Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: ESC Heart Failure, Wiley, Vol. 7, No. 6 ( 2020-12), p. 4377-4383
    Abstract: The aim of this study is to report heart failure hospitalization (HFH) rates and associated costs within 12 months following implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT‐D) device replacement or upgrade from ICD to CRT‐D. Methods and results The DEtect long‐term COmplications after icD rEplacement (DECODE) was a prospective, single‐arm, multicentre cohort study that explored complications in ICD/CRT‐D recipients. All clinical and survival data at 12 months were prospectively analysed. For each adjudicated HFH, admission and discharge dates and ICD‐9‐CM diagnosis and procedure codes were recorded. The reimbursement for each HFH was calculated for each diagnosis‐related group code. Between 2013 and 2015, 983 patients (mean age 71 years, male 76%, mean left ventricular ejection fraction 35%, and New York Heart Association Class I/II 75.6%) were enrolled. Patients underwent device replacement (900; 91.6%, 446 ICD/454 CRT‐D) or ICD upgrade to CRT‐D (83; 8.4%). Post‐replacement hospitalizations occurred in 220 patients, with the primary discharge diagnosis identifying cardiovascular causes in 175 patients (80%). Fifty‐five (5.6%) patients experienced at least one HFH. Overall, 91 HFH events occurred (9.6% event rate, 95% confidence interval: 7.7–11.7) in 70 patients; 66 (6.7%) patients died, 40 (60.6%) of cardiovascular causes. The HFH rate was significantly higher following upgrades, and the occurrence of HFH was associated with an 11‐fold increased mortality risk (95% confidence interval: 5.9–20.5, P   〈  0.0001). Medical diagnosis‐related group accounted for 91.2% of HFH; the mean cost per HFH was €5662 ± 9497, and the mean cost per patient was €9369 ± 12 687. On multivariate analysis, predictors of HFH were atrial fibrillation, chronic kidney disease, and all‐cause hospitalization within 30 days prior to the procedure. Conclusions In the DECODE registry, HFH and mortality rates in the year following ICD/CRT‐D replacement or upgrade were low. In this particular subset, underlying cardiac disease was the main driver of HFH, mortality, and higher healthcare expenditures.
    Type of Medium: Online Resource
    ISSN: 2055-5822 , 2055-5822
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2020
    detail.hit.zdb_id: 2814355-3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages