Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2000
    In:  Anesthesiology Vol. 92, No. 6 ( 2000-06-01), p. 1646-1652
    In: Anesthesiology, Ovid Technologies (Wolters Kluwer Health), Vol. 92, No. 6 ( 2000-06-01), p. 1646-1652
    Abstract: Erythrocytes are transfused to prevent or treat inadequate oxygen delivery resulting from insufficient hemoglobin concentration. Previous studies failed to find evidence of inadequate systemic oxygen delivery at a hemoglobin concentration of 5 g/dl. However, in those studies, sensitive, specific measures of critical organ function were not used. This study tested the hypothesis that acute severe decreases of hemoglobin concentration alters human cognitive function. Methods Nine healthy volunteers, age 29 +/- 5 yr (mean +/- SD), were tested with verbal memory and standard, computerized neuropsychologic tests before and after acute isovolemic reduction of their hemoglobin to 7, 6, and 5 g/dl and again after transfusion of their autologous erythrocytes to return their hemoglobin concentration to 7 g/dl. To control for duration of the experiment, each volunteer also completed the same tests on a separate day, without alteration of hemoglobin, at times of the day approximately equivalent to those on the experimental day. Results No test showed any change in reaction time or error rate at hemoglobin concentration of 7 g/dl compared with the data at the baseline hemoglobin concentration of 14 g/dl. Reaction time, but not error rate, for horizontal addition and digit-symbol substitution test (DSST) increased at hemoglobin 6 g/dl (mean horizontal addition, 19%; 95% confidence interval [CI], 4-34%; mean DSST, 10%; 95% CI, 4-17%) and further at 5 g/dl (mean horizontal addition, 43%; 95% CI, 6-79%; mean DSST, 18%; 95% CI, 4-31%). Immediate and delayed memory was degraded at hemoglobin 5 g/dl but not at 6 g/dl. Return of hemoglobin to 7 g/dl returned all tests to baseline, except for the DSST, which significantly improved, and returned to baseline the following morning after transfusion of all autologous erythrocytes. Conclusion Acute reduction of hemoglobin concentration to 7 g/dl does not produce detectable changes in human cognitive function. Further reduction of hemoglobin level to 6 and 5 g/dl produces subtle, reversible increases in reaction time and impaired immediate and delayed memory. These are the first prospective data to demonstrate subtle degraded human function with acute anemia of hemoglobin concentrations of 6 and 5 g/dl. This reversibility of these decrements with erythrocyte transfusion suggests that our model can be used to test the efficacy of erythrocytes, oxygen therapeutics, or other treatments for acute anemia.
    Type of Medium: Online Resource
    ISSN: 0003-3022
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2000
    detail.hit.zdb_id: 2016092-6
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages