    In: Alzheimer's & Dementia, Wiley, Vol. 9, No. 3 ( 2013-05), p. 251-261
    Abstract: The cerebrospinal fluid (CSF) biomarkers amyloid beta 1–42, total tau, and phosphorylated tau are used increasingly for Alzheimer's disease (AD) research and patient management. However, there are large variations in biomarker measurements among and within laboratories. Methods Data from the first nine rounds of the Alzheimer's Association quality control program was used to define the extent and sources of analytical variability. In each round, three CSF samples prepared at the Clinical Neurochemistry Laboratory (Mölndal, Sweden) were analyzed by single‐analyte enzyme‐linked immunosorbent assay (ELISA), a multiplexing xMAP assay, or an immunoassay with electrochemoluminescence detection. Results A total of 84 laboratories participated. Coefficients of variation (CVs) between laboratories were around 20% to 30%; within‐run CVs, less than 5% to 10%; and longitudinal within‐laboratory CVs, 5% to 19%. Interestingly, longitudinal within‐laboratory CV differed between biomarkers at individual laboratories, suggesting that a component of it was assay dependent. Variability between kit lots and between laboratories both had a major influence on amyloid beta 1–42 measurements, but for total tau and phosphorylated tau, between‐kit lot effects were much less than between‐laboratory effects. Despite the measurement variability, the between‐laboratory consistency in classification of samples (using prehoc‐derived cutoffs for AD) was high ( 〉 90% in 15 of 18 samples for ELISA and in 12 of 18 samples for xMAP). Conclusions The overall variability remains too high to allow assignment of universal biomarker cutoff values for a specific intended use. Each laboratory must ensure longitudinal stability in its measurements and use internally qualified cutoff levels. Further standardization of laboratory procedures and improvement of kit performance will likely increase the usefulness of CSF AD biomarkers for researchers and clinicians.
    Type of Medium: Online Resource
    ISSN: 1552-5260 , 1552-5279
    Language: English
    Publisher: Wiley
    Publication Date: 2013
    detail.hit.zdb_id: 2201940-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages