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    UID:
    almahu_9948320307202882
    Format: 1 online resource (220 pages) : , illustrations, maps, photographs, tables.
    ISBN: 9780081001325 (e-book)
    Series Statement: Woodhead Publishing Series in Energy ; Number 73
    Additional Edition: Print version: 2011 Fukushima nuclear power plant accident : how and why it happened. Cambridge, England : Elsevier ; Woodhead Publishing, c2015 ISBN 9780081001189
    Language: English
    Keywords: Electronic books.
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Did you mean 9780081001103?
Did you mean 9780071001182?
Did you mean 9780081000489?
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages