    In: Medical Physics, Wiley, Vol. 46, No. 10 ( 2019-10), p. 4346-4355
    Abstract: To use four‐dimensional (4D) dose accumulation based on deformable image registration (DIR) to assess dosimetric uncertainty in lung stereotactic body radiation therapy (SBRT) treatment planning. A novel concept, the Evaluation Target Volume (ETV), was introduced to achieve this goal. Methods The internal target volume (ITV) approach was used for treatment planning for 11 patients receiving lung SBRT. Retrospectively, 4D dose calculation was done in Pinnacle v9.10. Total dose was accumulated in the reference phase using DIR with MIM. DIR was validated using landmarks introduced by an expert radiation oncologist. The 4D and three‐dimensional (3D) dose distributions were compared within the gross tumor volume (GTV) and the planning target volume (PTV) using the D 95 and D min (calculated as D min,0.035cc ) metrics. For lung involvement, the mean dose and V 20 , V 10 , and V 5 were used in the 3D to 4D dose comparison, and D max (D 0.1cc ) was used for all other organs at risk (OAR). The new evaluation target volume (ETV) was calculated by expanding the GTV in the reference phase in order to include geometrical uncertainties of the DIR, interobserver variability in the definition of the tumor, and uncertainties of imaging and delivery systems. D 95 and D min,0.035cc metrics were then calculated on the basis of the ETV for 4D accumulated dose distributions, and these metrics were compared with those calculated from the PTV for 3D planned dose distributions. Results The target registration error (TRE) per spatial component was below 0.5 ± 2.1mm for all our patients. For five patients, dose degradation above 2% ( 〉 4% in 2 patients) was found in the PTV after 4D accumulation and attributed to anatomical variations due to breathing. Comparison of D 95 and D min,0.035cc metrics showed that the ETV (4D accumulated dose) estimated substantially lower coverage than the PTV (3D planning dose): in six out of the 11 cases, and for at least for one of the two metrics, coverage estimated by ETV was at least 5% lower than that estimated by PTV. Furthermore, the ETV approach revealed hot and cold spots within its boundaries. Conclusions A workflow for 4D dose accumulation based on DIR has been devised. Dose degradation was attributed to respiratory motion. To overcome limitations in the PTV for the purposes of evaluating DIR‐based 4D accumulated dose distributions, a new concept, the ETV, was proposed. This concept appears to facilitate more reliable dose evaluation and a better understanding of dosimetric uncertainties due to motion and deformation.
    Type of Medium: Online Resource
    ISSN: 0094-2405 , 2473-4209
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2019
    detail.hit.zdb_id: 1466421-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages