Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Journal of Applied Clinical Medical Physics, Wiley, Vol. 20, No. 2 ( 2019-02), p. 107-113
    Abstract: To compare the dosimetric impact and treatment delivery efficacy of phase‐gated volumetric modulated arc therapy ( VMAT ) vs amplitude‐gated VMAT for stereotactic body radiation therapy ( SBRT ) for lung cancer by using realistic three‐dimensional‐printed phantoms. Methods Four patient‐specific moving lung phantoms that closely simulate the heterogeneity of lung tissue and breathing patterns were fabricated with four planning computed tomography ( CT ) images for lung SBRT cases. The phantoms were designed to be bisected for the measurement of two‐dimensional dose distributions by using EBT3 dosimetry film. The dosimetric accuracy of treatment under respiratory motion was analyzed with the gamma index (2%/1 mm) between the plan dose and film dose measured under phase‐ and amplitude‐gated VMAT . For the validation of the direct usage of the real‐time position management ( RPM ) data for respiratory motion, the relationship between the RPM signal and the diaphragm position was measured by four‐dimensional CT . By using data recorded during the beam delivery of both phase‐ and amplitude‐gated VMAT , the total time intervals were compared for each treatment mode. Results Film dosimetry showed a 5.2 ± 4.2% difference of gamma passing rate (2%/1 mm) on average between the phase‐ vs amplitude‐gated VMAT [77.7% (72.7%–85.9%) for the phase mode and 82.9% (81.4%–86.2%) for the amplitude mode]. For delivery efficiency, frequent interruptions were observed during the phase‐gated VMAT , which stopped the beam delivery and required a certain amount of time before resuming the beam. This abnormality in phase‐gated VMAT caused a prolonged treatment delivery time of 366 s compared with 183 s for amplitude‐gated VMAT . Conclusions Considering the dosimetric accuracy and delivery efficacy between the gating methods, amplitude mode is superior to phase mode for gated VMAT treatment.
    Type of Medium: Online Resource
    ISSN: 1526-9914 , 1526-9914
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2019
    detail.hit.zdb_id: 2010347-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages