Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2022
    In:  Therapeutic Drug Monitoring Vol. 44, No. 5 ( 2022-10), p. 659-664
    In: Therapeutic Drug Monitoring, Ovid Technologies (Wolters Kluwer Health), Vol. 44, No. 5 ( 2022-10), p. 659-664
    Abstract: Ultrasound is valuable in tight control algorithms for Crohn's disease (CD). However, the correlation between ultrasonographic response and anti–tumor necrosis factor (TNF) drug levels remains unknown. Elucidating this correlation would be helpful in optimizing the use of anti-TNF drugs. Thus, the authors aimed to investigate this correlation. Methods: Between June 2020 and June 2021, all patients with CD who completed anti-TNF induction therapy were retrospectively included. Ultrasound was performed at week 0 and week 14, and proactive therapeutic drug monitoring of anti-TNF drugs was performed at week 14. The receiver operating characteristic (ROC) curve was used in the correlation analysis. Results: Ninety-two patients (60 treated with infliximab and 32 with adalimumab) were included. At week 14, an ultrasonographic response was detected in 43 patients. Patients with ultrasonographic response had significantly higher median drug levels (5.9 mcg/mL for infliximab; 18.2 mcg/mL for adalimumab) than those without (0.9 mcg/mL for infliximab, P 〈 0.001; 4.8 mcg/mL for adalimumab, P 〈 0.001). The ROC curve showed a significant correlation between ultrasonographic response and anti-TNF drug levels (area under the curve = 0.79 for infliximab, P 〈 0.001; area under the curve = 0.86 for adalimumab, P 〈 0.001). The optimal cut-off values for infliximab and adalimumab correlated with ultrasonographic response were 5.0 and 10.5 mcg/mL, respectively. An incremental increase was observed in ultrasonographic response with higher anti-TNF drug levels. Conclusions: Higher anti-TNF drug levels are associated with an increased likelihood of ultrasonographic response in patients with CD.
    Type of Medium: Online Resource
    ISSN: 0163-4356
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2048919-5
    SSG: 15,3
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. Further information can be found on the KOBV privacy pages