In:
Acta Acustica, EDP Sciences, Vol. 5 ( 2021), p. 27-
Abstract:
The ISO 3382-3 standard uses the measurable sound pressure based parameters D 2,S and L p ,A,S,4 m to describe the acoustic properties of open-plan offices. As yet however, no treatment of the measurement uncertainty of these parameters according to the Guide to the expression of Uncertainty in Measurement (GUM) is to be found in the peer-reviewed literature. This technical note therefore describes how the measurement uncertainty can be declared according to GUM. The mathematical framework presented here can be used and expanded by other laboratories to derive their own uncertainty estimates. It is also applied in this document to 44 measurements yielding combined uncertainties for D 2,S of 0.55 dB ≤ $ {\sigma }_{c,{D}_{2,\mathrm{S}}}$ ≤ 0.67 dB and for L p ,A,S,4 m of 0.19 dB ≤ $ {\sigma }_{c,{L}_{p,\mathrm{A},\mathrm{S},4\enspace \mathrm{m}}}$ ≤ 0.83 dB. The implications of this result are discussed with regard to limit values in technical regulations.
Type of Medium:
Online Resource
ISSN:
2681-4617
DOI:
10.1051/aacus/2021022
Language:
English
Publisher:
EDP Sciences
Publication Date:
2021
detail.hit.zdb_id:
3021733-7