Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Journal of Magnetic Resonance Imaging, Wiley, Vol. 45, No. 3 ( 2017-03), p. 804-812
    Abstract: To summarize our single‐center safety experience with the off‐label use of ferumoxytol for magnetic resonance imaging (MRI) and to compare the effects of ferumoxytol on monitored physiologic indices in patients under anesthesia with those of gadofosveset trisodium. Materials and Methods Consecutive patients who underwent ferumoxytol‐enhanced (FE) MRI exams were included. Adverse events (AEs) were classified according to the Common Terminology Criteria for Adverse Events v4.0. In a subgroup of patients examined under general anesthesia, recording of blood pressure, heart rate, oxygen saturation, and end‐tidal CO 2 was performed. A comparable group of 23 patients who underwent gadofosveset‐enhanced (GE) MRI under anesthesia with similar monitoring was also analyzed. Results In all, 217 unique patients, ages 3 days to 94 years, underwent FE‐MRI. No ferumoxytol‐related severe, life‐threatening, or fatal AEs occurred acutely or at follow‐up. Two patients developed ferumoxytol‐related nausea. Between‐group (FE‐ vs. GE‐MRI) comparisons showed no statistical difference in heart rate ( P  = 0.69, 95% confidence interval [CI] 96–113 bpm), mean arterial blood pressure (MAP) ( P  = 0.74, 95% CI 44–52 mmHg), oxygen saturation ( P  = 0.76, 95% CI 94–98%), and end‐tidal CO 2 ( P  = 0.73, 95% CI 31–37 mmHg). No significant change in MAP ( P  = 0.12, 95% CI 50–58 mmHg) or heart rate ( P  = 0.25, 95% CI 91–105 bpm) was noted between slow infusion of ferumoxytol ( n  = 113) vs. bolus injection ( n  = 104). Conclusion In our single‐center experience, no serious AEs occurred with the diagnostic use of ferumoxytol across a wide spectrum of age, renal function, and indications. Because of the limited sample size, firm conclusions cannot be drawn about the generalizability of our results. Thus, vigilance and monitoring are recommended to mitigate potential rare adverse reactions. Level of Evidence: 2 J. Magn. Reson. Imaging 2017;45:804–812.
    Type of Medium: Online Resource
    ISSN: 1053-1807 , 1522-2586
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2017
    detail.hit.zdb_id: 1497154-9
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages