Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Online-Ressource
    Online-Ressource
    [Erscheinungsort nicht ermittelbar] : IWA Publishing
    UID:
    gbv_1778652557
    Umfang: 1 Online-Ressource
    ISBN: 9781780401171
    Inhalt: Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature for improved and more efficient operation of wastewater treatment plants. Unfortunately, their evaluation and comparison – either practical or based on simulation – is difficult. This is partly due to the variability of the influent, to the complexity of the biological and biochemical phenomena and to the large range of time constants (from a few minutes to several days). The lack of standard evaluation criteria is also a tremendous disadvantage. To really enhance the acceptance of innovative control strategies, such an evaluation needs to be based on a rigorous methodology including a simulation model, plant layout, controllers, sensors, performance criteria and test procedures, i.e. a complete benchmarking protocol. This book is a Scientific and Technical Report produced by the IWA Task Group on Benchmarking of Control Strategies for Wastewater Treatment Plants. The goal of the Task Group includes developing models and simulation tools that encompass the most typical unit processes within a wastewater treatment system (primary treatment, activated sludge, sludge treatment, etc.), as well as tools that will enable the evaluation of long-term control strategies and monitoring tasks (i.e. automatic detection of sensor and process faults). Work on these extensions has been carried out by the Task Group during the past five years, and the main results are summarized in Benchmarking of Control Strategies for Wastewater Treatment Plants. Besides a description of the final version of the already well-known Benchmark Simulation Model no. 1 (BSM1), the book includes the Benchmark Simulation Model no. 1 Long-Term (BSM1_LT) – with focus on benchmarking of process monitoring tasks – and the plant-wide Benchmark Simulation Model no. 2 (BSM2).
    Anmerkung: English
    Sprache: Englisch
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Online-Ressource
    Online-Ressource
    IWA Publishing | London, England :IWA Publishing,
    UID:
    almafu_9959748913502883
    Umfang: 1 online resource (120 p.)
    Ausgabe: 1st ed.
    ISBN: 1-78040-117-5
    Serie: Scientific and Technical Report ; Number 23
    Inhalt: Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature for improved and more efficient operation of wastewater treatment plants. Unfortunately, their evaluation and comparison - either practical or based on simulation - is difficult. This is partly due to the variability of the influent, to the complexity of the biological and biochemical phenomena and to the large range of time constants (from a few minutes to several days). The lack of standard evaluation criteria is also a tremendous disadvantage. To really enhance the acceptance of innovative control strategies, such an evaluation needs to be based on a rigorous methodology including a simulation model, plant layout, controllers, sensors, performance criteria and test procedures, i.e. a complete benchmarking protocol.  This book is a Scientific and Technical Report produced by the IWA Task Group on Benchmarking of Control Strategies for Wastewater Treatment Plants. The goal of the Task Group includes developing models and simulation tools that encompass the most typical unit processes within a wastewater treatment system (primary treatment, activated sludge, sludge treatment, etc.), as well as tools that will enable the evaluation of long-term control strategies and monitoring tasks (i.e. automatic detection of sensor and process faults). Work on these extensions has been carried out by the Task Group during the past five years, and the main results are summarized in Benchmarking of Control Strategies for Wastewater Treatment Plants. Besides a description of the final version of the already well-known Benchmark Simulation Model no. 1 (BSM1), the book includes the Benchmark Simulation Model no. 1 Long-Term (BSM1_LT) - with focus on benchmarking of process monitoring tasks - and the plant-wide Benchmark Simulation Model no. 2 (BSM2). 
    Anmerkung: Description based upon print version of record. , Cover -- Copyright -- Contents -- Nomenclature -- List of technical reports -- Preface -- Chapter 1: Introduction -- 1.1 What is Meant by a 'Benchmark Simulation Model'? -- 1.2 What is the Purpose of the Benchmark Simulation Models? -- 1.3 Who Should Use the Benchmark Simulation Models? -- 1.4 How Should the Benchmark Simulation Models be Used? -- 1.5 Who has been Involved in the Development of the Benchmark Simulation Models? -- 1.6 How Should this Scientific and Technical Report be Read? -- Chapter 2: Benchmark overview -- 2.1 Benchmark Simulation Model No. 1 -- 2.2 Benchmark Simulation Model No. 1 Long-Term -- 2.3 Benchmark Simulation Model No. 2 -- 2.4 The Benchmark Simulation Model Set -- Chapter 3: Benchmark plant description -- 3.1 Benchmark Simulation Model No. 1 -- 3.2 Benchmark Simulation Model No. 1 Long-Term -- 3.3 Benchmark Simulation Model No. 2 -- 3.4 Characteristics Summary -- Chapter 4: Benchmark models -- 4.1 Influent Modelling -- 4.1.1 BSM1 influent -- 4.1.2 BSM1_LT and BSM2 influent -- 4.2 Unit Process Models -- 4.2.1 Activated Sludge Model No. 1 (ASM1) -- 4.2.2 Anaerobic Digestion Model No. 1 (ADM1) -- 4.2.3 ASM/ADM interfacing -- 4.2.4 Solids separation models -- 4.2.5 Reject water storage tank -- 4.3 Sensors and Actuators -- 4.3.1 Sensors -- 4.3.2 Actuators -- 4.3.3 Faults and failures -- 4.4 Inhibition and Toxicity -- 4.4.1 Biological processes -- 4.4.2 Physical processes -- 4.4.3 Modelling inhibitory/toxic substances -- 4.5 Risk Assessment Modelling -- 4.5.1 Concept -- 4.5.2 Application to filamentous bulking -- 4.6 Temperature -- Chapter 5: Benchmarking of control strategies -- 5.1 BSM1 and BSM1_LT Controllers -- 5.1.1 Default BSM1 control strategy -- 5.1.2 Other BSM1 control handles -- 5.1.3 BSM1_LT control strategy -- 5.2 BSM2 Controllers -- 5.2.1 Default BSM2 control strategy. , 5.2.2 Testing other BSM2 control strategies -- Chapter 6: Evaluation criteria -- 6.1 Effluent and Influent Quality Indices -- 6.2 Effluent Concentrations -- 6.2.1 Ninety-five (95) percentiles -- 6.2.2 Number of violations -- 6.2.3 Percentage of time plant is in violation -- 6.3 Operational Cost Index -- 6.3.1 Aeration energy -- 6.3.2 Pumping energy -- 6.3.3 Sludge production for disposal -- 6.3.4 External carbon -- 6.3.5 Mixing energy -- 6.3.6 Methane production -- 6.3.7 Heating energy -- 6.4 Controller Assessment -- 6.4.1 Controlled variable tracking -- 6.4.2 Actuator performance -- 6.4.3 Risk-related evaluation criteria -- 6.5 Monitoring Performance Assessment -- 6.6 Evaluation Summary -- Chapter 7: Simulation procedure -- 7.1 BSM1 -- 7.2 BSM1_LT -- 7.3 BSM2 -- Chapter 8: Ring-testing -- 8.1 Steady State Verification -- 8.2 Dynamic Verification -- 8.3 Findings -- Chapter 9: BSM limitations -- 9.1 BSM as a Toolbox -- 9.2 Model Structures -- 9.2.1 Biokinetic models -- 9.2.2 Aeration -- 9.2.3 Solid/Liquid separation models -- 9.2.4 Other models -- 9.3 Model Parameters -- 9.4 Evaluation Criteria -- 9.5 Model Simulation -- 9.6 Application Extension -- 9.7 Conclusion -- Chapter 10: Conclusions and perspectives -- 10.1 Lessons Learned: Development of the Benchmark Platforms -- 10.2 Lessons Learned: Use of the Benchmark Platforms, Verified Process Models and Generic Tools -- 10.2.1 Portability -- 10.2.2 Extensions -- 10.3 Looking Ahead: Future Extensions of the BSM Platforms -- 10.3.1 Temporal extensions -- 10.3.2 Spatial extensions -- 10.3.3 Process extensions -- 10.3.4 Realism of models used in BSM -- 10.3.5 Control strategy extensions -- 10.3.6 Extended evaluation tools -- 10.4 The 'Benchmarking Spirit' -- References -- Appendix A: Model parameters -- Appendix B: Simulation output -- Index. , English
    Weitere Ausg.: ISBN 1-84339-146-5
    Sprache: Englisch
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Online-Ressource
    Online-Ressource
    London, England :IWA Publishing,
    UID:
    almahu_9948321971602882
    Umfang: 1 online resource (166 pages) : , illustrations.
    ISBN: 9781780401171 (e-book)
    Serie: Scientific and Technical Report ; Number 23
    Weitere Ausg.: Print version: Benchmarking of control strategies for wastewater treatment plants : London, England : IWA Publishing, c2014 ISBN 9781843391463
    Sprache: Englisch
    Fachgebiete: Technik , Allgemeines
    RVK:
    RVK:
    RVK:
    Schlagwort(e): Electronic books. ; Electronic books.
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    UID:
    almahu_9949550237602882
    Umfang: 1 online resource (1 p.)
    ISBN: 9781780401171
    Serie: Scientific and Technical Report Series
    Inhalt: Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature for improved and more efficient operation of wastewater treatment plants. Unfortunately, their evaluation and comparison - either practical or based on simulation - is difficult. This is partly due to the variability of the influent, to the complexity of the biological and biochemical phenomena and to the large range of time constants (from a few minutes to several days). The lack of standard evaluation criteria is also a tremendous disadvantage. To really enhance the acceptance of innovative control strategies, such an evaluation needs to be based on a rigorous methodology including a simulation model, plant layout, controllers, sensors, performance criteria and test procedures, i.e. a complete benchmarking protocol.  This book is a Scientific and Technical Report produced by the IWA Task Group on Benchmarking of Control Strategies for Wastewater Treatment Plants. The goal of the Task Group includes developing models and simulation tools that encompass the most typical unit processes within a wastewater treatment system (primary treatment, activated sludge, sludge treatment, etc.), as well as tools that will enable the evaluation of long-term control strategies and monitoring tasks (i.e. automatic detection of sensor and process faults). Work on these extensions has been carried out by the Task Group during the past five years, and the main results are summarized in Benchmarking of Control Strategies for Wastewater Treatment Plants. Besides a description of the final version of the already well-known Benchmark Simulation Model no. 1 (BSM1), the book includes the Benchmark Simulation Model no. 1 Long-Term (BSM1_LT) - with focus on benchmarking of process monitoring tasks - and the plant-wide Benchmark Simulation Model no. 2 (BSM2). 
    Sprache: Englisch
    Schlagwort(e): Electronic books.
    URL: Image  (Thumbnail cover image)
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    UID:
    gbv_1657967832
    Umfang: 1 online resource (120 pages)
    ISBN: 9781780401171
    Serie: Scientific and Technical Report Series
    Inhalt: Cover -- Copyright -- Contents -- Nomenclature -- List of technical reports -- Preface -- Chapter 1: Introduction -- 1.1 What is Meant by a 'Benchmark Simulation Model'? -- 1.2 What is the Purpose of the Benchmark Simulation Models? -- 1.3 Who Should Use the Benchmark Simulation Models? -- 1.4 How Should the Benchmark Simulation Models be Used? -- 1.5 Who has been Involved in the Development of the Benchmark Simulation Models? -- 1.6 How Should this Scientific and Technical Report be Read? -- Chapter 2: Benchmark overview -- 2.1 Benchmark Simulation Model No. 1 -- 2.2 Benchmark Simulation Model No. 1 Long-Term -- 2.3 Benchmark Simulation Model No. 2 -- 2.4 The Benchmark Simulation Model Set -- Chapter 3: Benchmark plant description -- 3.1 Benchmark Simulation Model No. 1 -- 3.2 Benchmark Simulation Model No. 1 Long-Term -- 3.3 Benchmark Simulation Model No. 2 -- 3.4 Characteristics Summary -- Chapter 4: Benchmark models -- 4.1 Influent Modelling -- 4.1.1 BSM1 influent -- 4.1.2 BSM1_LT and BSM2 influent -- 4.2 Unit Process Models -- 4.2.1 Activated Sludge Model No. 1 (ASM1) -- 4.2.2 Anaerobic Digestion Model No. 1 (ADM1) -- 4.2.3 ASM/ADM interfacing -- 4.2.4 Solids separation models -- 4.2.5 Reject water storage tank -- 4.3 Sensors and Actuators -- 4.3.1 Sensors -- 4.3.2 Actuators -- 4.3.3 Faults and failures -- 4.4 Inhibition and Toxicity -- 4.4.1 Biological processes -- 4.4.2 Physical processes -- 4.4.3 Modelling inhibitory/toxic substances -- 4.5 Risk Assessment Modelling -- 4.5.1 Concept -- 4.5.2 Application to filamentous bulking -- 4.6 Temperature -- Chapter 5: Benchmarking of control strategies -- 5.1 BSM1 and BSM1_LT Controllers -- 5.1.1 Default BSM1 control strategy -- 5.1.2 Other BSM1 control handles -- 5.1.3 BSM1_LT control strategy -- 5.2 BSM2 Controllers -- 5.2.1 Default BSM2 control strategy.
    Anmerkung: Description based on publisher supplied metadata and other sources
    Weitere Ausg.: ISBN 9781843391463
    Weitere Ausg.: Erscheint auch als Druck-Ausgabe Benchmarking of control strategies for wastewater treatment plants London : IWA Publ., 2014 ISBN 9781843391463
    Sprache: Englisch
    Fachgebiete: Allgemeines
    RVK:
    RVK:
    URL: Volltext  (lizenzpflichtig)
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Online-Ressource
    Online-Ressource
    IWA Publishing | London, England :IWA Publishing,
    UID:
    almahu_9948641603702882
    Umfang: 1 online resource (120 p.)
    Ausgabe: 1st ed.
    ISBN: 1-78040-117-5
    Serie: Scientific and Technical Report ; Number 23
    Inhalt: Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature for improved and more efficient operation of wastewater treatment plants. Unfortunately, their evaluation and comparison - either practical or based on simulation - is difficult. This is partly due to the variability of the influent, to the complexity of the biological and biochemical phenomena and to the large range of time constants (from a few minutes to several days). The lack of standard evaluation criteria is also a tremendous disadvantage. To really enhance the acceptance of innovative control strategies, such an evaluation needs to be based on a rigorous methodology including a simulation model, plant layout, controllers, sensors, performance criteria and test procedures, i.e. a complete benchmarking protocol.  This book is a Scientific and Technical Report produced by the IWA Task Group on Benchmarking of Control Strategies for Wastewater Treatment Plants. The goal of the Task Group includes developing models and simulation tools that encompass the most typical unit processes within a wastewater treatment system (primary treatment, activated sludge, sludge treatment, etc.), as well as tools that will enable the evaluation of long-term control strategies and monitoring tasks (i.e. automatic detection of sensor and process faults). Work on these extensions has been carried out by the Task Group during the past five years, and the main results are summarized in Benchmarking of Control Strategies for Wastewater Treatment Plants. Besides a description of the final version of the already well-known Benchmark Simulation Model no. 1 (BSM1), the book includes the Benchmark Simulation Model no. 1 Long-Term (BSM1_LT) - with focus on benchmarking of process monitoring tasks - and the plant-wide Benchmark Simulation Model no. 2 (BSM2). 
    Anmerkung: Description based upon print version of record. , Cover -- Copyright -- Contents -- Nomenclature -- List of technical reports -- Preface -- Chapter 1: Introduction -- 1.1 What is Meant by a 'Benchmark Simulation Model'? -- 1.2 What is the Purpose of the Benchmark Simulation Models? -- 1.3 Who Should Use the Benchmark Simulation Models? -- 1.4 How Should the Benchmark Simulation Models be Used? -- 1.5 Who has been Involved in the Development of the Benchmark Simulation Models? -- 1.6 How Should this Scientific and Technical Report be Read? -- Chapter 2: Benchmark overview -- 2.1 Benchmark Simulation Model No. 1 -- 2.2 Benchmark Simulation Model No. 1 Long-Term -- 2.3 Benchmark Simulation Model No. 2 -- 2.4 The Benchmark Simulation Model Set -- Chapter 3: Benchmark plant description -- 3.1 Benchmark Simulation Model No. 1 -- 3.2 Benchmark Simulation Model No. 1 Long-Term -- 3.3 Benchmark Simulation Model No. 2 -- 3.4 Characteristics Summary -- Chapter 4: Benchmark models -- 4.1 Influent Modelling -- 4.1.1 BSM1 influent -- 4.1.2 BSM1_LT and BSM2 influent -- 4.2 Unit Process Models -- 4.2.1 Activated Sludge Model No. 1 (ASM1) -- 4.2.2 Anaerobic Digestion Model No. 1 (ADM1) -- 4.2.3 ASM/ADM interfacing -- 4.2.4 Solids separation models -- 4.2.5 Reject water storage tank -- 4.3 Sensors and Actuators -- 4.3.1 Sensors -- 4.3.2 Actuators -- 4.3.3 Faults and failures -- 4.4 Inhibition and Toxicity -- 4.4.1 Biological processes -- 4.4.2 Physical processes -- 4.4.3 Modelling inhibitory/toxic substances -- 4.5 Risk Assessment Modelling -- 4.5.1 Concept -- 4.5.2 Application to filamentous bulking -- 4.6 Temperature -- Chapter 5: Benchmarking of control strategies -- 5.1 BSM1 and BSM1_LT Controllers -- 5.1.1 Default BSM1 control strategy -- 5.1.2 Other BSM1 control handles -- 5.1.3 BSM1_LT control strategy -- 5.2 BSM2 Controllers -- 5.2.1 Default BSM2 control strategy. , 5.2.2 Testing other BSM2 control strategies -- Chapter 6: Evaluation criteria -- 6.1 Effluent and Influent Quality Indices -- 6.2 Effluent Concentrations -- 6.2.1 Ninety-five (95) percentiles -- 6.2.2 Number of violations -- 6.2.3 Percentage of time plant is in violation -- 6.3 Operational Cost Index -- 6.3.1 Aeration energy -- 6.3.2 Pumping energy -- 6.3.3 Sludge production for disposal -- 6.3.4 External carbon -- 6.3.5 Mixing energy -- 6.3.6 Methane production -- 6.3.7 Heating energy -- 6.4 Controller Assessment -- 6.4.1 Controlled variable tracking -- 6.4.2 Actuator performance -- 6.4.3 Risk-related evaluation criteria -- 6.5 Monitoring Performance Assessment -- 6.6 Evaluation Summary -- Chapter 7: Simulation procedure -- 7.1 BSM1 -- 7.2 BSM1_LT -- 7.3 BSM2 -- Chapter 8: Ring-testing -- 8.1 Steady State Verification -- 8.2 Dynamic Verification -- 8.3 Findings -- Chapter 9: BSM limitations -- 9.1 BSM as a Toolbox -- 9.2 Model Structures -- 9.2.1 Biokinetic models -- 9.2.2 Aeration -- 9.2.3 Solid/Liquid separation models -- 9.2.4 Other models -- 9.3 Model Parameters -- 9.4 Evaluation Criteria -- 9.5 Model Simulation -- 9.6 Application Extension -- 9.7 Conclusion -- Chapter 10: Conclusions and perspectives -- 10.1 Lessons Learned: Development of the Benchmark Platforms -- 10.2 Lessons Learned: Use of the Benchmark Platforms, Verified Process Models and Generic Tools -- 10.2.1 Portability -- 10.2.2 Extensions -- 10.3 Looking Ahead: Future Extensions of the BSM Platforms -- 10.3.1 Temporal extensions -- 10.3.2 Spatial extensions -- 10.3.3 Process extensions -- 10.3.4 Realism of models used in BSM -- 10.3.5 Control strategy extensions -- 10.3.6 Extended evaluation tools -- 10.4 The 'Benchmarking Spirit' -- References -- Appendix A: Model parameters -- Appendix B: Simulation output -- Index. , English
    Weitere Ausg.: ISBN 1-84339-146-5
    Sprache: Englisch
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Online-Ressource
    Online-Ressource
    IWA Publishing | London, England :IWA Publishing,
    UID:
    edoccha_9959748913502883
    Umfang: 1 online resource (120 p.)
    Ausgabe: 1st ed.
    ISBN: 1-78040-117-5
    Serie: Scientific and Technical Report ; Number 23
    Inhalt: Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature for improved and more efficient operation of wastewater treatment plants. Unfortunately, their evaluation and comparison - either practical or based on simulation - is difficult. This is partly due to the variability of the influent, to the complexity of the biological and biochemical phenomena and to the large range of time constants (from a few minutes to several days). The lack of standard evaluation criteria is also a tremendous disadvantage. To really enhance the acceptance of innovative control strategies, such an evaluation needs to be based on a rigorous methodology including a simulation model, plant layout, controllers, sensors, performance criteria and test procedures, i.e. a complete benchmarking protocol.  This book is a Scientific and Technical Report produced by the IWA Task Group on Benchmarking of Control Strategies for Wastewater Treatment Plants. The goal of the Task Group includes developing models and simulation tools that encompass the most typical unit processes within a wastewater treatment system (primary treatment, activated sludge, sludge treatment, etc.), as well as tools that will enable the evaluation of long-term control strategies and monitoring tasks (i.e. automatic detection of sensor and process faults). Work on these extensions has been carried out by the Task Group during the past five years, and the main results are summarized in Benchmarking of Control Strategies for Wastewater Treatment Plants. Besides a description of the final version of the already well-known Benchmark Simulation Model no. 1 (BSM1), the book includes the Benchmark Simulation Model no. 1 Long-Term (BSM1_LT) - with focus on benchmarking of process monitoring tasks - and the plant-wide Benchmark Simulation Model no. 2 (BSM2). 
    Anmerkung: Description based upon print version of record. , Cover -- Copyright -- Contents -- Nomenclature -- List of technical reports -- Preface -- Chapter 1: Introduction -- 1.1 What is Meant by a 'Benchmark Simulation Model'? -- 1.2 What is the Purpose of the Benchmark Simulation Models? -- 1.3 Who Should Use the Benchmark Simulation Models? -- 1.4 How Should the Benchmark Simulation Models be Used? -- 1.5 Who has been Involved in the Development of the Benchmark Simulation Models? -- 1.6 How Should this Scientific and Technical Report be Read? -- Chapter 2: Benchmark overview -- 2.1 Benchmark Simulation Model No. 1 -- 2.2 Benchmark Simulation Model No. 1 Long-Term -- 2.3 Benchmark Simulation Model No. 2 -- 2.4 The Benchmark Simulation Model Set -- Chapter 3: Benchmark plant description -- 3.1 Benchmark Simulation Model No. 1 -- 3.2 Benchmark Simulation Model No. 1 Long-Term -- 3.3 Benchmark Simulation Model No. 2 -- 3.4 Characteristics Summary -- Chapter 4: Benchmark models -- 4.1 Influent Modelling -- 4.1.1 BSM1 influent -- 4.1.2 BSM1_LT and BSM2 influent -- 4.2 Unit Process Models -- 4.2.1 Activated Sludge Model No. 1 (ASM1) -- 4.2.2 Anaerobic Digestion Model No. 1 (ADM1) -- 4.2.3 ASM/ADM interfacing -- 4.2.4 Solids separation models -- 4.2.5 Reject water storage tank -- 4.3 Sensors and Actuators -- 4.3.1 Sensors -- 4.3.2 Actuators -- 4.3.3 Faults and failures -- 4.4 Inhibition and Toxicity -- 4.4.1 Biological processes -- 4.4.2 Physical processes -- 4.4.3 Modelling inhibitory/toxic substances -- 4.5 Risk Assessment Modelling -- 4.5.1 Concept -- 4.5.2 Application to filamentous bulking -- 4.6 Temperature -- Chapter 5: Benchmarking of control strategies -- 5.1 BSM1 and BSM1_LT Controllers -- 5.1.1 Default BSM1 control strategy -- 5.1.2 Other BSM1 control handles -- 5.1.3 BSM1_LT control strategy -- 5.2 BSM2 Controllers -- 5.2.1 Default BSM2 control strategy. , 5.2.2 Testing other BSM2 control strategies -- Chapter 6: Evaluation criteria -- 6.1 Effluent and Influent Quality Indices -- 6.2 Effluent Concentrations -- 6.2.1 Ninety-five (95) percentiles -- 6.2.2 Number of violations -- 6.2.3 Percentage of time plant is in violation -- 6.3 Operational Cost Index -- 6.3.1 Aeration energy -- 6.3.2 Pumping energy -- 6.3.3 Sludge production for disposal -- 6.3.4 External carbon -- 6.3.5 Mixing energy -- 6.3.6 Methane production -- 6.3.7 Heating energy -- 6.4 Controller Assessment -- 6.4.1 Controlled variable tracking -- 6.4.2 Actuator performance -- 6.4.3 Risk-related evaluation criteria -- 6.5 Monitoring Performance Assessment -- 6.6 Evaluation Summary -- Chapter 7: Simulation procedure -- 7.1 BSM1 -- 7.2 BSM1_LT -- 7.3 BSM2 -- Chapter 8: Ring-testing -- 8.1 Steady State Verification -- 8.2 Dynamic Verification -- 8.3 Findings -- Chapter 9: BSM limitations -- 9.1 BSM as a Toolbox -- 9.2 Model Structures -- 9.2.1 Biokinetic models -- 9.2.2 Aeration -- 9.2.3 Solid/Liquid separation models -- 9.2.4 Other models -- 9.3 Model Parameters -- 9.4 Evaluation Criteria -- 9.5 Model Simulation -- 9.6 Application Extension -- 9.7 Conclusion -- Chapter 10: Conclusions and perspectives -- 10.1 Lessons Learned: Development of the Benchmark Platforms -- 10.2 Lessons Learned: Use of the Benchmark Platforms, Verified Process Models and Generic Tools -- 10.2.1 Portability -- 10.2.2 Extensions -- 10.3 Looking Ahead: Future Extensions of the BSM Platforms -- 10.3.1 Temporal extensions -- 10.3.2 Spatial extensions -- 10.3.3 Process extensions -- 10.3.4 Realism of models used in BSM -- 10.3.5 Control strategy extensions -- 10.3.6 Extended evaluation tools -- 10.4 The 'Benchmarking Spirit' -- References -- Appendix A: Model parameters -- Appendix B: Simulation output -- Index. , English
    Weitere Ausg.: ISBN 1-84339-146-5
    Sprache: Englisch
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Online-Ressource
    Online-Ressource
    IWA Publishing | London, England :IWA Publishing,
    UID:
    edocfu_9959748913502883
    Umfang: 1 online resource (120 p.)
    Ausgabe: 1st ed.
    ISBN: 1-78040-117-5
    Serie: Scientific and Technical Report ; Number 23
    Inhalt: Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature for improved and more efficient operation of wastewater treatment plants. Unfortunately, their evaluation and comparison - either practical or based on simulation - is difficult. This is partly due to the variability of the influent, to the complexity of the biological and biochemical phenomena and to the large range of time constants (from a few minutes to several days). The lack of standard evaluation criteria is also a tremendous disadvantage. To really enhance the acceptance of innovative control strategies, such an evaluation needs to be based on a rigorous methodology including a simulation model, plant layout, controllers, sensors, performance criteria and test procedures, i.e. a complete benchmarking protocol.  This book is a Scientific and Technical Report produced by the IWA Task Group on Benchmarking of Control Strategies for Wastewater Treatment Plants. The goal of the Task Group includes developing models and simulation tools that encompass the most typical unit processes within a wastewater treatment system (primary treatment, activated sludge, sludge treatment, etc.), as well as tools that will enable the evaluation of long-term control strategies and monitoring tasks (i.e. automatic detection of sensor and process faults). Work on these extensions has been carried out by the Task Group during the past five years, and the main results are summarized in Benchmarking of Control Strategies for Wastewater Treatment Plants. Besides a description of the final version of the already well-known Benchmark Simulation Model no. 1 (BSM1), the book includes the Benchmark Simulation Model no. 1 Long-Term (BSM1_LT) - with focus on benchmarking of process monitoring tasks - and the plant-wide Benchmark Simulation Model no. 2 (BSM2). 
    Anmerkung: Description based upon print version of record. , Cover -- Copyright -- Contents -- Nomenclature -- List of technical reports -- Preface -- Chapter 1: Introduction -- 1.1 What is Meant by a 'Benchmark Simulation Model'? -- 1.2 What is the Purpose of the Benchmark Simulation Models? -- 1.3 Who Should Use the Benchmark Simulation Models? -- 1.4 How Should the Benchmark Simulation Models be Used? -- 1.5 Who has been Involved in the Development of the Benchmark Simulation Models? -- 1.6 How Should this Scientific and Technical Report be Read? -- Chapter 2: Benchmark overview -- 2.1 Benchmark Simulation Model No. 1 -- 2.2 Benchmark Simulation Model No. 1 Long-Term -- 2.3 Benchmark Simulation Model No. 2 -- 2.4 The Benchmark Simulation Model Set -- Chapter 3: Benchmark plant description -- 3.1 Benchmark Simulation Model No. 1 -- 3.2 Benchmark Simulation Model No. 1 Long-Term -- 3.3 Benchmark Simulation Model No. 2 -- 3.4 Characteristics Summary -- Chapter 4: Benchmark models -- 4.1 Influent Modelling -- 4.1.1 BSM1 influent -- 4.1.2 BSM1_LT and BSM2 influent -- 4.2 Unit Process Models -- 4.2.1 Activated Sludge Model No. 1 (ASM1) -- 4.2.2 Anaerobic Digestion Model No. 1 (ADM1) -- 4.2.3 ASM/ADM interfacing -- 4.2.4 Solids separation models -- 4.2.5 Reject water storage tank -- 4.3 Sensors and Actuators -- 4.3.1 Sensors -- 4.3.2 Actuators -- 4.3.3 Faults and failures -- 4.4 Inhibition and Toxicity -- 4.4.1 Biological processes -- 4.4.2 Physical processes -- 4.4.3 Modelling inhibitory/toxic substances -- 4.5 Risk Assessment Modelling -- 4.5.1 Concept -- 4.5.2 Application to filamentous bulking -- 4.6 Temperature -- Chapter 5: Benchmarking of control strategies -- 5.1 BSM1 and BSM1_LT Controllers -- 5.1.1 Default BSM1 control strategy -- 5.1.2 Other BSM1 control handles -- 5.1.3 BSM1_LT control strategy -- 5.2 BSM2 Controllers -- 5.2.1 Default BSM2 control strategy. , 5.2.2 Testing other BSM2 control strategies -- Chapter 6: Evaluation criteria -- 6.1 Effluent and Influent Quality Indices -- 6.2 Effluent Concentrations -- 6.2.1 Ninety-five (95) percentiles -- 6.2.2 Number of violations -- 6.2.3 Percentage of time plant is in violation -- 6.3 Operational Cost Index -- 6.3.1 Aeration energy -- 6.3.2 Pumping energy -- 6.3.3 Sludge production for disposal -- 6.3.4 External carbon -- 6.3.5 Mixing energy -- 6.3.6 Methane production -- 6.3.7 Heating energy -- 6.4 Controller Assessment -- 6.4.1 Controlled variable tracking -- 6.4.2 Actuator performance -- 6.4.3 Risk-related evaluation criteria -- 6.5 Monitoring Performance Assessment -- 6.6 Evaluation Summary -- Chapter 7: Simulation procedure -- 7.1 BSM1 -- 7.2 BSM1_LT -- 7.3 BSM2 -- Chapter 8: Ring-testing -- 8.1 Steady State Verification -- 8.2 Dynamic Verification -- 8.3 Findings -- Chapter 9: BSM limitations -- 9.1 BSM as a Toolbox -- 9.2 Model Structures -- 9.2.1 Biokinetic models -- 9.2.2 Aeration -- 9.2.3 Solid/Liquid separation models -- 9.2.4 Other models -- 9.3 Model Parameters -- 9.4 Evaluation Criteria -- 9.5 Model Simulation -- 9.6 Application Extension -- 9.7 Conclusion -- Chapter 10: Conclusions and perspectives -- 10.1 Lessons Learned: Development of the Benchmark Platforms -- 10.2 Lessons Learned: Use of the Benchmark Platforms, Verified Process Models and Generic Tools -- 10.2.1 Portability -- 10.2.2 Extensions -- 10.3 Looking Ahead: Future Extensions of the BSM Platforms -- 10.3.1 Temporal extensions -- 10.3.2 Spatial extensions -- 10.3.3 Process extensions -- 10.3.4 Realism of models used in BSM -- 10.3.5 Control strategy extensions -- 10.3.6 Extended evaluation tools -- 10.4 The 'Benchmarking Spirit' -- References -- Appendix A: Model parameters -- Appendix B: Simulation output -- Index. , English
    Weitere Ausg.: ISBN 1-84339-146-5
    Sprache: Englisch
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    UID:
    kobvindex_HPB897838642
    Umfang: 1 online resource (xxi, 142 pages) : , illustrations
    ISBN: 9781780401171 , 1780401175
    Serie: Scientific and technical report series ; no. 23
    Inhalt: Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature for improved and more efficient operation of wastewater treatment plants. Unfortunately, their evaluation and comparison--either practical or based on simulation--is difficult. This is partly due to the variability of the influent, to the complexity of the biological and biochemical phenomena and to the large range of time constants (from a few minutes to several days). The lack of standard evaluation criteria is also a tremendous disadvantage. To really enhance the acceptance of innovative control strategies, such an evaluation needs to be based on a rigorous methodology including a simulation model, plant layout, controllers, sensors, performance criteria and test procedures, i.e. a complete benchmarking protocol. This book is a Scientific and Technical Report produced by the IWA Task Group on Benchmarking of Control Strategies for Wastewater Treatment Plants. The goal of the Task Group includes developing models and simulation tools that encompass the most typical unit processes within a wastewater treatment system (primary treatment, activated sludge, sludge treatment, etc.), as well as tools that will enable the evaluation of long-term control strategies and monitoring tasks (i.e. automatic detection of sensor and process faults). Work on these extensions has been carried out by the Task Group during the past five years, and the main results are summarized in Benchmarking of Control Strategies for Wastewater Treatment Plants. Besides a description of the final version of the already well-known Benchmark Simulation Model no. 1 (BSM1), the book includes the Benchmark Simulation Model no. 1 Long-Term (BSM1_LT)--with focus on benchmarking of process monitoring tasks--and the plant-wide Benchmark Simulation Model no. 2 (BSM2).
    Anmerkung: Cover; Copyright; Contents; Nomenclature; List of technical reports; Preface; Chapter 1: Introduction; 1.1 What is Meant by a 'Benchmark Simulation Model'?; 1.2 What is the Purpose of the Benchmark Simulation Models?; 1.3 Who Should Use the Benchmark Simulation Models?; 1.4 How Should the Benchmark Simulation Models be Used?; 1.5 Who has been Involved in the Development of the Benchmark Simulation Models?; 1.6 How Should this Scientific and Technical Report be Read?; Chapter 2: Benchmark overview; 2.1 Benchmark Simulation Model No. 1; 2.2 Benchmark Simulation Model No. 1 Long-Term. , 2.3 Benchmark Simulation Model No. 22.4 The Benchmark Simulation Model Set; Chapter 3: Benchmark plant description; 3.1 Benchmark Simulation Model No. 1; 3.2 Benchmark Simulation Model No. 1 Long-Term; 3.3 Benchmark Simulation Model No. 2; 3.4 Characteristics Summary; Chapter 4: Benchmark models; 4.1 Influent Modelling; 4.1.1 BSM1 influent; 4.1.2 BSM1_LT and BSM2 influent; 4.2 Unit Process Models; 4.2.1 Activated Sludge Model No. 1 (ASM1); 4.2.2 Anaerobic Digestion Model No. 1 (ADM1); 4.2.3 ASM/ADM interfacing; 4.2.4 Solids separation models; 4.2.5 Reject water storage tank. , 4.3 Sensors and Actuators4.3.1 Sensors; 4.3.2 Actuators; 4.3.3 Faults and failures; 4.4 Inhibition and Toxicity; 4.4.1 Biological processes; 4.4.2 Physical processes; 4.4.3 Modelling inhibitory/toxic substances; 4.5 Risk Assessment Modelling; 4.5.1 Concept; 4.5.2 Application to filamentous bulking; 4.6 Temperature; Chapter 5: Benchmarking of control strategies; 5.1 BSM1 and BSM1_LT Controllers; 5.1.1 Default BSM1 control strategy; 5.1.2 Other BSM1 control handles; 5.1.3 BSM1_LT control strategy; 5.2 BSM2 Controllers; 5.2.1 Default BSM2 control strategy. , 5.2.2 Testing other BSM2 control strategiesChapter 6: Evaluation criteria; 6.1 Effluent and Influent Quality Indices; 6.2 Effluent Concentrations; 6.2.1 Ninety-five (95) percentiles; 6.2.2 Number of violations; 6.2.3 Percentage of time plant is in violation; 6.3 Operational Cost Index; 6.3.1 Aeration energy; 6.3.2 Pumping energy; 6.3.3 Sludge production for disposal; 6.3.4 External carbon; 6.3.5 Mixing energy; 6.3.6 Methane production; 6.3.7 Heating energy; 6.4 Controller Assessment; 6.4.1 Controlled variable tracking; 6.4.2 Actuator performance; 6.4.3 Risk-related evaluation criteria. , 6.5 Monitoring Performance Assessment6.6 Evaluation Summary; Chapter 7: Simulation procedure; 7.1 BSM1; 7.2 BSM1_LT; 7.3 BSM2; Chapter 8: Ring-testing; 8.1 Steady State Verification; 8.2 Dynamic Verification; 8.3 Findings; Chapter 9: BSM limitations; 9.1 BSM as a Toolbox; 9.2 Model Structures; 9.2.1 Biokinetic models; 9.2.2 Aeration; 9.2.3 Solid/Liquid separation models; 9.2.4 Other models; 9.3 Model Parameters; 9.4 Evaluation Criteria; 9.5 Model Simulation; 9.6 Application Extension; 9.7 Conclusion; Chapter 10: Conclusions and perspectives.
    Weitere Ausg.: Print version: Benchmarking of control strategies for wastewater treatment plants ISBN 9781843391463
    Sprache: Englisch
    Schlagwort(e): Electronic books.
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Meinten Sie 9781780401072?
Meinten Sie 9781760461171?
Meinten Sie 9781780401775?
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz