Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Oxford University Press (OUP) ; 2023
    In:  Aesthetic Surgery Journal Vol. 43, No. 10 ( 2023-09-14), p. 1114-1123
    In: Aesthetic Surgery Journal, Oxford University Press (OUP), Vol. 43, No. 10 ( 2023-09-14), p. 1114-1123
    Abstract: Although a portable 3-dimensional (3D) imaging system has been used for periocular measurement analysis, this system has yet to be tested and validated for periocular area and volume measurements. Objectives The aim of this study was to define the upper eyelid and upper eyelid fold region through a modified landmark strategy and validate a portable 3D imaging system for area and volume measurements in this periocular region. Methods Eighty-one healthy adult Caucasians underwent 3D facial imaging with the VECTRA M3 (static) and VECTRA H2 (portable) 3D imaging systems (Canfield Scientific, Inc., Parsippany, NJ). Subsequently, the upper eyelid and upper eyelid fold regions were selected according to a modified landmark localization strategy. Direct measurements of area and volume were performed to assess intrarater, interrater, intramethod, and intermethod reliability, and to compare the agreement between the 2 devices. Results The VECTRA M3 and H2 showed high reliability on upper eyelid area measurements. Excellent intra-, inter-, and intramethod reliability agreements were observed in intraclass correlation coefficient; very good agreement in intrarater reliability was observed in the relative error of measurement (REM) and relative technical error of measurement (rTEM); and good inter- and intramethod reliability were observed in the REM and rTEM. For area measurement of the upper eyelid fold, the intrarater, interrater, and intramethod reliability of the M3 was lower than that of the H2. Both systems had poor intrarater, interrater, and intramethod reliability for volume measurements in the upper eyelid and upper eyelid fold region. Conclusions This new portable 3D imaging system achieved excellent or very good reliability values for standardized direct measurements of the upper eyelid and upper eyelid fold region, although volume measurements seem less reliable.
    Type of Medium: Online Resource
    ISSN: 1090-820X , 1527-330X
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2023
    detail.hit.zdb_id: 2048788-5
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages