Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Magnetic Resonance in Medicine, Wiley, Vol. 90, No. 5 ( 2023-11), p. 1844-1858
    Abstract: To enable free‐breathing and high isotropic resolution liver quantitative susceptibility mapping (QSM) using 3D multi‐echo UTE cones acquisition and respiratory motion‐resolved image reconstruction. Methods Using 3D multi‐echo UTE cones MRI, a respiratory motion was estimated from the k‐space center of the imaging data. After sorting the k‐space data with estimated motion, respiratory motion state‐resolved reconstruction was performed for multi‐echo data followed by nonlinear least‐squares fitting for proton density fat fraction (PDFF), , and fat‐corrected B 0 field maps. PDFF and B 0 field maps were subsequently used for QSM reconstruction. The proposed method was compared with motion‐averaged (gridding) reconstruction and conventional 3D multi‐echo Cartesian MRI in moving gadolinium phantom and in vivo studies. Region of interest (ROI)‐based linear regression analysis was performed on these methods to investigate correlations between gadolinium concentration and QSM in the phantom study and between and QSM in in vivo study. Results Cones with motion‐resolved reconstruction showed sharper image quality compared to motion‐averaged reconstruction with a substantial reduction of motion artifacts in both moving phantom and in vivo studies. For ROI‐based linear regression analysis of the phantom study, susceptibility values from cones with motion‐resolved reconstruction ( = 0.31  0.05,  = 0.999) and Cartesian without motion ( = 0.32 0.04,  = 1.000) showed linear relationships with gadolinium concentrations and showed good agreement with each other. For in vivo, motion‐resolved reconstruction showed higher goodness of fit ( = 0.00261  0.524,  = 0.977) compared to motion‐averaged reconstruction ( = 0.0021  0.572, = 0.723) in ROI‐based linear regression analysis between and QSM. Conclusion Feasibility of free‐breathing liver QSM was demonstrated with motion‐resolved 3D multi‐echo UTE cones MRI, achieving high isotropic resolution currently unachievable in conventional Cartesian MRI.
    Type of Medium: Online Resource
    ISSN: 0740-3194 , 1522-2594
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2023
    detail.hit.zdb_id: 1493786-4
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages