Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Online-Ressource
    Online-Ressource
    Ovid Technologies (Wolters Kluwer Health) ; 2016
    In:  Liver Transplantation Vol. 22, No. 4 ( 2016-04), p. 468-475
    In: Liver Transplantation, Ovid Technologies (Wolters Kluwer Health), Vol. 22, No. 4 ( 2016-04), p. 468-475
    Kurzfassung: Prolonged prothrombin time (PT) and its ratio are routinely used for the assessment of candidates for liver transplantation (LT), but intraoperative coagulation management of transfusion is hindered by its long turnaround time. Abnormal reaction time (R time) on thromboelastography (TEG) or clotting time (CT) of rotational thromboelastometry (ROTEM) are presumably an alternative, but there is a paucity of clinical data on abnormal R time/CT values compared to PT during LT. After receiving institutional review board approval and informed consent, we obtained blood samples from 36 LT patients for international normalized ratio (INR), factor (F) X level, and viscoelastic tests (EXTEM/INTEM and kaolin/rapid TEG) at baseline and 30 minutes after graft reperfusion. Receiver operating characteristic (ROC) curves were calculated for INR  〉  1.5 and viscoelastic R time/CT thresholds to assess the ability to diagnose FX deficiency at the moderate ( 〈 50%) or severe ( 〈 35%) level. The FX deficiency data were calculated using cutoff values of INR ( 〉 1.5) and abnormal R time/CT for TEG and ROTEM. Tissue factor (TF)–activated INR and EXTEM‐CT performed well in diagnosing FX below 50%, but rapid TEG with combined TF and kaolin activators failed. Improved performance of INTEM‐CT in diagnosing FX below 35% underlies multifactorial deficiency involving both intrinsic and common pathways. In conclusion, the differences among different viscoelastic tests and clinical situations should be carefully considered when they are used to guide transfusion during LT.
    Materialart: Online-Ressource
    ISSN: 1527-6465 , 1527-6473
    Sprache: Englisch
    Verlag: Ovid Technologies (Wolters Kluwer Health)
    Publikationsdatum: 2016
    ZDB Id: 2002186-0
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz