Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Springer Science and Business Media LLC ; 2023
    In:  European Archives of Oto-Rhino-Laryngology Vol. 280, No. 5 ( 2023-05), p. 2149-2154
    In: European Archives of Oto-Rhino-Laryngology, Springer Science and Business Media LLC, Vol. 280, No. 5 ( 2023-05), p. 2149-2154
    Abstract: A narrow bony internal auditory canal (IAC) may be associated with a hypoplastic cochlear nerve and poorer hearing performances after cochlear implantation. However, definitions for a narrow IAC vary widely and commonly, qualitative grading or two-dimensional measures are used to characterize a narrow IAC. We aimed to refine the definition of a narrow IAC by determining IAC volume in both control patients and patients with inner ear malformations (IEMs). Methods In this multicentric study, we included high-resolution CT (HRCT) scans of 128 temporal bones (85 with IEMs: cochlear aplasia, n  = 11; common cavity, n  = 2; cochlear hypoplasia type, n  = 19; incomplete partition type I/III, n  = 8/8; Mondini malformation, n  = 16; enlarged vestibular aqueduct syndrome, n  = 19; 45 controls). The IAC diameter was measured in the axial plane and the IAC volume was measured by semi-automatic segmentation and three-dimensional reconstruction. Results In controls, the mean IAC diameter was 5.5 mm (SD 1.1 mm) and the mean IAC volume was 175.3 mm 3 (SD 52.6 mm 3 ). Statistically significant differences in IAC volumes were found in cochlear aplasia (68.3 mm 3 , p   〈  0.0001), IPI (107.4 mm 3 , p  = 0.04), and IPIII (277.5 mm 3 , p  = 0.0004 mm 3 ). Inter-rater reliability was higher in IAC volume than in IAC diameter (intraclass correlation coefficient 0.92 vs. 0.77). Conclusions Volumetric measurement of IAC in cases of IEMs reduces measurement variability and may add to classifying IEMs. Since a hypoplastic IAC can be associated with a hypoplastic cochlear nerve and sensorineural hearing loss, radiologic assessment of the IAC is crucial in patients with severe sensorineural hearing loss undergoing cochlear implantation.
    Type of Medium: Online Resource
    ISSN: 0937-4477 , 1434-4726
    RVK:
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2023
    detail.hit.zdb_id: 1459042-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages