Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Online-Ressource
    Online-Ressource
    Georg Thieme Verlag KG ; 2019
    In:  Journal of Neurological Surgery Part A: Central European Neurosurgery Vol. 80, No. 02 ( 2019-03), p. 116-121
    In: Journal of Neurological Surgery Part A: Central European Neurosurgery, Georg Thieme Verlag KG, Vol. 80, No. 02 ( 2019-03), p. 116-121
    Kurzfassung: Background Insertion of a frontal external ventricular drain (EVD) is a common emergency procedure in neurosurgery. Malpositioning of the EVD and/or triggering a new intracerebral or intraventricular hemorrhage (nICVH) are typical complications. The standard procedure (SP) uses a tape measure to identify the Kocher's point for placement of a frontal burr hole. A faster alternative to determine the correct position is the freehand technique (FHT). This study compared both techniques with regard to the correct positioning of the EVD tip and the induction catheter-induced nICVH. Methods We performed a retrospective analysis of patients who required an EVD for acute or chronic hydrocephalus between January 2013 and March 2014. The study consisted of two groups. In the first group, EVDs were placed with the FHT. In the second group the SP was used. Postoperative computed tomography scans were analyzed regarding correct positioning of the ventricular catheter, malpositioning of the tip of the EVD using a 4-point-scale, and evidence for catheter-induced nICVH. Results A total of 95 patients could be included. The FHT was performed in 43 cases and the SP in 52 cases. No significant differences between the two groups were found regarding the correct position of the EVD tip (p = 0.38) and nICVH (p = 0.12). There was no significant difference in malpositioning of the EVD tip between the groups (p = 0.34). Conclusion Our results show no significant differences between the two methods with regard to correct position, malpositioning, and nICVH. Thus we conclude that the FHT is a fast, safe, and effective alternative to the SP.
    Materialart: Online-Ressource
    ISSN: 2193-6315 , 2193-6323
    Sprache: Englisch
    Verlag: Georg Thieme Verlag KG
    Publikationsdatum: 2019
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz