Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    In: Ultraschall in der Medizin - European Journal of Ultrasound, Georg Thieme Verlag KG, Vol. 41, No. 05 ( 2020-10), p. 526-533
    Kurzfassung: Purpose Clinically significant portal hypertension (CSPH) is responsible for most of the complications in patients with cirrhosis. Liver stiffness (LS) measurement by vibration-controlled transient elastography (VCTE) is currently used to evaluate CSPH. Bi-dimensional shear wave elastography from General Electric (2D-SWE.GE) has not yet been validated for the diagnosis of PHT. Our aims were to test whether 2D-SWE.GE-LS is able to evaluate CSPH, to determine the reliability criteria of the method and to compare its accuracy with that of VCTE-LS in this clinical setting. Materials and Methods Patients with chronic liver disease referred to hepatic catheterization (HVPG) were consecutively enrolled. HVPG and LS by both VCTE and 2D-SWE.GE were performed on the same day. The diagnostic performance of each LS method was compared against HVPG and between each other. Results 2D-SWE.GE-LS was possible in 123/127 (96.90 %) patients. The ability to record at least 5 LS measurements by 2D-SWE.GE and IQR  〈  30 % were the only features associated with reliable results. 2D-SWE.GE-LS was highly correlated with HVPG (r = 0.704; p  〈  0.0001), especially if HVPG 〈  10 mmHg and was significantly higher in patients with CSPH (15.52 vs. 8.14 kPa; p  〈  0.0001). For a cut-off value of 11.3 kPa, the AUROC of 2D-SWE.GE-LS to detect CSPH was 0.91, which was not inferior to VCTE-LS (0.92; p = 0.79). The diagnostic accuracy of LS by 2D-SWE.GE-LS to detect CSPH was similar with the one of VCTE-LS (83.74 % vs. 85.37 %; p = 0.238). The diagnostic accuracy was not enhanced by using different cut-off values which enhanced the sensitivity or the specificity. However, in the subgroup of compensated patients with alcoholic liver disease, 2D-SWE.GE-LS classified CSPH better than VCTE-LS (93.33 % vs. 85.71 %, p = 0.039). Conclusion 2D-SWE.GE-LS has good accuracy, not inferior to VCTE-LS, for the diagnosis of CSPH.
    Materialart: Online-Ressource
    ISSN: 0172-4614 , 1438-8782
    Sprache: Englisch
    Verlag: Georg Thieme Verlag KG
    Publikationsdatum: 2020
    ZDB Id: 2028670-3
    SSG: 12
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz