Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Catheterization and Cardiovascular Interventions, Wiley, Vol. 98, No. 6 ( 2021-11-15), p. 1047-1056
    Abstract: We aimed to evaluate the determinants of visual‐functional mismatches between quantitative coronary angiography (QCA) and the quantitative flow ratio (QFR). Background The fractional flow reserve (FFR) has been established as a method to estimate the functional stenosis severity of coronary artery disease and to optimize decision‐making for revascularization. The QFR is a novel angiography‐derived computational index that can estimate the FFR without pharmacologically induced hyperemia or the use of pressure wire. Methods A total of 504 de novo intermediate‐to‐severe stable lesions that underwent angiographic and physiological assessments were analyzed. All lesions were divided into four groups based on the significance of visual (QCA‐diameter stenosis [DS]  〉  50% and ≤ 50%) and functional (QFR ≤ 0.80 and  〉  0.80) stenosis severity. Patient characteristics, angiographic findings, and physiological indices were compared. Results One‐hundred seventy‐eight lesions (35.3%) showed discordant visual‐functional assessments; mismatch (QCA‐DS  〉  50% and QFR  〉  0.80) in 75 lesions (14.9%) and reverse mismatch (QCA‐DS ≤ 50% and QFR ≤ 0.80) in 103 lesions (20.4%), respectively. Reverse mismatch was associated with non‐diabetes, lower ejection fraction, higher Duke jeopardy score, and lower coronary flow reserve (CFR). Mismatch was associated with smaller QCA‐DS, larger reference diameter, shorter lesion length, lower Duke jeopardy score, and higher CFR. Lesion location and microcirculatory resistance was not associated with the prevalence of mismatches. Reverse mismatch group had the higher prevalence of discordant decision‐makings between QFR and FFR than the other three groups. Conclusions The CFR and subtended myocardial mass were predictors of visual‐functional mismatches between QCA‐DS and the QFR. Caution should be exercised in lesions showing QCA‐DS/QFR reverse mismatch.
    Type of Medium: Online Resource
    ISSN: 1522-1946 , 1522-726X
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2021
    detail.hit.zdb_id: 2001555-0
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages