The required alignment tolerances and surface roughness for unit lens elements in a compound refractive lens (CRL) for x rays are discussed. Contrary to what one might expect and what has been stated in the patent literature, alignment tolerances are large and for typical parameter values the effect of misalignment is minor. For a parabolic lens the focusing properties of the CRL are unaltered by misalignment and there is a small increase in absorption. For a lens with spherical aberration, there is a slight change in focal length, a minor translation of the image, and a small increase in absorption. This article also shows that lens gain is not appreciably reduced if the phase shift that is introduced by the roughness is limited to ±π/4 or if the transverse period of the roughness exceeds a specified value. The CRL can benefit from a managed misalignment of the elements to reduce the phase error introduced by surface imperfections of the lens.