Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Online-Ressource
    Online-Ressource
    Ovid Technologies (Wolters Kluwer Health) ; 2017
    In:  Clinical Spine Surgery: A Spine Publication Vol. 30, No. 5 ( 2017-06), p. E628-E632
    In: Clinical Spine Surgery: A Spine Publication, Ovid Technologies (Wolters Kluwer Health), Vol. 30, No. 5 ( 2017-06), p. E628-E632
    Kurzfassung: Retrospective clinical study. Objective: To evaluate the clinical outcome of patients who had undergone occipitocervical (OC) fusion using pedicle screws and rods over a minimum 5-year follow-up. Summary of Background Data: Few studies have evaluated occipitocervical (OC) fusion using pedicle screws and rods for long-term follow-up. Methods: Twenty-seven consecutive patients treated underwent posterior OC fusion using pedicle screws and rods over a minimum 5-year follow-up. The Modified McCormick scale to grade a patient’s functional status and the Japanese Orthopaedic Association (JOA) scoring system were used to evaluate preoperative and postoperative neurological function. We assessed fusion by both direct and indirect evidence; bony trabeculae at the graft-recipient interface on lateral cervical radiographs and sagittal computed tomography reconstruction was considered direct evidence of union. Results: The mean follow-up period was 7.2 years (5–14 y). JOA scores were 8.1±3.8 before surgery and 11.7±3.7 at the final follow-up. The recovery rate calculated from the JOA scores was 42.0±30.0%. Functional status did improve at least 1 grade according to the modified McCormick scale in 18 patients (66.7%). There was no deterioration at the final follow-up. There were postoperative implant-related complications in 8 patients (29.6%): loosening of pedicle screws in 2, rod breakage in 2, plate breakage in 1, screw breakage in 1, pullout of pedicle screws in 1, and wiring induced myelopathy in 1 patient. The average duration between surgery and implant failure was 31.2 months (12–60 mo) except for 2. Conclusions: Sufficient bone grafting, proper decortication of the bone bed, using thicker and high stiffness rods, and ultra-high molecular weight polyethylene tape as a fixation or reinforcement of implant may help prevent implant failure.
    Materialart: Online-Ressource
    ISSN: 2380-0186
    Sprache: Englisch
    Verlag: Ovid Technologies (Wolters Kluwer Health)
    Publikationsdatum: 2017
    ZDB Id: 2849652-8
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie auf den KOBV Seiten zum Datenschutz